video corpo

EOLO VIP
20Pages

{{requestButtons}}

Catalog excerpts

EOLO VIP - 1

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER TECHNOLOGY AND INNOVATION AXIAL FANS AND CENTRIFUGAL FANS HEATING COOLING GREEN ENERGY

Open the catalog to page 1
EOLO VIP - 2

VERY IMPORTANT PERFORMANCE The new modulating and condensing suspended gas air heater ADVANTAGES OF EOLO VIP þ 10 YEARS GUARANTEE on the heat exchanger and combustion chamber* þ AUTONOMOUS in its operation þ MODULATION of the thermal from 100% to 30% þ EASY to be installed þ SUITABLE for several types of application þ NOISELESS during its running þ High PERFORMANCE >105% þ Type of gas: Natural gas, LPG Provided with centrifugal fans for the heating of environments with canalization High performance gas air heater. Provided with axial fans for the heating of all types of environment...

Open the catalog to page 2
EOLO VIP - 3

High efficiency for greater energy savings Eolo VIP represents the gas heater with the best cost-benefit ratio. It guarantees high efficiency for greater energy savings and it is suitable for various kind of applications. The version EOLO VIP AE represents the best solution to obtain a high comfort and relevant energy savings. Thermal power modulation EXCELLENT SAVING CONDENSING WITH EFFICIENCY HIGHER THAN HIGH SAVING GOOD SAVING REDUCED THERMAL POWER WITH EFFICIENCY HIGHER THAN MAXIMUM THERMAL POWER EFFICIENCY: HIGH EFFICIENCY Thanks to the use of premix burners matched with new...

Open the catalog to page 3
EOLO VIP - 4

High efficiency for all the types of natural gas and liquid gas used. The premix burner and the electronic boards are positioned into two separated and sealed spaces (IP45 protection), easy to be checked. The premix burner (designed and realized by Systema S.p.A.) is positioned in the lower space and this allows easy and quick maintenance. The new stainless steel combustion chamber, with bundle made of six tubes (where it is possible to install a water trap), is able to guarantee high performance and reduced load losses. The dimensions of the heater have been reduced and it does not take so...

Open the catalog to page 4
EOLO VIP - 5

EOLO BLULINE: The new suspended gas air heater ADVANTAGES OF EOLO BLULINE þ 10 YEARS GUARANTEE on the exchanger and the combustion chamber ** þ AUTONOMOUS in its operation þ EASY to be installed þ SUITABLE for various applications þ NOISELESS during its functioning þ HIGH EFFICIENCY > 93% þ TYPE OF GAS: Natural gas, LPG, OIL þ Also available in the MODULATING version from 70 to 100% of power * EOLO BLULINE: Technical features High efficiency with all the types of natural gas and liquid gas used. The new stainless steel combustion chamber is able to guarantee high efficiency and reduced load...

Open the catalog to page 5
EOLO VIP - 6

"MIX" configuration for external installations of: Condensing EOLO VIP AC and EOLO BLULINE AC All the advantages of EOLO VIP AC and EOLO BLULINE AC for the external installation (MIX version) Technical features of “MIX” version: - Painted steel coating with a self-supporting structure complete of a double roof for a better protection from the atmospheric agents. Centrifugal fans fitted inside the air intake plenum, where it is possible to install a filter and add the duct for the external air intake and air recirculation. Flange on the front side of the equipment to connect the air...

Open the catalog to page 6
EOLO VIP - 7

“EC” EOLO MIX TYPE INTERNAL LEGEND 1. Black steel undergrounded pipe 2. Dielectric connection 3. Manual interception valve (easy to be reached) 4. Zinc-plated gas feeding pipe 5. Support bracket 6. Vibration-damping connection 7. Manual interception valve 8. Outlet pipe of the combustion products 9. Balanced-flow heater (installed externally) 10. Two way firelock 11. Vent 12. External perimeter wall 13. One or three speed centrifugal fan with filter support and airlock regulation 14. Control panel with room thermostat EXTERNAL FUMES “ECRR” EOLO MIX TYPE INTERNAL TIPO “ECRE” EOLO MIX TIPO...

Open the catalog to page 7
EOLO VIP - 8

* Standard conditions

Open the catalog to page 8
EOLO VIP - 9

* For VIP condensing models, it is necessary to install a T element (condensing discharge) at the base of the vertical fume terminal.

Open the catalog to page 9
EOLO VIP - 11

Optionals Control panels see page 63-67 - Fans with speed and uprated head pressure (for AC models) - Filters (for AC models) - Manual/motorized 3 ways air intake duct (AC model) External probe - Separated and coaxial fume and air intake chimneys Separated chimney Coaxial chimneys - Vents, ducts - Air dumper (for AC models) - External probe (to be matched to the specific control panel) - Rotating brackets Standard brackets Rotating brackets

Open the catalog to page 11
EOLO VIP - 12

FUEL OIL HEATER “EOLO” Suspended fuel oil air heater ADVANTAGES OF EOLO BLULINE þ 10 YEARS GUARANTEE on the exchanger and the combustion chamber ** þ AUTONOMOUS in its operation þ EASY to be installed þ SUITABLE for various applications þ NOISELESS during its functioning þ HIGH EFFICIENCY > 90% þ FUEL TYPE: Oil þ AVAILABLE TWO-STAGE VERSION for models EOLO GE/GC 85 and 100 þ ACCESSORIES ARE THE SAME OF EOLO BL (control panels **, chimneys, support brackets, insulation type for external versions, etc.) þ OVERSIZED CAPACITY AND PRESSURE for the version GC (if required) Provided with axial...

Open the catalog to page 12
EOLO VIP - 14

EOLO VIP, EOLO B BC, EOLO B BC RT: Integrated functions The board installed inside the heater represents the electronic brain of the equipment. It has been designed to guarantee a huge range of functions, which can be set using our control panels. These functions can be used profitably when the equipment is combined with Systema control panels. 3 working programs: 1) Manual OFF: keeps just the anti-freeze condition (if enabled) 2) Auto: thermal power according to the set program and timer and also ventilation in the Eolo VIP AE models 3) Manual ON: keeps just the condition set by the...

Open the catalog to page 14
EOLO VIP - 15

Master panel SYS850 and SYS830 for EOLO VIP, EOLO B BC, EOLO B BC RT SYS850 conceived to manage up to 30 air heaters - SYS830 conceived to manage up to 16 air heaters SYS850 and SYS830 are available in 3 versions: þ SYS850 Basic version - Code 05CEQU2715 – Control up to 30 air heaters with 1 thermal zone per each burner, i.e. 30 indipendent thermal zones. þ SYS830 Basic version - Code 00CEQU2674 – Control up to 16 air heaters with n°1 thermal zone per each burner, i.e. 16 independent thermal zones. þ SYS850 LAN - Code 05CEQU2718 þ SYS830 LAN - Code 00CEQU2675 -> Besides the main functions...

Open the catalog to page 15

All SYSTEMA S.P.A. catalogs and technical brochures

  1. SCR-ELE

    8 Pages

  2. OHA 18-36

    8 Pages

  3. OHA URHE

    8 Pages

  4. DS

    1 Pages

  5. SV

    2 Pages

  6. Fresco OK

    4 Pages

  7. KING

    8 Pages

  8. SCR

    8 Pages

  9. EOLO B RT

    12 Pages

  10. EOLO B

    12 Pages

  11. F-LUX

    8 Pages

  12. Fresco

    6 Pages

  13. ANEMOS

    2 Pages

  14. INFRA DES

    8 Pages

  15. OHA

    4 Pages