PXC5.E003

PXC5.E003
1 / 12 PagesView full catalog

PXC5.E003

Product catalog summary
Overview: The Desigo™ System Controller PXC5.E003 is designed for integrating various devices using BACnet MS/TP, Modbus, and KNX PL-Link. It supports BACnet/IP communication, includes a 2-port Ethernet switch, and offers a WLAN interface for engineering and commissioning. It operates on AC 24 V and can be mounted on standard rails or walls.
Functions: The controller is freely programmable, supporting alarming, scheduling, trending, and access protection. It integrates with other controllers over BACnet/IP, BACnet/SC, or BACnet MS/TP and supports third-party device integration with a generic object viewer via an embedded web interface.
Technical Specifications: The controller supports up to 500 Modbus data points and 60 BACnet/MSTP devices per RS485 interface. It can handle up to 100 BACnet/SC devices and 64 KNX PL-Link devices. It features a compact design for easy mounting and includes interfaces such as Ethernet, Modbus RTU, and BACnet MS/TP.
Installation and Safety: Installation should be in a lockable cabinet or with terminal covers to prevent electric shock, away from areas accessible to children. The operational temperature range is -5 to 50°C. Disposal must comply with local regulations, and it should not be disposed of as domestic waste.
Power Supply: The operating voltage is AC 24 V with a power consumption of 19 VA at full load. It includes internal fusing and requires external supply line fusing.
Interfaces: The controller includes Ethernet, Modbus RTU, BACnet MS/TP, WLAN, and KNX PL-Link interfaces. The WLAN interface supports IEEE 802.11b/g/n standards and can be disabled for security reasons.
Compliance and Standards: The device complies with international standards such as IEC/EN 60730-1, IEC/EN 62368-1, and FCC Part 15, suitable for residential, commercial, and industrial environments.
FCC and Industry Canada Compliance: Compliance with FCC and Industry Canada regulations is emphasized, noting that unauthorized modifications could void user authority. The device must not cause interference and must accept any interference received.
Radiofrequency Radiation Exposure: The equipment complies with radiation exposure limits and should be installed at least 20 cm from the body, not co-located with other transmitters.
Housing and Dimensions: The device is housed in light grey and anthracite grey, with dimensions according to DIN 43880 standards. It weighs 351 g without packaging and 391 g with packaging.
Connection Terminals: Details include RJ45 for Ethernet, KNX PL-Link, operating voltage terminals, and interfaces for Modbus RTU and M-bus.
Warranty: Siemens guarantees technical data only when used with specified Siemens products. Use with third-party products invalidates the warranty.
Contact Information: Issued by Siemens Switzerland Ltd, with contact details and a note that technical specifications are subject to change.
See more

Catalog excerpts

PXC5.E003-1

System controller for integration of BACnet/MSTP, Modbus, and KNX PL-Link devices ● ● ● ● ● ● ● ● ● ● System controller to integrate BACnet MS/TP, Modbus, and KNX PL-Link devices Communication BACnet/IP (BTL certified) 2-port Ethernet switch for low-cost cabling Integration of Modbus data points via RTU and / or TCP Integration of BACnet MS/TP devices KNX PL-Link bus to connect sensors and operator units (including bus power) WLAN interface for engineering and commissioning Operating voltage AC 24 V Mounted on standard rails or on the wall Plug-in screw terminal blocks

 Open the catalog to page 1
PXC5.E003-2

Functions Freely programmable system controller. ● System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories) ● System controller for system networks with PXC3, PXC4, PXC5, PXC7 and DXR controllers over BACnet/IP, BACnet/SC, or BACnet MS/TP ● Integrates third-party devices and systems ● The following functions are available with KNX PL-Link bus: – Communication with room operator units and sensors. ● ● ● ● ● ● ● – Plug-and-play connection of Siemens field devices with KNX PL-Link. Generic object viewer for data points of several...

 Open the catalog to page 2
PXC5.E003-3

Desigo Control Point Description BACnet touch panels with integrated web server Touch panels clients with data storage in web server PXG3.Wx00-1 BACnet/IP web server with standard functionality BACnet/IP web server with extended functionality Technical and mechanical design The compact build allows for mounting the devices on a standard rail or a wall. 5 Plug-in terminal blocks with screw terminals Digital input, for future use Plug-in terminal block with screw terminals M-bus, for future use Plug-in terminal block with screw terminals COM1 / COM2 (MS/TP or Modbus) Plug-in terminal block with...

 Open the catalog to page 3
PXC5.E003-4

Continuously ON Continuously OFF Flashing Link active No connection Network traffic Link 100 Mbps Link 10 Mbps Continuously ON Continuously OFF Flashing Device operational Device not operational Start-up or program halted Continuously OFF Continuously ON Rapid flashing OK HW or SW fault Firmware or application missing/corrupted Connection to the cloud OK No connection to the cloud Optional battery OK Optional battery empty - replace Communication No communication to subsystem Communication No communication to subsystem Flashing per wink command Identification of the device after receipt of wink...

 Open the catalog to page 4
PXC5.E003-5

Product documentation Related documents such as the environmental declarations, CE declarations, etc., can be downloaded from the following Internet address: www.siemens.com/bt/download Notes Safety CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage. ● Observe national provisions and comply with the appropriate safety regulations. Mounting position and ambient temperature The devices can be snapped onto standard rails or screwed onto a flat surface. Plug-in screw terminals connect power and interfaces. Ambient...

 Open the catalog to page 5
PXC5.E003-6

Technical data Power supply Operating voltage (24 V~, ⏊, Functional ground (US) Functional earth The terminal for the functional ground must be connected on the installation side with the building grounding system (PE). Screw terminals for wire cross sections up to Internal fusing External supply line fusing (EU) Non-renewable fuse max. 10 A slow-blow or circuit breaker max. 13 A Tripping characteristic B, C, D per EN 60898 or Power supply with current limitation of max. 10 A Power consumption (for transformer planning) Full load Base load (without loading by KNX PL-Link and M-Bus) M-Bus supply,...

 Open the catalog to page 6
PXC5.E003-7

Screw terminals, plug-in Cu-wire or Cu-strand with wire end sleeve Cu-strand without wire end sleeve Stripping length Slot screws, screwdriver size 1 with shaft ø = 3 mm The two COM interfaces can be used either for Modbus or for MS/TP, according to configuration. Modbus RTU interface Interface type Baud rate 120 Ohm, switchable with DIP switch 270 Ohm pull-up/pull-down resistances, switchable with DIP switch Cabling (in-house cabling only) 3-wire cable, shielded cable recommended (shield must be connected to building earth in the mounting panel) Cable length Short-circuit proof Protection against...

 Open the catalog to page 7
PXC5.E003-8

WLAN interface Interface type Wireless access point Supported standards Frequency band WLAN channels Maximum radio-frequency power Distance (unobstructed field) Device pairing Activation / Deactivation with service button Automatic switch off after 10 minutes if no WLAN-client is connected. Optionally, for cyber security reasons, the WLAN can be permanently disabled via configuration. Default SSID and WLAN password: Scan the QR code. It will show something like WIFI:S:PXC5.E003_0000550;T:WPA;P:1400052738;; Then SSID = PXC5.E003_0000550 and password = 1400052738 Determine manually: Use the information...

 Open the catalog to page 8
PXC5.E003-9

Standards, directives and approvals Product standards Product family standard For residential, commercial, and industrial environments Eurasian compliance UL/cUL approbation (US / Canada) BACnet. Environmental compatibility The product environmental declaration 1) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Documents can be downloaded at http://siemens.com/bt/download. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device,...

 Open the catalog to page 9
PXC5.E003-10

Radiofrequency radiation exposure statement This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. Housing Color top/bottom Dimensions Weight without/with packaging 10 Siemens Schweiz AG Smart Infrastructure RAL 7035 (light grey) / RAL 7016 (anthracite grey)

 Open the catalog to page 10
PXC5.E003-11

Connection terminals Description 2 x RJ45 interface for Ethernet with switch Functional ground must be connected on the installation side with the building grounding system (PE). Digital input (for future use) Interface EIA-485 (Modbus RTU and MS/TP) M-bus interface (for future use) Warranty The application-specific technical data is guaranteed only in combination with the Siemens products listed in the 'Device combinations' section. If third-party products are used, any guarantee provided by Siemens will be invalidated. Siemens Schweiz AG Smart Infrastructure

 Open the catalog to page 11

Archived catalogs

  1. Catalog LV 51

    150  Pages

  2. Gamma instabus

    14  Pages

  3. RRV934

    12  Pages

  4. A6V10575277

    16  Pages

  5. RDS110

    22  Pages

  6. PXC4.M16

    16  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.