Rubbol WP 194
2Pages

{{requestButtons}}

Catalog excerpts

Rubbol WP 194 - 1

water thinnable store and transport store in a cool place cleaning of in a frost free area equipment with limited dimensi stable wooden WOOD COATINGS Product description Binder type Application temperature Drying times Waterthinnable.white base and midcoat for constructions made of pine and leaf wood with isolating properties against waterthinnable extracts, exterior and interior. A dry film thickness of 30um can be achieved if flow coated twice. - good run-off properties - wood moisture regulating - good pore wetting - high filling properties Acrylic -Alkyd resin combination Titanium dioxid dipping, flow-coating Working viscosity is approx. 13 seconds in a DIN cup 4 mm i.e. approx. 38 - 44 seconds in a ISO cup 3 mm at 20° C material temperature. 50 - 160 ml/m2, depending on application method, type and absorption properties of wood (exact values must be established through a sample) Ajust with approx. 15-20% water to working viscosity 15 - 25 °C for substrate, air and material at approx. 60 % R.H. Dust dry: after approx. 30 minutes Sandable: after approx. 4 hours Recoatable: after approx. 4 - 6 hours waterborne The drying process of the coating depends on the applied wet film thickness and can extend when using timber with a high extract contents or drying in damp/cold conditions. During the drying process one should ensure for adequate If the drying conditions are not upheld, damages within the coating cannot be warranted. Clean directly after use with water, if needed with washing up liquid or with ST 830. A dipping tank containing material must be covered correctly and stirred or circulated regulary. The minimum storage stability of sealed containers is 2 years. After ending of the storage time the product still can be usable, but some attributes may vary from new product. Therefore such over-stored product has to be applied with special attention. Opened cans must be sealed correctly! Store in a cool but frost-protected area. Only residue emptied cans can be disposed via recycling. Liquid wastes must be disposed of according to national regulations or according to EU-disposal key 08 01 12. In accordance with EC guide lines - Material safety data sheet, point 15. The substance is not be employed near water courses. They are only to be used according to the instructions and in the permitted areas. Misuse can lead to health and environmental damages. Dipping tanks or reservoirs: when using metal reservoirs, we recommend using None rusting steel i.e. V2A, the use of other materials can lead to corrosion. Before use, read the identification and product information. Even when working with low emission products one should take care of the customary protection measures. The wood moisture content for the application of Sikkens coating systems should be between 12 % and 15 %. According to the guidelines for window coating systems, published by the Federal German Committee for Paint and Material Value Protection (Instruction Leaflet No. 18), of VOB, Parte, DIN 18363, and the recommendations of the German Institute for Window Technology e.V. in Rosenheim, all wooden constructions in buildings must be coated on all sides with at least one primer and one intermediate coat (minimum dry film thickness 30 urn) before they are incorporated in buildings. The choice and use of the coating system, especially the colour shade, should also be taken into account. Darker shades can increase the surface temperature (up to 80 C). For use in a technical industrial companies and exclusively released for Sikkens systems recomondations. To ensure a correct adhesion of the following coating system, the paint system should not be sanded down to the With some wood species, especially hardwoods, discolouration can appear due to natural wood extractives. The sealing process with Kodrin WV 470/472 should only be applied after the mid coat VOC guideline EU limit value for this product (Kat. A/d): 150 g/l (2007)/130 g/l (2010). This product contains max. 30 g/l VOC. Relevant information The here mentioned coating system is only an example, other systems are possible. All external materials (i.e. fillers, tapes, sealing compounds, cleaners) must be checked for compatibility with the coating Please observe the relevant Technical Data Sheets or seek advice from the Sikkens sales representative or contact the technical centre. Hazard identification General instructions Akzo Nobel Industrial Coatings Ltd Unit 4a, Mercer Way, Shadsworth Blackburn, Lanes, BB12QZ Akzo Nobel Industrial Coatings Ltd Unit 4a, Mercer Way, Shadsworth Blackburn, Lanes, BB12QZ Akzo Nobel Wood Coatings GmbH Dijsseldorfer StraGe 96-100 D-40721 Hilden

Open the catalog to page 1
Rubbol WP 194 - 2

WOOD COATINGS Foam formation during the application can be reduced by using defoamer WV 888. For information concerning the dosage, please see the relevant Technical Data Sheet. System structure: Dimensional and semi dimensional stable wooden constructions All details on our products contained in this publication do not represent details of the quality of the goods. The quality, suitability, qualification and function intended use of our goods shall be determined exclusively in accordance with the product descriptions based on the respective sales agreements. In each case, deviations...

Open the catalog to page 2

All SIKKENS catalogs and technical brochures

  1. Cetol WP 575

    1 Pages

  2. Cetol WM 675

    2 Pages

  3. Cetol WF 945

    2 Pages