Catalog excerpts
Specifi cation data www.systemair.com Topvex Rotating or Cross fl ow heat exchanger
Open the catalog to page 12 Topvex Topvex SR, TR, SX and TX is a series of effi cient ventilation units designed for offi ces, shops, schools, daycare centres or similar premises. The units are especially designed to meet the coming energy requirements and have therefore a very low energy use. To simplify the installation and commissioning the units are included with control system and pre-confi gured. It could not be easier! Topvex are delivered pre-programmed, tested and ready for installation. Connect the Topvex unit to the duct system, connect any external components, connect the main supply, set the time and...
Open the catalog to page 23 Easy electrical connections and service All electrical connections are done at the same terminal block, with clear markings. General Topvex units are delivered enclosed in plastic and mounted on pallets. The units are fully connected internally. The automatic control system is preset and has been test-run at the factory. Any cables to external components should be connected to terminals in the connection space. The same applies to valve actuators for heating coils. Measurement at Systemair's Development Centre Topvex are measured and tested at Systemair's Development Centre. The air...
Open the catalog to page 34 Components Fans Topvex has effective plug-fans with maintenance- free external rotormotors. The fans have been selected to provide optimal operation in respect of air volume, sound level and effi ciency. The units have electronically commutated motors, so called EC-motors with very high effi ciency. The EC motors are controlled in steps via the control unit. To facilitate maintenance and servicing the fans have quick release connections for the electrical cables. Heat exchanger – Rotating The rotating heat exchanger is nonhygroscopic and belt driven. A spare belt is mounted on the rotor...
Open the catalog to page 45 Filters The units are delivered with bag fi lters as standard. Both of the fi lters are placed before the heat exchanger, to keep the exchanger clean. The fi lters are mounted in guide rails that facilitate insertion and removal for inspection and service. The guide rails are spring mounted and fi tted with sealing strips to provide optimal sealing against the fi lters. Filter class F7 on supply air and F5 on extract air are used as standard. Filter monitoring is done via the built-in timer (Standard controller) or via built in pressure transmitters measuring the fi lter pressure drop...
Open the catalog to page 57 Display The illuminated display has 4 rows of 20 characters each and 20 different languages are available. Arrows are used to simplify the usage. The background illumination is normally switched off, and is activated by pushing one of the buttons. The illumination is then switched off again after a period of inactivity. LEDs The alarm LED is marked with a symbol. The ”write enable” LED is marked with a symbol. Push-Buttons All functions can be set (confi gured) by using the information in the display and the push-buttons on the controller. Standard & Advanced control Systemair are using...
Open the catalog to page 7Topvex.indd tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:12.00pt "Arial", sans-serif; } .font2 { font:15.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Times New Roman", serif; } ^^Systemair Rgulations S = standard settings P=possible settings C=choose when ordering O = option SR03, 04, 06 SX03, 04, 06 SR07 E, 09 E, 11 E TR03, 04, 06 TX03, 04, 06 TR09, 12, 15 Controller Standard, E17S Standard, E17S Advanced, E28 Control Panel Remote with 10 meter cable S S S Repeater When more than 10 meter between unit and control panel O...
Open the catalog to page 810 Topvex TR Topvex TX TX03-04 TR03-04 TR06 TR09-15 TX06 T – Top connection R – Rotating heat exchanger X – Cross fl ow heat exchanger Topvex TR/TX is a “Plug and play” air handling unit with a modern design intended for ventilating offi ces, day-care centres or used as zone ventilation in larger buildings e.g. schools. Top-connection of the air-ducts minimise the “Footprint” of the unit. To meet the new restricted energy requirements with low SFP (Specifi c Fan Power) Topvex is equipped with EC fan motors. EC-motors consume an average of 30% less energy than AC motors. In some...
Open the catalog to page 1011 Explanatory sketch TR/TX Topvex TR03-06 RM OS SS ETS HE SF EF FPS RG UC DO DEH WVA WV ET OT UC Unit control SF Supply fan EF Extract Fan SS Supply air temp. sensor ETS Extract air temp. sensor OS Outdoor air temp. sensor OT Overheating thermostat ET Emergency thermostat FPS Frost protection temp. sensor WVA Water valve actuator (accessories) WV Water valve (accessories) HE Heat exchanger RM Rotor motor RG Rotor guard DO Damper outdoor air (accessories) DEH Damper exhaust air (accessories) UC Unit control FPS Frost protection temp. sensor SF Supply fan WVA Water valve actuator (accessory)...
Open the catalog to page 1123 Topvex TR09 Topvex TR12 Topvex TR15 Repeater 1 E0-R230K E0-R230K E0-R230K E-Tool cable ETC ETC ETC Shut-off damper EFD 70-30 EFD 80-35 EFD 100-35 Valve actuator AQM AQM AQM Valve, 2-way STV15-2.1 STV15-2.7 STV20-4.2 Valve, 3-way STR15-2,7 STR20-4,2 STR20-5,6 Cooling battery, water PGK 70-40 PGK 80-50 PGK 100-50 Cooling battery, DX coil DXRE 70-40 DXRE 80-50 DXRE 100-50 Duct sensor TG-KH/PT1000 TG-KH/PT1000 TG-KH/PT1000 Silencer LDR 70-40 LDR 80-50 LDR 100-50 Timer T 120 T 120 T 120 Room temp sensor TG-R5/PT1000 TG-R5/PT1000 TG-R5/PT1000 Outdoor sensor, wall mount TG-UH7PT1000...
Open the catalog to page 2324 • Model: TR03, TR04, TR06 • Heating coil: electric = EL, water = HW Available power: TR03 EL: 3kW TR03 HW: HWL - low power, HWH - high power TR04 EL: 4kW TR04 HW: HWL - low power, HWH - high power TR06 EL: 6.3 kW TR04 HW: HWL - low power, HWH - high power • Right or left model (The side were the supply air is located when viewed from access side) • Model: TR09, TR12, TR15 • Heating coil: electric = EL, water = HW Available power: TR09 EL: 6kW alt. 15kW TR09 HW: HWL - low power TR12 EL: 9kW alt. 21kW TR12 HW: HWL - low power TR15 EL: 15kW TR15 HW: HWL - low power • Right or left model...
Open the catalog to page 24All Systemair catalogs and technical brochures
-
SYSAQUA_BLUE_H
24 Pages
-
DKIR1
3 Pages
-
MUB 016 200EC
5 Pages
-
KV DUO 150 EC
9 Pages
-
K 100 M sileo
10 Pages
-
SYSPLIT CASSETTE 09 EVO HP Q
4 Pages
-
MRT Catalogue
28 Pages
-
Fan Catalogue 2016
584 Pages
-
Smoke Extract Fans
12 Pages
-
SAVE Brochure
8 Pages
-
Fire Safety products
8 Pages
-
Hydronic Air Conditioning
268 Pages
-
DVu-HP
8 Pages
-
AHU Catalogue
174 Pages
-
Chillers - Air Conditioning
90 Pages
-
Grilles & Diffuser
24 Pages
-
Fan Catalogue
464 Pages
-
Air Conditioning - VRF
68 Pages
-
Fan Catalogue 2012
403 Pages
-
Systemair product news
20 Pages
-
Air Distribution Products
104 Pages
-
Residential Ventilation
64 Pages
-
Air Handling Units Catalogue 2012
138 Pages
-
Air Handling Units
80 Pages
-
Circular Duct Fan prioAir
6 Pages
Archived catalogs
-
Ventilation products 60 Hz
80 Pages
-
Systemair Diffusers
6 Pages
-
Systemair Air Curtains
6 Pages
-
Danvent DV
82 Pages
-
Maxi Air Handling Unit
16 Pages
-
Air handling units
76 Pages
-
Maxi Comfort 800
20 Pages
-
EC/DC Residential units
16 Pages
-
Fans with EC-motors
12 Pages
-
Air curtain
4 Pages
-
Systemair Air curtains
12 Pages
-
TSF exhaust diffuser
4 Pages
-
VR 400/700 DCV/DC Good
12 Pages
-
Systemair residential units
4 Pages
-
KDRE/KDRD
8 Pages
-
TFSK/TFSR roof
6 Pages
-
Axial Fans
40 Pages
-
Systemair circular duct fans
6 Pages