Introduction
This document is a catalog from Siemens AG, focusing on components for photovoltaic systems, particularly in low-voltage power distribution. It emphasizes sustainability and Siemens' commitment to providing high-quality, standards-compliant products for energy management.

Specifications and Standards
The catalog stresses the importance of adhering to standards like DIN VDE 0100-712 and VDE 0636-6 for photovoltaic systems to ensure safety and efficiency. It highlights the use of SENTRON devices to meet these standards.

Product Offerings
The catalog lists products for both DC and AC sides of PV systems, including circuit breakers, protective devices, switchboards, and distribution boards.

Photovoltaic Systems Overview
It discusses the growing role of PV systems in the energy mix, describing off-grid and on-grid systems and their benefits.

Functional Principles
The document explains photovoltaic technology principles, including sunlight conversion into electricity and types of PV modules.

Applications and Benefits
Siemens products ensure safe and efficient power distribution in various settings, offering reliable and cost-effective energy management.

Support and Services
Siemens provides extensive support services for planning, operation, and technical support of PV systems.
Overview
PV systems are vulnerable to lightning, necessitating overvoltage protection devices to ensure safety and availability.

Safe Construction and Operation
Guidelines for safe construction and operation are outlined, emphasizing the need for isolating arresters and DC isolators.

Protection Against Overvoltage
Protection devices are necessary on both DC and AC sides to limit voltage spikes.

AC Side Protection
Type B residual current protection devices and miniature circuit breakers are required for transformerless inverters.

Own Consumption of Generated Power
Encourages own consumption with higher tariffs for systems up to 500 kWp, using measuring devices for monitoring.

DC Side Protection
Remote DC isolation is crucial for safety, with string boxes and PV fuses providing protection.

System Design and Protection
Comprehensive protection is required for central inverters, with specific standards for systems over 30 kVA.
Overview: The document provides technical specifications and ordering information for Siemens SENTRON products, focusing on miniature circuit breakers and photovoltaic fuses for DC applications.

Miniature Circuit Breakers:
  • Designed for protection against short circuits and overloads in DC systems.
  • Compliant with EN 60898-2 standards, available in various ratings.

Technical Specifications:
  • Rated voltage: 230/400 V AC, 220/440/880 V DC.
  • Breaking capacity: 10 kA for AC and DC.

Photovoltaic Fuses:
  • Protect PV modules with high rated DC voltage, compliant with IEC 60269-6 and UL 2579.

Benefits:
  • Protection against reverse currents and fault currents.

Ordering Information:
  • Includes part numbers, pricing, and packaging information.

Overvoltage Protection Devices:
  • Protect against overvoltages from lightning or switching operations.
Overview
3VL molded case circuit breakers are designed for switching and protecting the AC output side of central inverters in large PV power plants.

Benefits
  • Modular design with communication options like Modbus RTU and PROFIBUS.

Communication
Enhances start-up, diagnostics, and operation, reducing costs and improving productivity.

Standards and Specifications
Comply with IEC 60947-1, EN 60947-1, and other standards.

Breaking Capacity
Detailed tables for breaking capacities at various voltages.

Operating Conditions
Designed for enclosed areas, with additional technical information available online.
Overview: MCBs protect electrical systems in buildings and industrial applications, safeguarding control circuits in PV inverters.

Specifications:
Approved for use worldwide according to IEC standards.

Benefits:
  • Optional top or bottom infeed, large wiring space, and easy mounting of auxiliary switches.


Technical Specifications:
  • Standards: EN 60898-1, EN 60898-2, EN 60947-2.


Selection and Ordering Data:
Detailed ordering information for various MCB models.
Overview: The document provides information on Siemens SENTRON products for the AC side, focusing on miniature circuit breakers and NEOZED fuse systems.

Miniature Circuit Breakers:
  • Various models with specifications like rated voltage and mounting width.

Technical Specifications:
  • Details on standards compliance and operational characteristics.

NEOZED Fuse Systems:
  • Used in distribution technology and industrial switchgear assemblies.

Ordering Data:
  • Detailed ordering information for various components.
Overview
LV HRC fuse systems are used in non-residential, commercial, and industrial buildings, ensuring safe replacement or isolation of systems.

Specifications and Components
Lists components and accessories for different NH sizes.

Connection Methods
Details specific connection methods for each NH size.

Device Covers and Auxiliary Switches
Provide protection and compatibility with different contact configurations.

Fuse Carriers
Available with standard and electronic monitoring options.

Locking Devices
Ensure safety and reliability in operation.
Overview
The document provides information on LV HRC fuse links and overvoltage protection devices, focusing on specifications, benefits, and ordering data.

LV HRC Fuse Links
Designed with a combination alarm signal for quick identification and replacement.

Technical Specifications
- Operational class: gG
- Rated voltage: Up to 690 V AC / 440 V DC

LV HRC Fuse Bases
Improve heat transmission and reduce temperature.

Overvoltage Protection Devices
Protect against overvoltages from lightning or switching operations.

Technical Specifications for Lightning Arresters
- Standards: IEC 61643-11; DIN VDE 06754-6

Ordering Data
Detailed ordering information for various configurations.
Overview: The document provides technical specifications and ordering information for Siemens SENTRON overvoltage protection devices.

Technical Specifications: Lists models with standards, approvals, and critical parameters.

Product Variants: Categorizes products based on application and system compatibility.

Selection and Ordering Data: Detailed ordering information for various configurations.

Surge Arresters Type 2 and 3: Protect against transient overvoltages.

Accessories: Lists plug-in parts for flexibility and customization.

Applications: Suitable for protecting low-voltage systems and ensuring safety.
Specifications:
Outlines specifications for Siemens SENTRON measuring and monitoring devices, including the 7KT PAC and 7KM PAC series.

Procedures and Usage:
Guidance on selection and ordering of measuring devices and expansion modules.

Norms and Standards:
Devices comply with various standards and are designed for specific mounting.

Recommendations and Best Practices:
Suggests using the 7KM PAC series for precise energy measurement.

Technical Data and Ordering Information:
Provides detailed technical specifications and ordering information for various models.
Overview: The document provides technical specifications and information about Siemens' SENTRON measuring and monitoring devices.

Specifications: Designed for control panel flush-mounting with wide voltage range support.

Connection Types: Offers different terminal connections for current and voltage.

Expansion Modules: Details various expansion modules for enhanced communication capabilities.

Current Transformers: Describes window-type and pin-wound transformers.

Ordering Information: Provides detailed ordering information for various models and accessories.

Additional Resources: References additional manuals and resources for further technical information.
Overview: The document provides technical specifications and product information for Siemens' SENTRON measuring and monitoring devices.

Residual Current Monitors (RCMs): Detect residual currents and issue signals when currents exceed set values.

Voltage and Frequency Relays: Monitor grid status and ensure disconnection upon violation of set limits.

ALPHA 8HP Molded-Plastic Distribution System: Offers modular design for control panels and low-voltage distribution boards.

Technical Specifications and Ordering Information: Provides detailed specifications and ordering information for each product type.
Technical Specifications
Outlines specifications for Siemens' LV 11 distribution system, focusing on rated current and busbar dimensions.

Electrical and Physical Characteristics
Designed to operate at specific voltages with high resistance materials.

Installation and Environmental Conditions
Specifies conditions for different environments.

Standards and Certifications
Complies with several standards and has passed special tests.

Enclosure Features and Ordering Information
Provides information on enclosure features and ordering data.

Accessories and Modular Devices
Details accessories and modular installation devices.
Overview: The document provides specifications and ordering information for Siemens ALPHA FIX Terminal Blocks.

Specifications:
  • Terminal Sizes: Covers sizes from 4 mm² to 240 mm².
  • Material and Standards: CUUS certified and compliant with IEC standards.

Accessories:
  • Covers, compartment partitions, warning covers, reducing combs, labels, and retainers.

High-Current Terminals:
  • Available from 50 mm² to 240 mm² with specific accessories.

Ordering Information: Lists order numbers, prices, and packaging details.
Overview: The document is a technical catalog from Siemens AG, detailing specifications and ordering information for ALPHA FIX Terminal Blocks.

Product Specifications: Provides specifications for various terminal blocks.

Standards and Approvals: Conforms to IEC standards and designed for the UL market.

Ordering Information: Outlines the ordering process and logistics.

Logistics and Packaging: Emphasizes quality logistics services.

Additional Resources: References further technical information available online.
Overview: This document provides comprehensive support and information for Siemens low-voltage power distribution products.

Online Resources: Access to catalogs, brochures, and software trial versions.

Quality Management: Adheres to ISO 9001 standards.

Standards and Approvals: Lists various international standards applicable to Siemens products.

Marine and CE Marking: Products comply with marine classification societies' specifications.

Accident Prevention: Devices have test certificates for safety control systems.
Standards and Approvals
Outlines various international standards and approvals required for Siemens products.

Type Overview of Approved Devices
Categorizes devices based on approval status.

Siemens Contacts and Online Services
Provides support and information through online platforms.

Service and Support
Offers comprehensive service and support globally.

Software Licenses
Details conditions for software licenses and usage rights.
Software Licensing and Updates
Siemens software requires a Certificate of License (CoL) for use, with updates available through PowerPack and Upgrade versions.

PowerPack
Allows upgrading to more powerful software.

Upgrade
Permits using a new software version if a previous version license is held.

ServicePack
Debugs existing products.

License Key
Acts as electronic stamps and activation switches.

Software Update Service (SUS)
Provides free software updates for one year.

Additional Information
Further details on license conditions available online.
General Terms and Conditions: For customers in Germany, specific terms apply, with distinct licensing conditions for software products.

Specifications: Dimensions are provided in millimeters, with prices in Euros.

Export Regulations: Siemens is not obligated to fulfill agreements hindered by trade restrictions.

Product Catalog: Includes a wide range of products for various applications.

Disclaimer: Product descriptions may change due to ongoing development.
See more

Catalog excerpts

Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-1

Standard-Compliant Components for Photovoltaic Systems SENTRON • SIVACON • ALPHA Answers for infrastructure and cities.

 Open the catalog to page 1
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-2

Related catalogs Low-Voltage Power Distribution and LV 10.1 Electrical Installation Technology SENTRON Protection, Switching, Measuring and Monitoring Devices Air circuit breakers Molded case circuit breakers Miniature circuit breakers Residual current protective devices / AFD units Fuse systems Overvoltage protection devices Switch disconnectors Switching devices Transformers, power supply units and socket outlets Busbar systems Measuring devices and power monitoring Monitoring devices Software Switchboards Busbar trunking systems System cubicles, system lighting and system air-conditioning...

 Open the catalog to page 2
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-3

SENTRON · SIVACON · ALPHA Standard-Compliant Components for Photovoltaic Systems SENTRON Products for the DC Side SENTRON Products for the AC Side SENTRON Measuring and Monitoring Devices SIVACON · ALPHA Distribution Systems and System Cubicles ALPHA FIX Terminal Blocks The products and systems listed in this catalog are developed and manufactured using a quality management system certified by VDE and according to EN ISO 9001:2000. Supersedes: Catalog LV 11 · 2012 Refer to the Industry Mall for current updates of this catalog: www.siemens.com/industrymall The products contained in this catalog...

 Open the catalog to page 3
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-4

The right one for everyone Our portfolio includes switchboards, busbar trunking systems, distribution boards, protection, switching, measuring and monitoring devices, building management systems, switches and socket outlets. All over the world, the universality, modularity and intelligence of our components and systems give you innumerable benefits – all the time they are in use. Developed according to the respective international standards, we offer forwardlooking design with innovative functions and ensure the highest quality standards world-wide. Sustainability in focus As a worldwide leader...

 Open the catalog to page 4
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-5

Universal, safe and intelligent power distribution Whether in industrial plants, in infrastructure or in buildings: Each technical plant depends on the reliable supply of electricity. Even a short outage can have grave consequences. We offer the best technology for the responsible use of electrical energy and at the same time help to protect people and property and to conserve natural resources. We are happy to help you with comprehensive support from the initial information through to operation. Take a closer look at all the options available from Siemens. Everything for power distribution Excellent...

 Open the catalog to page 5
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-6

with just one click specific information technical information. Download Center - Picture Database - Industry Mall - SIMARIS Software - Technical Support - Service & Support - Support Request Always at your service support, from planning

 Open the catalog to page 6
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-7

Perspectives on the supply of energy Photovoltaic systems in focus Photovoltaic application areas Sunlight becomes electricity Safely disconnected and reliably protected The right solution for every application

 Open the catalog to page 7
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-8

Perspectives on the supply of energy Fossil fuels are growing scarcer, energy is becoming more and more expensive, and global warming is increasing dramatically due to rising greenhouse gas emissions – all these trends are forcing energy policy to be rethought. A decade has already passed since the European Parliament ratified Directive 2001/77/EC, “Promotion of electricity from renewable sources,” in September 2001. In conjunction with the goals of the Kyoto Protocol in regard to worldwide reduction of CO2 emissions, the proportion of renewable energy relative to the overall energy mix is to...

 Open the catalog to page 8
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-9

Photovoltaic systems in focus Photovoltaic in the energy mix Standards promote safety Interest in photovoltaic systems (PV systems) is steadily increasing – due not just to ecological factors but to economic factors as well. PV systems are profitable not least due to the infeed tariffs guaranted by local laws (e.g. German Renewable Energy Sources Act – EEG). A PV system needs to be safely constructed and operated according to the DIN VDE 0100-712, E DIN IEC 60269-6, and VDE 0636-6 installation standards. That is the only way to ensure the safety of persons and buildings and ultimately the long-term...

 Open the catalog to page 9
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-10

Photovoltaic application areas Highlights 7 Autonomous power supply through off-grid systems Grid-compliant energy infeed with on-grid systems A broad range of applications with power spans up to the megawatt range System types On-grid systems The market for PV systems is broken down into off-grid (< 1 kW) and on-grid systems. For on-grid systems, a differentiation is made between residential (1 – 10 kW) and commercial (10 – 500 kW) systems as well as power plants (> 500 kW). In the case of on-grid systems, the power is fed into the public electricity grid. The DC voltage generated by the PV...

 Open the catalog to page 10
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-11

Sunlight becomes electricity Functional principle The term photovoltaic describes the direct conversion of radiant energy such as solar energy into electrical power. The conversion takes place using PV cells in PV systems. The electricity generated can be used on-site, stored in accumulator batteries, or fed into the power grid. Set-up of the PV generator Several PV cells are combined to form a PV module. The module voltage is typically up to 40 V. All PV modules taken together form a PV generator. PV modules are available in three versions: • Monocrystalline modules with efficiency of 15 to...

 Open the catalog to page 11
Catalog LV 11 - 2013 - Standard-Compliant Components for Photovoltaic Systems-12

Safely disconnected and reliably protected Highlights 7 Internationally approved products for the construction of standard-compliant PV-systems Safe disconnection of the PVgenerator and the system from the grid on all poles – e.g. for maintenance work Protection against lightning and overvoltage on the DC as well as on the AC side Safe construction and operation The safe construction and operation of a PV system is of great importance, particularly for the system’s long-term profitability. The guidelines for installation and operation of PV systems can be found in DIN VDE 0100-712 and IEC 60364-7-712....

 Open the catalog to page 12

Archived catalogs

  1. Catalog LV 51

    150  Pages

  2. Gamma instabus

    14  Pages

  3. RRV934

    12  Pages

  4. A6V10575277

    16  Pages

  5. RDS110

    22  Pages

  6. PXC4.M16

    16  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.