Fans | Air Handling Units | Air Distribution Products | Air Conditioning | Fire Safety | Air Curtains and Heating Products | Tunnel Fans DVU-HP Integrated Reversible Heat Pump System
Open the catalog to page 1DVU-HP Integrated Reversible Heat Pump System The DVU-HP is a complete section with an integrated reversible heat pump for both heating and cooling, and a rotary heat exchanger for effective heat recovery. The section is delivered built into Systemair’s air handling units; Danvent DV and TIME ec, and is pretested from factory ready for operation. The combination of a heat pump and a rotary exchanger ensures a short length and an outstanding operating economy in both heating and cooling situations. The DVU-HP is equipped with two scroll compressors (only one compressor in the two smallest sizes...
Open the catalog to page 2DVU-HP Example: TIME ec 25 with DVU-HP DVU-HP advantages • Fully integrated DX reversible heat pump system for heating and cooling • Integrated rotary heat exchanger • Stepless control of capacity to ensure optimal indoor climate and minimal energy consumption • Very efficient, EER values up to 9,6 • Capacity suits all European climates and can provide cooling to a supply air temperature of +15 °C • Easy to calculate and full technical documentation • Configured and pretested from factory • Low sound level • Compact design • Available in the following sizes: • TIME ec unit, size 10-40,
Open the catalog to page 3Relative humidity [%] Unit size Cooling Capacity Capacity from the cooling circuit kW 70 Outdoor conditions: 34 °C/45% RH. Supply air: 16 °C. Extract air conditions: 23 °C/63% RH. 1 2 3 4 5 6 7 Water vapour content [g/kg] -10 00 Mollier chart for moist air for p = 1 bar Summer S1: Outdoor air S2: After rotary heat exchanger S3: After DVU-HP S4: Extract air S5: After rotary heat exchanger S6: After DVU-HP Winter W1: Outdoor air W2: After rotary heat exchanger W3: After DVU-HP W4: Extract air W5: After rotary heat exchanger 1,00 Total cooling capacity kW
Open the catalog to page 4DVU-HP Cooling and Heating Capacity, DV 40 with DVU-HP Heating capacity Cooling capacity DVU-HP heating circuit Rotary heat exchanger DVU-HP cooling circuit Rotary heat exchanger Outdoor conditions Performance example: DV 40 with 2,5 m3/s. Extract 22 °C/35% RH. Defrosting is not taken into account. Consumed power kW COP, total Performance example: DV 40 with 2,5 m3/s. Extract 23 °C/63% RH.
Open the catalog to page 5* Rotary heat exchanger
Open the catalog to page 6SystemairCAD Design Programme documentation features all relevant consumption levels will be presented. SystemairCAD is the name of technical data and a specification text The most important preconditions are Systemair’s design programme for applicable for the tender documents. set as default, but can easily be adjumodular and compact air handling Everything that must be included in sted to any specific project. When the units. The programme is very userany professional project. The energy air handling unit has been designed, friendly and makes it possible in a consumption levels are visible...
Open the catalog to page 7Systemair A/S Ved Milepælen 7 DK-8361 Hasselager
Open the catalog to page 824 Pages
3 Pages
5 Pages
9 Pages
10 Pages
4 Pages
28 Pages
584 Pages
12 Pages
8 Pages
8 Pages
268 Pages
174 Pages
90 Pages
24 Pages
464 Pages
68 Pages
403 Pages
20 Pages
104 Pages
64 Pages
138 Pages
80 Pages
6 Pages
80 Pages
6 Pages
6 Pages
82 Pages
16 Pages
76 Pages
20 Pages
16 Pages
12 Pages
4 Pages
12 Pages
4 Pages
12 Pages
4 Pages
60 Pages
8 Pages
6 Pages
40 Pages
6 Pages