SYSAQUA_BLUE_H
1 / 24Pages

Catalog excerpts

SYSAQUA_BLUE_H - 1

Scroll Compressor SYSAQUA BLUE Air Cooled Water Chillers SYSAQUA BLUE.L (Cooling Only) SYSAQUA BLUE.H (Heat Pump) Model 35B

Open the catalog to page 1
SYSAQUA_BLUE_H - 3

SYSAQUA BLUE ModBus interface available (reading/writing), Unit is optimized for partial load operation, Phase sequence monitor supplied as standard, High SEER and Scop, User-friendly controller that allows to reduce the need of an external water tank in most of comfort air conditioning installations, 2 compressors fitted in tandem for all the range, with an immediate return on investment versus the inverter units, "Night Mode" for energy savings and even more reduced noise level in night operation, Water law is standard for energy savings, Possibility to combine up to 3 units, Refrigerant...

Open the catalog to page 3
SYSAQUA_BLUE_H - 4

SYSAQUA BLUE Specifications General They are available in cooling only (SYSAQUA BLUE.L) and heat pump (SYSAQUA BLUE.H) versions. The condenser is a finned coil constructed with seamless copper tubes mechanically expanded into aluminium fins. The fins of SYSAQUA BLUE.H coils are made of aluminium with hydrophylic blue coating to facilitate water droplets drain. Each unit delivers a nominal cooling capacity of 31.7 kW and a nominal heating capacity of 35.4 kW. The condenser is largely dimensioned in order to optimize performance and defrosting cycles. All units are equipped with two scroll...

Open the catalog to page 4
SYSAQUA_BLUE_H - 5

SYSAQUA BLUE Specifications Control panel Water filter (supplied loose). The units are fitted with an external control panel that displays the operating parameters and alarms. High pressure switch. The control panel is accessible from exterior without removing any parts, nor shutting down the unit, because it is placed on an external panel. Evaporator antifreeze electric heater. The SYSAQUA BLUE.L/SYSAQUA BLUE.H chillers are equipped with a microprocessor based control with a new IHM logic that implements an intelligent control with anticipation of needs, either on entering water...

Open the catalog to page 5
SYSAQUA_BLUE_H - 6

SYSAQUA BLUE Hydraulic circuit Empty : Without pump 1P-SP : Pack Single pump : Cooling only Outdoor coil protection grid Finned coil treatment - epoxy Low water pressure sensor Spring damper rubber pads Water isolation valves Buffer tank : Heat pump Soft Starter Pack nordic Variable pump double speed Variable pump capacity Variable pump constant outlet pressure 4G modem

Open the catalog to page 6
SYSAQUA_BLUE_H - 7

SYSAQUA BLUE Refrigerant Flow Diagram Cooling only version - SYSAQUA BLUE.L CDT Heat pump version - SYSAQUA BLUE.H CDT components M1/M2 Tandem scroll compressors Cycle reversal valve RV1 Outdoor fan motor OF1 Air cooled condenser 3 Filter drier 4 Sight glass 5 Electronic expansion valve 6 Liquid reservoir 7 Plate heat exchanger 8 Pressure tapping point 1/4" 5 safety/control devices FCP High pressure transducer High pressure switch HP CDT Discharge temperature sensor FPE Low pressure transducer Expansion valve pressure tap PS OAT Outdoor air temperature sensor OCT Condenser outlet...

Open the catalog to page 7
SYSAQUA_BLUE_H - 8

SYSAQUA BLUE Hydraulic Circuit Diagram Without pump version Recommended installation - Single pump version Installation Recommended installation Globe valve (option) VA Drain valve VV Connexion flexible CF Water charging valve VR Manometer MN Hydraulic Circuit Filter (supplied loose) FT EWC/LWC VE WPS SS WP PA CL EWT LWT PHE RAG FS VD WT WPT Inlet/Outlet gas male connection 1"1/2 Pressure expansion tank Lack of water pressure switch (optional) Safety valve Pump Automatic air vent Pressure tap 1/4'' Inlet water temperature sensor Outlet water temperature sensor Plate heat exchanger...

Open the catalog to page 8
SYSAQUA_BLUE_H - 9

SYSAQUA BLUE Energy performance Energy class More efficient A++ A+ A B C D E F G Less efficient SYSAQUA BLUE.H Seasonal space heating energy efficiency class according to the Delegated Regulation No. 811/2013 of the European Commission. * According to EN14511-2013 Operating Limits SYSAQUA BLUE.L/SYSAQUA BLUE.H in cooling mode SYSAQUA BLUE.L/SYSAQUA BLUE.H models Water outlet temperature * Eau Water ∆T ** Flow rate ** Air temperature See diagrams on next page * Below 5 °C, glycol is required. ** considered at nominal unit capacity SYSAQUA BLUE.H in heating mode 35B SYSAQUA BLUE.H models...

Open the catalog to page 9
SYSAQUA_BLUE_H - 10

SYSAQUA BLUE Operating Limits SYSAQUA BLUE.L/SYSAQUA BLUE.H in cooling mode 55 50 45 40 35 30 BRINES or WATER + GLYCOL 20 15 10 5 0 BRINES or WATER + GLYCOL + Fan speed controller WATER + Fan speed controller Leaving water temperature (°C) SYSAQUA BLUE.H in heating mode Leaving water temperature (°C)

Open the catalog to page 10
SYSAQUA_BLUE_H - 11

SYSAQUA BLUE Correction Factors Fouling factors - Evaporator Fouling factor (m2.°C/kW) Power input Power input Power input Fouling factors - Condenser Altitude factors Correction factors - Ethylene glycol % glycol Power input Water flow Pressure drop Warning ! Ethylene glycol is toxic to the environment. Moreover, it is not suitable for heating with domestic hot water production by simple exchange. Correction factors - Propylene glycol % glycol Power input Water flow Pressure drop

Open the catalog to page 11
SYSAQUA_BLUE_H - 12

SYSAQUA BLUE Physical Data - SYSAQUA BLUE.L STD SYSAQUA BLUE - Cooling only version Cooling capacity Power input Total EER 100% (1) Energy class EER SEER (2) hsc (2) Energy class SEER Power supply Startup type Maximum operating current Startup current (without Soft Starter) Startup current (with Soft Starter) REFRIGERANT Type Number of refrigerant circuit Charge COMPRESSORS Number Type Part load steps Crankcase heater EVAPORATOR Number Type Water flow Water pressure drop Water volume Antifreeze heater COIL Number Frontal surface Number of rows FAN Number Air flow STD Rotational speed Power...

Open the catalog to page 12
SYSAQUA_BLUE_H - 13

SYSAQUA BLUE Physical Data - SYSAQUA BLUE.H STD SYSAQUA BLUE - Heat pump version Cooling capacity Power input Total EER 100% (1) Energy class EER (2) SEER (2) hsc (2) Energy class SEER Heating capacity Power input Total COP 100% (1) SCOP (2) hsh (2) Energy class SCOP (2) Power supply Startup type Maximum operating current Startup current (without Soft Starter) Startup current (with Soft Starter) REFRIGERANT Type Number of refrigerant circuit Charge COMPRESSORSS Number Type Part load steps Crankcase heater EVAPORATOR Number Type Water flow Cooling mode Water pressure drop Water flow Heating...

Open the catalog to page 13

All Systemair catalogs and technical brochures

  1. DKIR1

    3 Pages

  2. K 100 M sileo

    10 Pages

  3. MRT Catalogue

    28 Pages

  4. DVu-HP

    8 Pages

  5. AHU Catalogue

    174 Pages

  6. Fan Catalogue

    464 Pages

Archived catalogs

  1. Danvent DV

    82 Pages

  2. Air curtain

    4 Pages

  3. Topvex

    60 Pages

  4. KDRE/KDRD

    8 Pages

  5. Axial Fans

    40 Pages