RRV934

Product catalog summary
Overview
The Siemens Synco™ living Multi-controller RRV934 is a versatile RF-based device designed for controlling up to two room groups and ventilation plants with up to three stages. It operates on the KNX standard at 868 MHz and is powered by AC 230 V. The controller includes three universal relay outputs, an additional output for a 3-position actuator or as a fourth relay output, four universal inputs, and two universal outputs (DC 0…10 V).
Specifications
- RF communication: KNX standard (868 MHz, bidirectional)
- Power: AC 230 V, 50 Hz, max. 7 VA
- Relay outputs: 3 universal, 1 additional
- Inputs: 4 universal
- Outputs: 2 universal (DC 0…10 V)
- Operating voltage: AC 230 V (± 10%)
- Frequency: 50 Hz
- Protocol: KNX RF-compatible
Applications
The RRV934 is designed for integration into the Siemens Synco living system, suitable for heating plants and ventilation control. It supports precontrol of two room groups and is compatible with various actuators for heating circuits. It also manages 3-stage ventilation plants influenced by humidity, indoor air quality, or CO2 levels.
Functions
- Universal relay outputs for controlling equipment like 3-stage ventilation units.
- Universal inputs for signals from sensors for room group precontrol or ventilation plant control.
- Converts percentage-scaled signals to analog DC 0…10 V signals.
- Special functions include flow temperature control, return temperature limitation, and cooling mode.
- Ventilation functions include stage selection, humidity sensor monitoring, and CO2/VOC sensor for indoor air quality control.
Device and System Functions
- Binding process for integration into the RF system.
- State query and RF binding test via multifunction button.
- Manual operation and reset to supply state capabilities.
- RF and mains failure handling.
Installation and Maintenance
The RRV934 can be mounted on top hat rails or with fixing screws. It requires proper connection of inputs and outputs before power application. The device is maintenance-free and must be disposed of according to electronic scrap regulations.
Warranty
Technical data is warranted only when used with the Siemens Synco living system. Compatibility with third-party devices is not guaranteed by Siemens.
Conformity and Standards
The Siemens Multi-controller RRV934 complies with several directives and standards, ensuring its safety and functionality. It adheres to the EMC directive for immunity and emissions, the Low-voltage directive for electrical safety, and the RTTE directive for wireless communication. Specific standards include EN 60730-1, EN 60730-2-9 for both EMC and Low-voltage directives, and EN 300220-2, EN 301489-1, EN 301489-3 for the RTTE directive. The device is classified as Safety Class II according to EN 60730 and has a housing protection rating of IP30 as per EN 60529.
Environmental and Quality Standards
The product is designed with environmental compatibility in mind, following the Environmental Product Declaration CE1E2709en, which covers RoHS compliance, substance composition, packaging, and disposal. It also complies with ISO 14001 for environmental management and ISO 9001 for quality management, alongside SN 36350 for environmentally compatible products.
Technical Specifications
The controller operates under various climatic conditions, with specific temperature and humidity ranges for operation, transport, and storage. It supports a range of electrical connections, including universal inputs and outputs, and potential-free relay outputs for AC 24-230 V. The device is designed for use at elevations up to 3000 meters above sea level.
Physical Characteristics
The housing is made from PC+ABS plastics, with upper and lower sections colored RAL 7035 light-gray and RAL 5014 dove-blue. The unit, complete with accessories, weighs 0.602 kg.
Operational Features
The controller features universal inputs and outputs, which can be configured for various functions such as temperature measurement or digital input. It includes multiple relay outputs that can be used for mains or low-voltage applications. The configuration of these inputs and outputs is flexible, allowing for customization based on specific application needs.
Application Examples
Examples provided include controlled ventilation of apartments using step selectors and HR bypass configurations, demonstrating the versatility of the controller in different settings.
See more

Catalog excerpts

RRV934-1

SIEMENS Synco™ living • RF-based multi-controller - For precontrol of up to 2 room groups - For control of ventilation plant with up to 3 stages • RF communication based on KNX standard (868 MHz, bidirectional) • Mains-powered AC 230 V • 3 universal relay outputs • 1 additional output - for 3-position actuator, or - as a 4th universal relay output • 4 universal inputs • 2 universal outputs DC 0...10 V • For integration into the Siemens Synco living system • Designed for use in heating plants for precontrol of up to 2 room groups - 2 primary controllers each with 1 DC 0...10 V actuator - 1 primary controller with a DC 0.10 V actuator and 1 primary controller with a 3-position actuator With flow and return temperature limitation, optional control of room group pumps and DHW heating. • Suited for control of 3-stage ventilation plant including HR bypass, with influence from humidity, indoor air quality or CO2 level, fault supervision • Forwarding of heat demand signal to primary energy plant Building Technologies

 Open the catalog to page 1
RRV934-2

Equipment combinations The RRV934 multi-controller is designed for use with the Siemens Synco living system. For more detailed information about equipment combinations, refer to the Data Sheet covering the central apartment unit CE1N2707en. Application examples Radiator heating and low-temperature floor heating with flow temperature control, maximum limitation and maintained return temperature Precontrol of 2 independent room groups RRV91x Primary controller Heating circuits room Heating circuits room: Flow temperature sensor Return temperature sensor Room group pump Mixing valve (DC 0…10 V)...

 Open the catalog to page 2
RRV934-3

Integration of ventilation plant 3-stage step selector of ventilation plant HR bypass, 3-position actuator Humidity, indoor air quality or CO2 sensor, DC 0…10 V Fault / maintenance contact (e.g. for monitoring a filter) Exhaust air Outside air Supply air Extract air Ordering When ordering, please give quantity, product name and type reference. Scope of delivery The RRV934 is supplied complete with Mounting Instructions. Product documentation The Operating and Commissioning Instructions for the RRV934 are contained in the product documentation supplied with the central apartment unit. Functions...

 Open the catalog to page 3
RRV934-5

Siemens Building Technologies

 Open the catalog to page 5
RRV934-6

Device and system functions

 Open the catalog to page 6
RRV934-7

Operating and indicating elements Operating elements Indicating element Function of operating elements Function of indicating elements For more detailed information about the functions and operation of the RRV934, refer to the product documentation covering the central apartment unit. Siemens Building Technologies

 Open the catalog to page 7
RRV934-8

Notes on engineering and operation • Due to its compact design, the RRV934 can be fitted directly in the electrical distribution panel*, heat distribution panel*, on the ceiling in the cellar, or in the cable riser • The permissible environmental conditions must be observed • The RRV934 must not be exposed to dripping water • For notes relating to engineering and mounting RF devices of the Siemens Synco living system, refer to Data Sheet CE1N2708en • When mounting the RRV934, ensure that there is sufficient space by the connection terminals to introduce the cable (≥ 30 mm) • At the top of the...

 Open the catalog to page 8
RRV934-9

Technical data Power supply Power consumption (excluding extern. loads) max. 7 VA_ Frequency Range Protocol Typically 30 m inside buildings KNX RF-compatible knx Universal input Permissible cable length to sensor or external contact Universal relay output Measuring range_ Copper cable 0.6 mm dia. Copper cable 1 mm2 Copper cable 1.5 mm2 Type Universal output Electrical connections Type of controller Standards Quantity Type Quantity Screw terminals for Primary controller Environmental compatibility C€ conformity to EMC directive - Immunity, Emissions Low-voltage directive - Electrical safety RTTE...

 Open the catalog to page 9
RRV934-10

Environmental conditions Connection terminals Elevation above sea level min. 700 hPa, corresponding to max. Connection diagram U1, U2 Universal output DC 0...10 V M Ground for universal output X1...X4 Universal input (digital input, sensor input or DC 0.10 V) M Ground for universal input Mains voltage or protective extra-low voltage Q13, Q14 Potential-free universal relay output for AC 24.230 V (relay 1) Q23, Q24 Potential-free universal relay output for AC 24.230 V (relay 2) Q33, Q34 Potential-free universal relay output for AC 24.230 V (relay 3) Potential-free universal relay output for AC...

 Open the catalog to page 10
RRV934-11

Example: Controlled ventilation of apartment: Step selector, HR bypass AC 230 V Multi-controller RRV934 Actuator HR bypass, 3-position AC 230 V Universal output DC 0…10 V Universal input, can be used for temperature measurement / digital input / DC 0…10 V Relay 1 (Q1) of 1-stage step selector Relay 1 (Q1) and relay 2 (Q2) of 2- or 3-stage step selector Relay 1 (Q1), relay 2 (Q2) and relay 3 (Q3) of 3-stage step selector The behavior of relays 1...3 with each stage can be selected on the central apartment unit Multi-controller RRV934 Actuator HR bypass, 3-position, AC 24 V Universal output DC...

 Open the catalog to page 11
RRV934-12

Example of precontrol: Primary controller 1 with actuator, 3-position, AC 230 V, primary controller 2 with actuator, DC 0…10 V Multi controller RRV934 Flow temperature sensor for primary controller 1 (LG-Ni1000) Return temperature sensor for primary controller 1 (LG-Ni1000) Flow temperature sensor for primary controller 2 (LG-Ni1000) Return temperature sensor for primary controller 2 (LG-Ni1000) Room group pump 1 for primary controller 1 Room group pump 2 for primary controller 2 Valve actuator primary controller 1, 3-position, AC 230 V Valve actuator primary controller 2, DC 0...10 V Universal...