DVu-HP
1 /8Pages

DVu-HP

DVu-HP
1 /8Pages

Catalog excerpts

DVu-HP-1

Fans | Air Handling Units | Air Distribution Products | Air Conditioning | Fire Safety | Air Curtains and Heating Products | Tunnel Fans DVU-HP Integrated Reversible Heat Pump System

 Open the catalog to page 1
DVu-HP-2

DVU-HP Integrated Reversible Heat Pump System The DVU-HP is a complete section with an integrated reversible heat pump for both heating and cooling, and a rotary heat exchanger for effective heat recovery. The section is delivered built into Systemair’s air handling units; Danvent DV and TIME ec, and is pretested from factory ready for operation. The combination of a heat pump and a rotary exchanger ensures a short length and an outstanding operating economy in both heating and cooling situations. The DVU-HP is equipped with two scroll compressors (only one compressor in the two smallest sizes...

 Open the catalog to page 2
DVu-HP-3

DVU-HP Example: TIME ec 25 with DVU-HP DVU-HP advantages • Fully integrated DX reversible heat pump system for heating and cooling • Integrated rotary heat exchanger • Stepless control of capacity to ensure optimal indoor climate and minimal energy consumption • Very efficient, EER values up to 9,6 • Capacity suits all European climates and can provide cooling to a supply air temperature of +15 °C • Easy to calculate and full technical documentation • Configured and pretested from factory • Low sound level • Compact design • Available in the following sizes: • TIME ec unit, size 10-40,

 Open the catalog to page 3
DVu-HP-4

Relative humidity [%] Unit size Cooling Capacity Capacity from the cooling circuit kW 70 Outdoor conditions: 34 °C/45% RH. Supply air: 16 °C. Extract air conditions: 23 °C/63% RH. 1 2 3 4 5 6 7 Water vapour content [g/kg] -10 00 Mollier chart for moist air for p = 1 bar Summer S1: Outdoor air S2: After rotary heat exchanger S3: After DVU-HP S4: Extract air S5: After rotary heat exchanger S6: After DVU-HP Winter W1: Outdoor air W2: After rotary heat exchanger W3: After DVU-HP W4: Extract air W5: After rotary heat exchanger 1,00 Total cooling capacity kW

 Open the catalog to page 4
DVu-HP-5

DVU-HP Cooling and Heating Capacity, DV 40 with DVU-HP Heating capacity Cooling capacity DVU-HP heating circuit Rotary heat exchanger DVU-HP cooling circuit Rotary heat exchanger Outdoor conditions Performance example: DV 40 with 2,5 m3/s. Extract 22 °C/35% RH. Defrosting is not taken into account. Consumed power kW COP, total Performance example: DV 40 with 2,5 m3/s. Extract 23 °C/63% RH.

 Open the catalog to page 5
DVu-HP-6

* Rotary heat exchanger

 Open the catalog to page 6
DVu-HP-7

SystemairCAD Design Programme documentation features all relevant consumption levels will be presented. SystemairCAD is the name of technical data and a specification text The most important preconditions are Systemair’s design programme for applicable for the tender documents. set as default, but can easily be adjumodular and compact air handling Everything that must be included in sted to any specific project. When the units. The programme is very userany professional project. The energy air handling unit has been designed, friendly and makes it possible in a consumption levels are visible...

 Open the catalog to page 7
DVu-HP-8

Systemair A/S Ved Milepælen 7 DK-8361 Hasselager

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.