Installation OverviewThis document provides installation instructions for Siemens Building Technologies' BC43, BC34-EM, and BC43-Cotag systems. These systems are part of the SiPass Entro security solution, designed for use with door controllers DC22, DC12, and DC800.
Connection Instructions- BCLink Connection: Establish a connection between the door controller (DC22 or DC12) and the BC4 magnetic card reader or BC4 Prox/EM proximity reader, with a maximum distance of 100 meters.
- Entry/Exit Configuration: Set the link to 'Entry' if the BC4 is used for entrance and 'Exit' if used for exit.
- Tamper Switch Control: Set links to 'Internal' when part of a SiPass Entro system, prohibiting connections on terminals 5 and 6. Set to 'External' when connected to BC45/40 systems.
- Screen Connection: Connect the screen for long distances or in environments with potential interference.
- External Tamper Switch: Terminals 5 and 6 are for external tamper switch connections, used only in Bewacard installations.
Technical Specifications- Power Supply: 1-14V AC/DC.
- Current Consumption: BC4: 50 mA; BC4 Prox & BC4 EM: 100 mA.
- Temperature Range: BC4: -5°C to +50°C; BC4 Prox & BC4 EM: 0°C to +50°C.
- Dimensions: 160 x 108 x 47 mm.
Additional InformationFor connections to older door controllers, refer to the Siemens website. The document notes that data and design are subject to change without notice, and supply is subject to availability.