CCO kit
6Pages

{{requestButtons}}

Catalog excerpts

CCO kit - 1

Compact Change Over - 6-way switch valve with motor QUICK FACTS ○○ Enables heating & cooling in products with only one heat exchanger circuit ○○ Precise flow regulation ○○ For 4-pipe cooling/heating system ○○ Valve, PN10, DN10, ○○ Kvs 0.9 m3/h ○○ Separate kv value settings for cooling/heating ○○ Motor, 24V 2-10V ○○ Enables use of the whole heat exchanger in e.g. a cooling beam for either cooling or heating. ○○ One actuator and one valve, inst

Open the catalog to page 1
CCO kit - 2

Use Switch valve for regulating the heated water - chilled water flow in climate beams and comfort modules. The valve supplies the above product with heated or chilled water which means that the whole product's coil can be utilised and only one actuator with valve is required. Function The valve is regulated by a 2-10V motor which turns the valve 90°. At 2V the valve is in one of its end positions and fully open for cooling. If there is less need for cooling, the volt signal is increased and stops completely at 4.1. In the range between 4.1 and 7.2V the valve is closed. At 7.2V the valve...

Open the catalog to page 2
CCO kit - 3

Technical / mechanical design Characteristics & advantages The flow sound from the valve is very low, lower than for traditional valves of the same dimension. The design means that heating and cooling can never be run simultaneously, but both circuits will be in contact with one another which means that a very minute volume of heated water and chilled water will be exchanged when the valve switches between heating and cooling. The exchanger’s water volume being exchanged is approx. 1 litre, and the changeover between cooling and heating operation will normally occur only once per 24-hour...

Open the catalog to page 3
CCO kit - 4

Dimensions, valve Pressure class Maintenance The valve and motor do not require any maintenance at all. Swegon reserves the right to alter specifications. 20170313

Open the catalog to page 4
CCO kit - 5

Dimensions and weight, motor Electrical data Figure 7. Dimensions, motor, viewed from side. 2. Turn valve shaft to end position (2) full cooling and bleed the system. 3. Turn valve shaft to end position (3) full heating and bleed the system. 4. Startup is done with motor anywhere between end positions 20170313 Swegon reserves the right to alter specifications.

Open the catalog to page 5
CCO kit - 6

Dimensions, valve with mounted motor 210 Figure 8. Dimensions, valve with motor, viewed from side. Figure 9. Dimensions, valve with motor, viewed from above. Swegon reserves the right to alter specifications.

Open the catalog to page 6

All SWEGON catalogs and technical brochures

  1. Kappa Rev

    6 Pages

  2. Omega Sky

    12 Pages

  3. KITE CEILING

    4 Pages

  4. CONDUCTOR

    13 Pages

  5. ACTUATOR

    2 Pages

  6. REACT

    12 Pages

  7. PARASOL

    1 Pages

  8. ALD

    6 Pages

  9. WCD2 PARASOL

    6 Pages

  10. Swegon CASA®

    16 Pages

  11. GOLD & COMPACT

    24 Pages

  12. Air Diffusers

    20 Pages

  13. MIRUVENT

    32 Pages

  14. LPMA

    2 Pages

  15. Swegon SILVER

    20 Pages

Archived catalogs

  1. Biscay

    4 Pages

  2. Air diffusers

    20 Pages

  3. COMPACT

    4 Pages

  4. PARASOL

    16 Pages