Cetol WP 567 BPD
2Pages

{{requestButtons}}

Catalog excerpts

Cetol WP 567 BPD - 1

WOOD COATINGS water thinnable equipment with limited dimensi stable wooden Wear protective Product description Uptake consumption Binder type Application temperature Drying times Hazard identification General instructions Waterborne, translucent, impregnating base stain (fluid timber protecting agent) for the protection against blue stain fungi and rot of none statically subjected wooden constructions without earth contact, exterior. - deep penetration - colour outline The active substances are notified acc. guideline 98/8/EG and correspond to the specification EN 599 against blue stain Wood protection agents must be registered according to the BPD. (BPD = Biocide Product Directive) The examination follows the uptake value: 120-160 ml/m2 i.e. 123-164 g/m2 for timber in the resistance classes 3-5 With the choice of the different translucent colours, one should observe the Rosenheimer paint classification table. All translucent colours can be mixed with each other. The optical appearence of different systems can differ depending on substrate and wet film thicknesses, for this reason one should make trials before application. Dark translucent colours give better weather durability than light colours. Colourless systems are not suitable for Timbers which contain extractives i.e. Oak, Larch or tropical woods can cause discolouring - these can appear after Translucent, colour tints i.e. from the Joinery Colour Collection. Acrylic Copolymer Light genuine, weather resistant translucent pigments Dipping, flow coat Working viscosity is approx. 11 seconds in a DIN cup 4 mm i.e. approx. 23 - 25 seconds in a ISO cup 3 mm at 20° C material temperature. Brushing machine, vacuum coater 50 - 160 ml/m2, depending on application method, type and absorption properties of wood (exact values must be established through a sample) 15 - 25 °C for substrate, air and material at approx. 60 % R.H. Dust-dry: after approx. 30 minutes Recoatable: after approx. 4 - 6 hours waterborne Clean directly after use with water, if needed with washing up liquid or with ST 830. A dipping tank containing material must be covered correctly and stirred or circulated regulary. The minimum storage stability of sealed containers is 2 years. After ending of the storage time the product still can be usable, but some attributes may vary from new product. Therefore such over-stored product has to be applied with special attention. Opened cans must be sealed correctly! Store in a cool but frost-protected area. Only residue emptied cans can be disposed via recycling. Liquid wastes must be disposed of according to national regulations or according to EU-disposal key 03 02 02. In accordance with EC guide lines - Material safety data sheet, point 15. The Impregnation serves as a protection of none statically subjected wooden constructions without earth contact, exterior, against blue stain and rot according to DIN 68800, part 3. Not for use with wood which has got direct contact with food or food preparation. Only for the use of qualified Dipping tanks or reservoirs: when using metal reservoirs, we recommend using None rusting steel i.e. V2A, the use of other materials can lead to corrosion. Biocide products must be handled carefully Before use, read the identification and product information. Even when working with low emission products one should take care of the customary protection measures. Not to be used near waterways. The fluid must not entre water. Wood preservatives contain biozid substances for the protection against pest control. They are only to be used according to instructions and in permitted working areas. Misuse can lead to a hazard to health. The wood moisture content for the application of Sikkens coating systems should be between 12 % and 15 %. According to the guidelines for window coating systems, published by the Federal German Committee for Paint and Material Value Protection (Instruction Leaflet No. 18), of VOB, Parte, DIN 18363, and the recommendations of the German Institute for Window Technology e.V. in Rosenheim, all wooden constructions in buildings must be coated on all sides with at least one primer and one intermediate coat (minimum dry film thickness 30 urn) before they are incorporated in buildings. The choice and use of the coating system, especially the colour shade, should also be taken into account. Darker shades can increase the surface temperature (up to 80 C). For use in a technical industrial companies and exclusively released for Sikkens systems recomondations. Akzo Nobel Industrial Coatings Ltd Unit 4a, Mercer Way, Shadsworth Blackburn, Lanes, BB12QZ United Kingdom Akzo Nobel Industrial Coatings Ltd Unit 4a, Mercer Way, Shadsworth Blackburn, Lanes, BB12QZ Rep of Ireland Akzo Nobel Wood Coatings GmbH Diisseldorfer StraBe 96-100 40721 Hilden Germany

Open the catalog to page 1
Cetol WP 567 BPD - 2

WOOD COATINGS To ensure a correct adhesion of the following coating system, the paint system should not be sanded down to the VOC guideline EU limit value for this product (Kat. A/f): 150 g/l (2007)/130 g/l (2010). This product contains max. 80 g/l VOC. Relevant information The the denibbing process may only be made after the following coating system. The here mentioned coating system is only an example, other systems are possible. All external materials (i.e. fillers, tapes, sealing compounds, cleaners) must be checked for compatibility with the coatinc Please observe the relevant...

Open the catalog to page 2

All SIKKENS catalogs and technical brochures

  1. Cetol WP 575

    1 Pages

  2. Cetol WM 675

    2 Pages

  3. Cetol WF 945

    2 Pages