1. Catalogs
  2. SIEMENS Building Technology
  3. AGB600 - Audio glass break detector

AGB600 - Audio glass break detector

AGB600 - Audio glass break detector

AGB600 - Audio glass break detector

Product catalog summary
Product Overview: The AGB600 is an audio glass break detector designed by Siemens Building Technologies. It features a unique signal analysis based on a neuronal network, providing high immunity to false alarms and ensuring maximum detection reliability. This makes it suitable for various applications, including commercial, residential, and public buildings.
Key Features:
  • Operating radius up to 8.5 meters.
  • Signal analysis based on a neuronal network for false alarm immunity.
  • Acoustic function check using the GT2 glass break simulator.
  • Optimized for single or multiple glazed objects with simple window glass.
  • Small and unobtrusive housing for easy wall or ceiling mounting.
Technical Specifications:
  • Supply Voltage: 8.0 to 16.0 VDC (12V nominal).
  • Current Consumption: 3.2mA (quiescent), 8mA (maximum with LED).
  • Alarm Output: Semiconductor relay, 30VDC / 100mA, 2.5s holding time.
  • Coverage Area: Max 8.5m radius, sensitivity adjustable.
  • Approved Glass Type: Float glass, 3mm to 6mm thickness.
  • Ambient Conditions: Operating temperature -10 to +55°C, storage temperature -20 to +60°C, humidity < 95% r.h., non-condensing.
  • Housing Protection: IP31 / IK02.
Installation and Testing: The detector can be tested using the GT2 glass break simulator, ensuring the entire operating radius is controllable. It is designed for fast and simple installation, with two settings for accurate adjustment to the environment.
Approvals and Ordering Information:
  • VdS Class B approved, no. G 103505.
  • Part Number: AGB600 (Audio glass break detector), GT2 (Glass break simulator).
  • Weight: AGB600 - 0.150kg, GT2 - 0.250kg.
See more

Catalog excerpts

AGB600 - Audio glass break detector-1

Operating radius up to 8.5m Signal analysis based on a neuronal network Detector can be tested by using the glass break simulator GT2 Acoustic function check of the whole covered area Optimised for single or multiple gazed objects fitted with simple window glass To do its unique signal analysis based on a neuronal network, the AGB600 is immune to false alarms by maximum detection reliability. That fact makes it ideally suited for use in a wide range of applications, including commercial and residential premises, public buildings and similar locations requiring stringent security. Outstanding false alarms immunity and fast and simple installation A comprehensive protection concept makes the detector insensitive to environmental disturbances such as traffic, ringing, whistling, sources of ultrasound and electro-magnetic interference. ֖ Thanks to its small and unobtrusive housing, the detector can be mounted onto walls and ceiling. The AGB600 is equipped with two settings for an accurate adjustment to the application and environment. With the help of the acoustic glass break simulator GT2, the whole operating radius (up to 8.5m) is completely controllably. > Siemens Building Technologies size="-1">

 Open the catalog to page 1
AGB600 - Audio glass break detector-2

Coverage area and dimensions > 23mm 60mm min. 0,2m min. 0,2m r = 8,5m max. 8,5m min. 1,0m max. 8,5mmin. 1,0m 120 80mm min. 1,0m 2m4m6m8m 2m4m6m8m 6m4m2m 8m 0 Technical data Supply voltage > DC (12V nom.) > Ж Voltage monitoring 8.0 16.0V Alarm at < 3.5V ű 0.5V Current consumption (at 8 16V > DC ) > Ŗ Quiescent > Maximum (with LED) 3.2mA 8mA Alarm Output > ֖ Semiconductor relay (opens on alarm) > DC / 100mA / R > i <40 ohmic load 2.5s > Alarm holding time 30V Tamper contact 30V > DC / 100mA (ohmic load) RESET input LOW 1.5V / HIGH 3.5V Coverage area > ֖ Range > Sensitivity setting > ֖ Size of the...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.