1. Catalogs
  2. SIKKENS
  3. Cetol WF 945

Cetol WF 945

Cetol WF 945

Cetol WF 945

Product catalog summary
Product Description: Cetol WF 945 is a waterborne, transparent, matt mid and finish coat designed for both exterior and interior wooden constructions. It offers good weather resistance and is safe according to DIN EN 71, part 3 standards. The product is available in various translucent colors, which can be mixed, but trials are recommended before application due to potential differences in appearance based on substrate and film thickness.
Specifications: The product is packaged in 5 L and 20 L containers and is applied via spraying. Recommended wet film thickness is 2 x 150µm or 1 x 150 to max. 300µm. It is advised to apply in two coats for better durability. The product can be thinned with water up to 5% if necessary.
Application Conditions: The ideal application temperature is between 15 - 25 °C with a relative humidity of approximately 60%. Drying times at 23 °C and 50% R.H. are approximately 30 minutes to dust dry, 4 hours to sandable, and 4-6 hours to recoatable. Adequate temperature and ventilation are crucial during the drying process.
Storage and Disposal: The product should be stored in a cool, frost-free area with temperatures between +5 - +30 °C. Sealed containers have a minimum storage stability of 2 years. Disposal should follow national regulations, and only residue-empty cans can be recycled.
Safety and Handling: Users should read the product information and adhere to customary protection measures. The wood moisture content should be between 12% and 15% for application. All wooden constructions must be coated on all sides with at least one primer and one intermediate coat before installation.
Additional Recommendations: Darker shades are recommended for better weather durability. Light shades on timber with high extract contents may cause discoloration. A pore-filling midcoat is recommended for leaf woods.
Contact Information: Akzo Nobel Industrial Coatings Ltd and Akzo Nobel Wood Coatings GmbH provide contact details for further inquiries.
See more

Catalog excerpts

Cetol WF 945-1

WOOD COATINGS limited dimensi stable wooden store in a cool place cleaning of equipment with Product description Gloss level Binder type Application temperature Drying times Waterborne, transparent, matt mid and finish coat for wooden constructions exterior and interior. - good weather resistance - sweat and saliva genuine (according to DIN EN 71,part 3) - clear, high wear layer With the choice of the different translucent colours, one should observe the Rosenheimer paint classification table. All translucent colours can be mixed with each other. The optical appearence of different systems can differ depending on substrate and wet film thicknesses, for this reason one should make trials before application. Dark translucent colours give better weather durability than light colours. Colourless systems are not suitable for Timbers which contain extractives i.e. Oak, Larch or tropical woods can cause discolouring - these can appear after Translucent, colour tints i.e. from the Joinery Colour Collection. pure acrylic dispersion It is recommeded to apply translucent colours in two coats. 150 - 300 ml/m2, depending on applied wet film thickness per coat without losses. If necessary with water max. 5 %. 15 - 25 °C for substrate, air and material at approx. 60 % R.H. Dust dry: after approx. 30 minutes Sandable: after approx. 4 hours Recoatable: after approx. 4 - 6 hours waterborne The drying process of the coating depends on the applied wet film thickness and can extend when using timber with a high extract contents or drying in damp/cold conditions. During the drying process one should ensure for adequate If the drying conditions are not upheld, damages within the coating cannot be warranted. Clean directly after use with water, if needed with washing up liquid or with ST 830. The minimum storage stability of sealed containers is 2 years. After ending of the storage time the product still can be usable, but some attributes may vary from new product. Therefore such over-stored product has to be applied with special attention. Opened cans must be sealed correctly! Store in a cool but frost-protected area. Only residue emptied cans can be disposed via recycling. Liquid wastes must be disposed of according to national regulations or according to EU-disposal key 08 01 12. In accordance with EC guide lines - Material safety data sheet, point 15. Before use, read the identification and product information. Even when working with low emission products one should take care of the customary protection measures. The wood moisture content for the application of Sikkens coating systems should be between 12 % and 15 %. According to the guidelines for window coating systems, published by the Federal German Committee for Paint and Material Value Protection (Instruction Leaflet No. 18), of VOB, Parte, DIN 18363, and the recommendations of the German Institute for Window Technology e.V. in Rosenheim, all wooden constructions in buildings must be coated on all sides with at least one primer and one intermediate coat (minimum dry film thickness 30 urn) before they are incorporated in buildings. The choice and use of the coating system, especially the colour shade, should also be taken into account. Darker shades can increase the surface temperature (up to 80 C). For use in a technical industrial companies and exclusively released for Sikkens systems recomondations. VOC guideline EU limit value for this product (cat. A/d): 130 g/l (2010) This product contains max. 36 g/l VOC. Relevant information The here mentioned coating system is only an example, other systems are possible. All external materials (i.e. fillers, tapes, sealing compounds, cleaners) must be checked for compatibility with the coating Please observe the relevant Technical Data Sheets or seek advice from the Sikkens sales representative or contact the technical centre. Coating recommendation When using the light shades on timber with high extract contents (i.e. Meranti, Larch, Oak) discolouration due to When coating leaf woods, we recommend the use of a pore filling midcoat. Hazard identification Akzo Nobel Industrial Coatings Ltd Unit 4a, Mercer Way, Shadsworth Blackburn, Lanes, BB12QZ Akzo Nobel Industrial Coatings Ltd Unit 4a, Mercer Way, Shadsworth Blackburn, Lanes, BB12QZ Akzo Nobel Wood Coatings GmbH Dijsseldorfer StraGe 96-100 40721 Hilden

 Open the catalog to page 1
Cetol WF 945-2

WOOD COATINGS System structure: Dimensional stable wooden constructions All details on our products contained in this publication do not represent details of the quality of the goods. The quality, suitability, qualification and function intended use of our goods shall be determined exclusively in accordance with the product descriptions based on the respective sales agreements. In each case, deviations typical of the sector shall be admissible, unless agreed in writing otherwise. All details correspond to todays state of technology. We make no claim as to the completness of the stated coating...

 Open the catalog to page 2

All SIKKENS catalogs and technical brochures

  1. Rubbol WF 361

    2  Pages

  2. Rubbol WF 373

    2  Pages

  3. Rubbol WF 375

    2  Pages

  4. Rubbol WF 378

    2  Pages

  5. Rubbol WF 380

    2  Pages

  6. Cetol WP 575

    1  Page

  7. Rubbol WP 151

    2  Pages

  8. Rubbol SP 110

    2  Pages

  9. Rubbol WP 105

    2  Pages

  10. Cetol WM 675

    2  Pages

  11. Rubbol WP 194

    2  Pages

  12. Rubbol WP 193

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.