Catalog excerpts
EN 81-20 & EN 81-50 Main SODIMAS requirements and solutions
Open the catalog to page 1Opening the car doors Door detection Fire resistance Strength of the walls Strength of the doors Light intensity in the car Evacuation of users Self-checking of brakes Certification of the machines Strength of the shaft walls
Open the catalog to page 2uSQDIMAS ITS Safety refuge Height and strength of balustrades Safety on the car roof Mechanical safety in the shaft Electrical safety in the shaft Emergency lighting in the shaft Pit bottom access Safety component markings Information for technicians Use of service lifts Door shunt
Open the catalog to page 3User safety
Open the catalog to page 4Opening the car doors Outside the locking area, the opening of the car doors is limited to 50 mm under an applied force of 1000 N. Two solutions are offered depending on the type of door: Mechanical door locking. Opening limiter mechanism. User safet
Open the catalog to page 5Door detection Two SODIMAS solutions are possible in the event of failure of the detection system (>50 mm): The door closing speed is reduced and an audible signal notifies users of a fault. User safet
Open the catalog to page 7User safety
Open the catalog to page 8Fire resistance The materials chosen for the car floor, walls, ceiling and aesthetics meet the following minimum requirements: Floor: Cfl s2 (French Classification M3) Wall: C s2 d1 (French Classification M2) Ceiling: C s2 d0 (French Classification M2)
Open the catalog to page 9User safety
Open the catalog to page 10Strength of the walls Under an applied force of 1000 N, all types of car walls shall withstand: Articles: 5.4.3.2.2.b Without permanent deformation > 1 mm. Car walls fully or partially made of laminated glass shall withstand shocks by: Articles: 5.4.3.2.3 Rigid pendulum (10 kg) with a drop height of 500 mm. Soft pendulum (45 kg) with a drop height of 700 mm.
Open the catalog to page 11User safety
Open the catalog to page 12► The devices providing mechanical linkage between panels shall withstand to the force of 1000 N. Article: 5.3.11.3 Under an applied force of 300 N all types of doors shall withstand: ► Without permanent deformation > 1 mm. ► Without elastic deformation > 15 mm. Article: 5.3.5.3.1 a Under an applied force of 1000 N, all types of doors shall withstand: ► Without permanent deformation > 10 mm. Article: 5.3.5.3.1 b In case of shock: ► A mechanical device prevents the door panels from disengaging from their guides. / 2
Open the catalog to page 13User safety
Open the catalog to page 14Light intensity in the car The minimum light intensity is as follows: 100 lux in normal mode at 1 m above the floor. 5 lux in emergency mode for 1 hour at 1 m at the centre of the car and near the emergency push buttons. User safet
Open the catalog to page 15User safety
Open the catalog to page 16Evacuation of users In cases where installation of a safety hatch on the roof of the car is required, its dimensions are as follows: Minimum clear opening 0.40 m x 050 m. Under an applied force of 300 N the toe guard shall withstand: Without permanent deformation > 1 mm. Without elastic deformation > 35 mm.
Open the catalog to page 17User safety
Open the catalog to page 18Self-checking of brakes The QItouch performs the self-checking of the brakes: Each brake can be individually tested from the QItouch box on the landing. Certificates for SODIMAS equipment always includes self-checking of brakes. User safet
Open the catalog to page 19User safety
Open the catalog to page 20Certification of the machines The upward overspeed protection system of the car can act on the same shaft as the traction pulley provided that the shaft is only supported statically on 2 points: ▸ All SODIMAS machines have an APAVE compliance certificate. User safety
Open the catalog to page 21User safety
Open the catalog to page 22Strength of the shaft walls Under an applied force of 1000 N, the shaft walls shall withstand: Without permanent deformation > 1 mm. Without elastic deformation > 15 mm. Without permanent deformation in the case of laminated glass type walls.
Open the catalog to page 23The minimum possible safety refuge are as follows: At the top of the shaft and in the pit:
Open the catalog to page 25Height and strength of the balustrades The height of the balustrades depends on the free space between the car and the shaft walls: ► If the free horizontal distance between the inner edge of the balustrade handrail and the shaft wall is: > 0.30 m and < 0.50 m, the height of the balustrades is 0.70 m > 0.50 m, the height of the balustrades is 1.10 m The balustrades shall withstand an applied force of 1000 N without elastic deformation > 50 mm.
Open the catalog to page 27► An inspection control device can be operated from a safety refuge. ► The working surface is anti-slip ► A protection of the safety chain by means of a residual current protected device is installed. ► The roof shall withstand an applied force of 2000 N over an area of 0.30 m by 0.30 m without any permanent deformation.
Open the catalog to page 29► The cable ends are secured by self tightening wedge type sockets, ferrule secured eyes or swage terminals. Article: 5.5.2.3.1 ► Devices to prevent the cables from coming out of the pulley grooves are located in sufficient numbers depending on their configurations. Article: 5.5.7 ► The car stops mechanically in the event of an uncontrolled or unexpected car movement resulting from maintenance or inspection. The safety-gear device is operated by a clamp that locks the cable of the speed governor. Normal operation can be resumed after operating the QItouch. Article: 5.2.6.4.4.1
Open the catalog to page 31Interrupteur differenciel m
Open the catalog to page 32Electrical safety in the shaft ► Two means of a residual current protected device are installed in the shaft: Article: 5.10.1.2.3: - the safety chain - the car door operator(s) ► The QItouch ensures that the car speed does not exceed 0.30 m/s in the inspection operation when it is located at least 2 m from the top and bottom of the shaft. Article: 5.12.1.5.2.1 ► Lighting of 200 lux is provided for the QItouch controler. Article: 5.2.1.4.2
Open the catalog to page 33Emergency lighting in the shaft The emergency light intensity must be 5 lux for 1 hour. It must be located at 1 m from the centre of the car near the emergency button. ► Using the QItouch SODIMAS controls the emergency lighting throughout the shaft in the event of a power power failure.
Open the catalog to page 35A patented portable inspection box accessible from the landing includes: ► A lighting control. ► An inspection control device that can be operated from around the safety refuge. ► A power socket. Two types of ladder are provided to access the pit to a depth of less than 2.5 m: ► A fixed ladder as defined in Annex F. ► or a retractable ladder with a spring as defined in Annex F or equivalent. The landing door unlocking system is accessible from the bottom of the pit or from the ladder. The counterweight screen shall withstand a force of 300 N without touching the counterweight.
Open the catalog to page 37All SODIMAS catalogs and technical brochures
-
Range
28 Pages
-
SODI@COM
4 Pages
-
Controller NG240
2 Pages
-
Multiplexing QuickInstall
8 Pages
-
QItouch
4 Pages
-
REMOTE LIFT ALARM
12 Pages
-
TA140
2 Pages
-
TA125
2 Pages
-
Sodiview
4 Pages
-
SoLIMAX
6 Pages
-
Linear tension device
2 Pages
-
Gearless
12 Pages
-
PMD 280
2 Pages
-
cabines teintes
12 Pages
-
cabine skinplate
2 Pages
-
EOL
14 Pages
-
My Lift
24 Pages
-
Univers cars
28 Pages
-
Cabines Vitrées
16 Pages
-
Série 40 cars
16 Pages
-
Car Square
12 Pages
-
Bluestyle
16 Pages
-
Lift with machine room
12 Pages
-
Lift Médium
46 Pages
Archived catalogs
-
Options
2 Pages
-
Série 40 Moka
16 Pages
-
All cars Download Collection
32 Pages
-
Teintes cabines
8 Pages
-
Lineha cars
28 Pages
-
Range VM VMBe
36 Pages
-
Gamme VSpace
44 Pages
-
Book
40 Pages
-
SMALL 225/300/450 kg
14 Pages
-
SODIMAS ascenseurs
72 Pages
-
VM Speed 400/450/630/1000kg
8 Pages
-
SQUARE
8 Pages
-
ODEON
10 Pages
-
LIFT WITH MACHINE ROOM
12 Pages
-
MEDIUM IMPLANTS
4 Pages
-
MEDIUM
14 Pages
-
VMOTIONBE IMPLANTS
4 Pages
-
VMOTIONBE
14 Pages
-
SMALL IMPLANTS
21 Pages
-
SMALL
12 Pages