Catalog excerpts
Compact Change Over - 6-way switch valve with motor QUICK FACTS ○○ Enables heating & cooling in products with only one heat exchanger circuit ○○ Precise flow regulation ○○ For 4-pipe cooling/heating system ○○ Valve, PN10, DN10, ○○ Kvs 0.9 m3/h ○○ Separate kv value settings for cooling/heating ○○ Motor, 24V 2-10V ○○ Enables use of the whole heat exchanger in e.g. a cooling beam for either cooling or heating. ○○ One actuator and one valve, inst
Open the catalog to page 1Use Switch valve for regulating the heated water - chilled water flow in climate beams and comfort modules. The valve supplies the above product with heated or chilled water which means that the whole product's coil can be utilised and only one actuator with valve is required. Function The valve is regulated by a 2-10V motor which turns the valve 90°. At 2V the valve is in one of its end positions and fully open for cooling. If there is less need for cooling, the volt signal is increased and stops completely at 4.1. In the range between 4.1 and 7.2V the valve is closed. At 7.2V the valve...
Open the catalog to page 2Technical / mechanical design Characteristics & advantages The flow sound from the valve is very low, lower than for traditional valves of the same dimension. The design means that heating and cooling can never be run simultaneously, but both circuits will be in contact with one another which means that a very minute volume of heated water and chilled water will be exchanged when the valve switches between heating and cooling. The exchanger’s water volume being exchanged is approx. 1 litre, and the changeover between cooling and heating operation will normally occur only once per 24-hour...
Open the catalog to page 3Dimensions, valve Pressure class Maintenance The valve and motor do not require any maintenance at all. Swegon reserves the right to alter specifications. 20170313
Open the catalog to page 4Dimensions and weight, motor Electrical data Figure 7. Dimensions, motor, viewed from side. 2. Turn valve shaft to end position (2) full cooling and bleed the system. 3. Turn valve shaft to end position (3) full heating and bleed the system. 4. Startup is done with motor anywhere between end positions 20170313 Swegon reserves the right to alter specifications.
Open the catalog to page 5Dimensions, valve with mounted motor 210 Figure 8. Dimensions, valve with motor, viewed from side. Figure 9. Dimensions, valve with motor, viewed from above. Swegon reserves the right to alter specifications.
Open the catalog to page 6All SWEGON catalogs and technical brochures
-
Coolblade In Rack
6 Pages
-
Kappa Rev
6 Pages
-
Kappa Rev LGW
6 Pages
-
Omega Sky
12 Pages
-
KITE CEILING
4 Pages
-
CONDUCTOR
13 Pages
-
CG IV / CG IV-kit
2 Pages
-
ACTUATOR
2 Pages
-
REACT
12 Pages
-
PARASOL
1 Pages
-
ALD
6 Pages
-
Waterborne climate systems
16 Pages
-
WCD2 PARASOL
6 Pages
-
Swegon CASA®
16 Pages
-
GOLD & COMPACT
24 Pages
-
Demand-controlled Ventilation
16 Pages
-
Air Diffusers
20 Pages
-
Chillers and Heat Pumps
44 Pages
-
MIRUVENT
32 Pages
-
LPMA
2 Pages
-
Home Ventilation
16 Pages
-
Swegon SILVER
20 Pages
Archived catalogs
-
Biscay
4 Pages
-
Baltic, active chilled beams
4 Pages
-
COMPACT, Product overview
12 Pages
-
GOLD, Product overview
20 Pages
-
Water-based Climate Systems
12 Pages
-
Air diffusers
20 Pages
-
COMPACT
4 Pages
-
PARASOL
16 Pages
-
GOLD - air handling units
20 Pages