Introduction
The document introduces the Danvent DV range of air handling units by Systemair, designed for air volumes between 0.4-24 m3/s. These units are known for their flexibility and innovative construction.

About the Danvent DV
The Danvent DV is a modular air handling unit available in 14 sizes, offering air volume capacities from 0.4-24 m3/s. The casing is designed for thermal and sound insulation, using alu-zinc for corrosion protection.

Product Information
The casing is made of rigid frames with sound and thermal insulated panels, using materials like steel profiles and die-cast aluminum corners. The units operate under pressures of 0-2000 Pa and temperatures from -40/+40 ˚C (standard) to -40/+60 ˚C (special design).

Standards and Certifications
The Danvent DV units comply with CEN and ISO standards, including EN 1886 and EN 13053. They are Eurovent certified and manufactured according to the EU Machinery Directive.

SystemairCAD
SystemairCAD is a design program for calculating and optimizing the energy consumption of air handling units, supporting Eurovent certification and energy classification.

Combination Examples
The document provides examples of commonly applied combinations of the Danvent DV units, highlighting their flexibility.
Specifications and Dimensions
Detailed specifications for various components of the Danvent DV air handling units are provided, including dimensions for single and double height units.

Functions and Components
  • Dampers: Compliant with EN 1751 sealing class 3, featuring aerodynamically formed aluminum blades.
  • Filters: The DVG compact filter and DVF bag filter comply with EN 779 standards.
  • Heat Exchangers: Includes DVC rotary, DVQ plate, and DVR run-around coil heat exchangers.
  • Coils: DVH heating coil and DVK cooling coil are designed for specific applications.
  • Cooling System: The DVU cooler offers stepless capacity control.
  • Fans: The DVE plug fan offers high efficiency and low sound levels.
Standards and Compliance
Emphasizes compliance with standards such as EN 1751 for dampers and EN 779 for filters.

Recommendations and Best Practices
Recommendations include using specific materials for different environments and optimal placement for energy efficiency.

Centrifugal Fan DVV
The DVV centrifugal fan features a double inlet, belt-driven design with backward-curved or forward-curved blades.

Sound Attenuator DVD
The DVD is an absorption sound attenuator designed to reduce noise levels.

Inspection Section DVI
The DVI section is an empty module with an inspection door for servicing.

Empty Section DVO
The DVO is a modular section used to create space between components.

Air Distributor DVL
The DVL ensures even airflow distribution.

Roof Units DV
DV air handling units are available as roof units for outdoor installation.

Control System E28
The E28 control system offers advanced features like heat recovery and variable airflow control.

Dampers (DVA, DVB, DVM, DVP)
Various dampers are available for supply, exhaust, and mixing functions.

Filters (DVG, DVF)
The DVG compact filter and DVF bag filter are designed for easy installation and maintenance.
Filter Specifications:
The F9 filter should be positioned on the positive pressure side of the supply air unit.

Bag Filter DVF Dimensions:
Dimensions vary by size, with single and double height units available.

Rotary Heat Exchanger DVC:
This regenerative heat exchanger offers high efficiency, with variants for different applications.

Drive System:
Available in constant and variable speed options.

Plate Heat Exchanger DVQ:
This recuperative exchanger ensures separation of supply and exhaust air.

Run-around Coil Heat Exchanger DVR:
This system uses a heating coil on the supply airside and a cooling coil on the extract airside.

Heating Coil DVH:
Designed as an air heater, supporting various heating mediums.

Heating Coil Specifications:
Heating coils are constructed with copper or stainless steel tubes and aluminum fins.

Cooling Coil Specifications:
Cooling coils are designed for air cooling using cold water or evaporation.

Cooler DVU Specifications:
The Cooler DVU is a complete cooling system integrated into a DV casing.

Plug Fan DVE Specifications:
The Plug Fan DVE is built into an acoustically insulated air handling unit.
Overview: The document provides detailed technical specifications and descriptions for various models of Danvent DV centrifugal fans and associated components.

Specifications: Lists multiple models of centrifugal fans, such as DVE and DVV series.

Fan Types: Describes BK fans with backward curved blades and FK fans with forward curved blades.

Construction and Features: Fans are constructed with double inlet designs and belt drives.

Additional Components: Details components like the DVL air distributor and DVD sound attenuator.

Dimensions and Installation: Provides detailed dimensions for each fan model and component.

Sound Data: Sound power levels are calculated using SystemairCAD.
Overview: This document provides technical specifications and dimensions for the Danvent DV air handling units.

Specifications:
  • Double Height Units: Models include DV 10-150, DV 10-50, and DV 60-150.
  • Single Height Units: Model DV 10-150.


Dimensions for Ducts:
  • Dimensions are provided for sizes ranging from 10 to 240.


Duct Connection Part DVT:
  • Used for connecting ductwork to the DV air handling unit.


Damper and Fan Configurations:
  • Damper DVA 190-240 and Mixing Damper DVP 190-240 are referenced.


Contact Information:
  • Systemair A/S, Ved Milepælen 7, DK-8361 Hasselager, and Avedøreholmen 50, DK-2650 Hvidovre.
See more

Catalog excerpts

Air Handling Units-1

Fans | Fire and smoke products | Air Handling Units | Air distribution | Accessories | Ventilation systems Air Handling Units Air Handling Units Danvent DV

 Open the catalog to page 1
Air Handling Units-2

Copyright: Systemair A/S 3. edition 2011 We accept no liability for printing errors or alterations of products made after final editing.

 Open the catalog to page 2
Air Handling Units-3

Welcome to Systemair Air Handling Units Introduction We are delighted to present a new edition of our catalogue for air handling units in the range 0,4-24 m3/s (1.500-86.000 m3/h). It is the range Danvent DV, which is marketed under the group’s global trade name Systemair. The air handling unit range Danvent DV has been added many improvements and new developments. The result is an extremely flexible air handling unit, which fulfils our aim to develop products, which are innovative in both construction and function. The Danvent DV range compliments the existing range of air handling units available...

 Open the catalog to page 3
Air Handling Units-4

Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . 3 - 5 About the Danvent DV Product Information Combination Examples Functions . . . . . . . . . . . . . . . . . . . . . . . 14 - 19 Damper DVA . . . . . . . . . . . . . . . . . . 20 - 21 Damper DVB . . . . . . . . . . . . . . . . . . . 22 - 23 Mixing Damper Mixing Damper Compact Filter Rotary Heat Exchanger Plate Heat Exchanger Run-around Coil Heat Exchangers Heating Coil Cooling Coil Sound Attenuator Inspection Section Empty Section Base Frame Dimensions for Ducts Duct Connection Part 4

 Open the catalog to page 4
Air Handling Units-6

About the Danvent DV Casing The casing protect the air handling unit functions, and is very effective for thermal and sound insulation. The casing is built to last. To ensure that the quality of the casing lives up to the high standards of its functions, we use frames and panels which are protected against corrosion using alu-zinc of the highest quality AZ 185. Danvent DV is designed as a modular air handling unit. Each function is placed into an air handling unit casing consisting of one or more modules. The modular functions can be configured for many different applications to make up the heart...

 Open the catalog to page 6
Air Handling Units-7

About the Danvent DV SystemairCAD calculates and optimizes the energy consumption of the air handling unit, and the calculated data are the basis for Eurovent certification and energy classification. SystemairCAD also calculates the Life Cycle Cost (LCC calculation) of the Danvent DV. Disc-Lock An air handling unit consisting of several sections in size 10-150 can be quickly and efficiently assembled using DiscLock, our unique assambly system. The sections can be assembled externally or internally as required. To make it even more user-friendly, the program uses a number of combination examples,...

 Open the catalog to page 7
Air Handling Units-8

Product Information Air Handling Unit Casing Rigid frames with sound and thermal insulated panels. The performance of the air handling unit casing corresponds with the following classifications according to the european standard EN 1886: Materials Frames Closed 1,3/1,5 mm steel profile. Corrosion protection: Alu-zinc AZ 185. Corners Strong die cast aluminium corner pieces. Panels Insulation sandwiched between two 0,8 mm steel sheets. The steel sheets are corrosion protected with alu-zinc AZ 185. Corrosion protection Steel sheets which are protected with alu-zinc AZ 185 ensure a corrosion protection...

 Open the catalog to page 8
Air Handling Units-9

Product Information Standards Eurovent Certification The Danvent DV design is based on the demands in following CEN and ISO standards: Danvent DV air handling units are Eurovent certified. This ensures the conformity between the calculated performance in SystemairCAD design program, and the measured performance at independent test laboratories. EN 305 Heat exchangers. Definition and test procedures. EN 308 Heat exchangers. Test procedures. EN 779 Particulate air filters for general ventilation. EN 1751 Aerodynamic testing of dampers and valves. EN 1886 Air handling units. Mechanical performance....

 Open the catalog to page 9
Air Handling Units-10

Combinations with the DVE plug fan To ease the process of custom-designing a unit, given the enormous range of options, the following are examples of the most commonly applied combinations. Choose the combination that best suit your needs and add or remove functions. Supply air Unit size Rotary Heat Exchanger 10 Rotary Heat Exchanger Single height unit Double height unit Supply air Unit size Plate Heat Exchanger 10 Single height unit Double height unit * DV 10-150 : Height excl. base frame DVZ. DV 190-240 : Height incl. base frame.

 Open the catalog to page 10
Air Handling Units-11

Combinations with the DVE plug fan Extract air Supply air Unit size Run-around Coil Heat Exchangers 10 Single height unit Double height unit Single height unit Double height unit Unit size Single height unit Double height unit Supply air Unit size * DV 10-150 : Height excl. base frame DVZ. DV 190-240 : Height incl. base frame.

 Open the catalog to page 11
Air Handling Units-12

Combinations with DVV centrifugal fan To ease the process of custom-designing a unit, given the enormous range of options, the following are examples of the most commonly applied combinations. Choose the combination that best suit your needs and add or remove functions. Supply air Unit size Rotary Heat Exchanger 10 Single height unit Double height unit Rotary Heat Exchanger Supply air Unit size Plate Heat Exchanger Width Single height unit Double height unit * DV 10-150 : Height excl. base frame DVZ.

 Open the catalog to page 12
Air Handling Units-13

Combinations with DVV centrifugal fan Extract air Supply air Unit size Run-around Coil Heat Exchangers 10 Single height unit Double height unit Single height unit Double height unit Supply air Unit size Supply air Unit size Single height unit Double height unit * DV 10-150 : Height excl. base frame DVZ.

 Open the catalog to page 13
Air Handling Units-14

Dampers The dampers used in Danvent DV comply with EN 1751 sealing class 3. They have contra-rotating aerodynamically formed aluminium blades that ensure a low pressure loss when open. The blades are equipped with special rubber sealing strips between the blades themselves and the frame, to prevent air getting in. For very cold areas, the blades can also be insulated. The dampers ensure a long and trouble-free operation, as the blades are mounted on sturdy square profile shafts and service-free synthetic bearings with large bearing surfaces. A pivoting system placed outside of the airflow and...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.