P-5
44Pages

{{requestButtons}}

Catalog excerpts

P-5 - 1

P-5 P-5 WHITE P-5 TUNABLE WHITE

Open the catalog to page 1
P-5 - 2

All dimensions in milimeters and inches.

Open the catalog to page 2
P-5 - 3

P-5 WASH LIGHT USER MANUAL REV. 4C © 2014 SGMTM. Information subject to change without notice. SGM and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. The SGM logo, the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are trademarks owned or licensed by SGM or its affiliates or subsidiaries. This edition applies to...

Open the catalog to page 3
P-5 - 6

Safety information WARNING! Read the safety precautions in this section before installing, powering or operating this product. P-5 series luminaires are intended for professional use only. They are not suitable for household use. Review the following safety precautions carefully before installing or operating the device. Preventing electric shock DANGER! Risk of electric shock. Do not open the device. • • • • • Do not open the device; there are no user-serviceable parts inside. Ensure that power is cut off when wiring the device to the AC mains supply. Ensure that the device is electrically...

Open the catalog to page 6
P-5 - 7

WARNING! Take measures to prevent burns and fire. • • • • • • • • Install in a location that prevents accidental contact with the device. Install only in a well-ventilated space. Install at least 0.3 m (12 in.) away from objects to be illuminated. Install only in accordance with applicable building codes. Ensure a minimum clearance of 0.1 m (4 in.) around the cooling fans. Do not paint, cover, or modify the device, and do not filter or mask the light. Keep all flammable materials well away from the device. Allow the device to cool for 15 minutes after operation, before touching it. WARNING!...

Open the catalog to page 7
P-5 - 8

Overview P-5, P-5 W and P-5 TW luminaires are DMX-controllable, low-profile, IP65-rated, rectangular, LED wash lights. The standard P-5 offers full RGBW color mixing, color temperature control and incorporate 44 10 W LZ4 RGBW Cool White Emitter LED’s. The P-5 W (white) is similar, but incorporating white-emitting LEDs. The P-5 TW (tunable white) offers the ability to adjust white color temperature to 2200, 3000, 4000 or 5300 K. The fixtures all provide built-in wireless DMX support, stand-alone programs, dimming, and a lamp life expectancy of 50,000 hours. Three P-5 lens options are...

Open the catalog to page 8
P-5 - 9

Preparing for installation Unpack the device and inspect it to ensure that it has not been damaged in transport. The P-5 is shipped with two quarter-turn brackets that can be used to mount the device at elevation, and a W-DMXTM G4 wireless antenna. The fixture has an ingress protection rating of IP65. This means that it is protected from: • • Dust, to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation. Lower pressure jets of water from any direction. When selecting a location for the device, ensure that it: • • • Is situated away from...

Open the catalog to page 9
P-5 - 10

The P-5 may be installed in any Orientation. Dimensions in milimeters and inches For permanent installation on the ground, f" 300 <11 * h"> ^ remove the rubber feet from the floor stand/base. Fasten securely through the 155 resulting holes with four 6 mm (1/4 in.) (6-1 in-) corrosion-resistant mechanical fasteners J^- Two quarter-turn brackets are supplied with the device if it is to be flown above the ground. Remove the floor stand/base and rig the P-5 to a support truss or structure using the supplied brackets and suitable clamps. Fasten a safety cable (not shown) between the support...

Open the catalog to page 10
P-5 - 11

WARNING! Always secure an elevated P∙5 with a safety cable as backup The device can be tilted from -10/+100 degrees. To adjust the tilt angle, loosen the two tilt screws, one of each side of the fixture, tilt the device to the angle required and retighten the screws. If installed horizontally with a downward beam-angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. If the device has been operating, always allow it cool for 15 minutes before handling.

Open the catalog to page 11
P-5 - 12

Connecting AC power The P·5 can operate on any 208–250 V, 50/60 Hz AC mains power supply. It draws approximately 2 amps at full power. For permanent installation, have a qualified electrician wire the mains cable directly to a suitable branch circuit. The junction’s ingress protection (IP) rating must be suitable for the location. For temporary installation, the mains cable may be fitted with a grounded connector intended for exterior use. The power cable color coding is given in the table. • Connect the black wire to live • Connect the white wire to neutral • Connect the green/yellow wire...

Open the catalog to page 12
P-5 - 13

Configuring the device Set up the fixture using the control panel and OLED display at the rear of the fixture. Navigate the menus and options using the arrow buttons and select items using the Enter button. The options available are listed in “Control menu” on page 32. After powering the P-5 on, the display shows the currently selected operating mode and other information. A - Operational mode (Quick color, stand-alone or DMX mode) B - DMX address (if DMX mode is active) C - External data indicator (if DMX control is active) D - External data protocol (W-DMX or DMX) The fixture is set by...

Open the catalog to page 13
P-5 - 14

Setting a static color manually The device can be configured to display a predefined and static color (or white, depending on the P-5 model) using the “Manual→Quick color” menus (see “Control menu” on page 32). Note that whenever the “Manual→Quick color” settings are changed, the fixture will be set by default to automatically start in quick color mode whenever it is powered on. This can be reset using the “Settings→Startup mode→Select startup mode” (see “Control menu” on page 32).