video corpo

Q-SERIES

Q-SERIES
1 / 26 PagesView full catalog

Q-SERIES

Product catalog summary
Safety Information:
Ensure the fixture is powered off and unplugged before maintenance. Proper electrical grounding is essential, and damaged cables should be avoided. Install in well-ventilated areas, maintaining a clearance of 0.3 m around cooling fans. For outdoor setups, use corrosion-resistant hardware and safety cables. The device is for professional use and must be installed by knowledgeable personnel.
Overview:
The Q-7 Series is an IP65/IP66-rated LED flood light suitable for various applications, including wireless operation environments. It features high-power RGBW or cool white LEDs, low power consumption, and supports RDM and DMX control standards.
Installation and Rigging:
The Q-7 Series can be installed in any orientation with locking points for secure mounting. Use supplied omega brackets and ensure all fasteners are tightened. Consider rain shields for outdoor installations and use safety wires rated for at least 10 times the fixture's weight.
Power Connection:
Operates on 208–240 V, 50/60 Hz AC power supply. Ensure proper grounding and use a fuse or circuit breaker for protection. For outdoor installations, use suitable connectors or have a qualified electrician wire the mains cable directly.
Device Configuration:
The device supports DMX control and standalone operation, featuring dimming, color mixing, and adjustable color temperature correction.
Maintenance:
Regular maintenance is required for optimal performance. Follow manufacturer's guidelines for cleaning and servicing.
Accessories and Support:
Optional accessories include barndoors, color frames, and anti-glare shields. For support, contact the hotline or visit the manufacturer's website.
Specifications and Installation:
Standard type C circuit breakers should be used, with a maximum of 4 fixtures on a 10A breaker and 7 on a 16A breaker. The fixture must be grounded and isolated from AC power, incorporating a fuse or circuit breaker for protection.
Connecting AC Power:
Power connection involves live, neutral, and ground wires with specific color coding. The fixture can be tilted between 0° and 190° without special tools.
Operational Modes and Configuration:
The Q-7 Series operates in DMX and standalone modes. The OLED display shows the current mode, DMX address, and external data protocol. Configuration can be done via the control panel or RDM for POI versions.
DMX Control and Wireless Operation:
Supports both cabled and wireless DMX control. A CRMX wireless receiver is recommended for long-range use. Up to 32 fixtures can be connected on the same DMX link.
Standalone Operation:
Can run standalone programs with up to 24 scenes. Standalone mode is enabled through the menu, and programs can run automatically on startup.
Color Calibration and Dimming:
Offers full color calibration and color temperature correction. The dimming curve can be set to linear or gamma corrected.
Additional Features:
The OLED display can be flipped for easier reading when installed upside down. The display dims or turns off when not in use to save power.
Display Settings:
Configuration of display settings is emphasized to prevent deterioration. Adjust settings via SETTINGS → DISPLAY SAVER.
Fan Mode:
Fan speed can be adjusted for low-noise environments or high temperatures through SETTINGS → FAN MODE.
LED Refresh Rate:
To prevent flickering with cameras, adjust the LED refresh rate in SETTINGS → REFRESH RATE.
Fixture Personality Settings:
Restoring factory defaults sets parameters like DMX address, dimming curve, and fan mode.
RDM Functions:
Supports RDM for configuration and monitoring, with a table listing supported functions and sensor types.
Troubleshooting:
Common issues and remedies are provided, such as checking power connections and DMX settings.
POI Version:
Designed for outdoor use, the POI version lacks a display and requires RDM for configuration.
Installation and Rigging:
Instructions for adjusting the tilt angle using a spanner and pig-nose keys are provided.
DMX and AC Power Connection:
DMX in and out are integrated into the same cable. For permanent installations, a qualified electrician should wire the mains cable directly.
Accessories:
Supports various accessories like barndoors, color frames, and anti-glare shields.
Firmware and Maintenance:
SGM USB to DMX cable is used for firmware updates. Regular cleaning of the front lens and exterior housing is advised.
Ordering Information:
Available in various models and colors, with numerous accessories. Contact local SGM dealers for pricing.
Support and Compliance:
SGM offers 24/7 technical support. The fixtures conform to several EU directives and standards.
See more

Catalog excerpts

Q-SERIES-2

All dimensions in millimeters and inches. Drawing not to scale. This manual covers installation, use, and maintenance of the SGM Q-7 Series. A digital version is available at www.sgmlight.com or upon request via [email protected]. Q-7 SERIES USER MANUAL REV. E © 2018 SGM Light A/S®. The information in this document is subject to change without notice. SGM and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss, or any other loss occasioned by the use of, inability to use, or reliance on the information contained in this...

 Open the catalog to page 2
Q-SERIES-4

Safety information Read the following safety precautions carefully before unpacking, installing, powering, or operating the device. SGM luminaries are intended for professional use only. They are not suitable for household use. Les luminaires SGM sont impropre à l’usage domestique. Uniquement à usage professionnel. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Ce produit doit être installé selon le code d’installation pertinent, par une personne qui connaît bien...

 Open the catalog to page 4
Q-SERIES-5

The Q-7 Series is an IP65/IP66-rated LED flood light with a small footprint and high output, designed for multiple applications, including when wireless operation is essential (POI n.a.). Q-7 Series features: • A flood light, weighing only 8.1 kg/17.9 lbs. • Multi-environmental luminaire due to its IP65/IP66-rating that enable operation in all kinds of environmental settings and in temperatures from -40 °C to 50 °C. • 2000 high-power RGBW (Q-7) / 1000 high-power cool white LEDs (Q-7W), with an expected lifetime of 50,000 hours*. • Low power consumption. • Diming and color mixing (Q-7/Q-7 POI...

 Open the catalog to page 5
Q-SERIES-6

Preparing for installation Unpacking Unpack the device and inspect it to ensure that it has not been damaged during transport. The Q-7 Series are shipped with: • • • • • • 2 x Omega brackets with 1/4-turn fasteners (standard only). 1 x Mounting bracket with fasteners (standard only). 1 x Omni / CRMX™ Antenna (standard only). 1 x Spanner with magnet (POI only). 4 x M-10 screws (POI Only). Safety information leaflet. Location / application The standard fixture is IP65-rated and is designed for both indoor and outdoor events. This means that it is protected from: • Dust, to the degree that dust...

 Open the catalog to page 6
Q-SERIES-7

Rigging process using the SGM Omega brackets Start the standard rigging process by blocking the lower working area, and make sure the work is performed from a stable platform. 1. Check that the clamp/bracket is undamaged and can bear at least 10 times the weight of the fixture. Check that the structure can bear at least 10 times the weight of all installed fixtures, lamps, cables etc. 2. Bolt the clamp/bracket securely to the omega bracket with a M12/ ½ bolt (min. grade 8.8 C5M) and a lock nut. 3. Align the omega bracket with the Q-7 Series base. For standard Omega Bracket, insert the fasteners...

 Open the catalog to page 7
Q-SERIES-8

Tilt lock The fixture can be tilted from 0° - 190°. In Q-7 standard versions, there is no need for any special tools to adjust the tilt angle. Follow the steps below for adjusting the tilt in standard Q-7: 1. Loosen the two tilt screws (one on each side) by turning them counter-clockwise. 2. Tilt the fixture to the angle desired and hold it. 3. Lock the position by re-tightening both tilt lock screws clockwise. If you feel resistance when tilting the fixture, you might not have loosened the tilt screws enough. CAUTION!! If the fixture has been operating, always allow it to cool for 15 minutes...

 Open the catalog to page 8
Q-SERIES-9

Configuring the device The Q-7 Series can be set up by using the control panel and OLED multi-line display at the base of the fixture or through RDM. Please note: In POI versions there is no display mounted in the fixture. The adjustments are made through RDM. See page 19 for more information. The OLED display is the human interface of the fixture as it displays the current status and menu of the fixture. The display panel can be used to configure individual fixture settings, check the fixture’s wireless status, confirm the firmware version, and read error messages. The complete list of the menu...

 Open the catalog to page 9
Q-SERIES-10

Connecting to a DMX control device The Q-7 Series is controllable using a DMX control device, and it can be connected using either a DMX cable, or via the fixture’s built-in CRMX wireless receiver system. When using a cabled DMX system, connect the DMX-In cable (with male 5-pin XLR plug) to the input connector and DMX-Out cable (with female 5-pin XLR plug) to the output, both located on the rear of the fixture’s base. For outdoor installations, use only IP-rated XLR connectors suitable for outdoor use. Terminate the DMX out cable of the last fixture in the data link with a 120 ohm DMX termination....

 Open the catalog to page 10
Q-SERIES-11

Configuring the device for DMX control About DMX The Q-7 Series can be controlled using signals sent by a DMX controller on a number of DMX channels. DMX is the USITT DMX512-A standard, based on the RS-485 standard. The signal is sent as DMX data from a console (or a controller) to the fixtures via a shielded twisted pair cable designed for RS-485 devices. The cables can be daisy chained between the fixtures, and up to 32 fixtures can be connected on the same DMX link. Up to 300 m. (1000ft.) of cable is achievable with high quality DMX cables. All DMX links must be terminated by connecting a...

 Open the catalog to page 11
Q-SERIES-12

Full Color Calibration and Color Temperature Correction (Q-7 only) Most DMX channels: possibility to choose between raw or white-calibrated color (6500K default) via the Control Menu (SETTINGS → WHITE CALIBRATED). RGB DMX modes: features full color calibration (irrespective of current color setting) when 2 or 3 colors are mixed, to ensure uniform color mixing between products. Adjusting 1 color does not activate full color calibration. RGB + CTC DMX modes: features full color calibration (irrespective of current color setting) when 2 or 3 colors are mixed, to ensure uniform color mixing between...

 Open the catalog to page 12

All SGM Light catalogs and technical brochures

  1. i·5 RGBW POI

    7  Pages

  2. i·5 UV POI

    6  Pages

  3. Q·7 W POI

    6  Pages

  4. P-SERIES

    24  Pages

  5. I-SERIES

    24  Pages

Archived catalogs

  1. P-5

    44  Pages

  2. PILOT 3000

    116  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.