Catalog excerpts
G‐WASH MOVING HEA
Open the catalog to page 1Measurements in millimetres and inches (in parentheses). Drawing not to scale
Open the catalog to page 2G‐WASH USER MANUAL © 2017 SGM Light®. Informations are subject to change without notice. SGM and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. The SGM logo, the SGM Light name and all other trademarks in this document pertaining to services or products by SGM Light or its affiliates and subsidiaries are trademarks owned or licensed by SGM Light or its affiliates or subsidiaries. The original...
Open the catalog to page 3Safety information WARNING! Read the safety precautions in this section before unpacking, installing, powering or operating this product. The G-Wash is intended for professional use only. It is not suitable for household use. Impropre a l’usage domestique. Review the following safety precautions carefully before installing or operating the fixture. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Ce produit doit être installé selon le code d’installation...
Open the catalog to page 8Preventing burns and fire WARNING! Take measures to prevent burns and fire. • Install in a location that prevents accidental contact with the fixture. • Install only in a well-ventilated space. • Install at least 0.3 m (12 in.) away from objects to be illuminated. • Install only in accordance with applicable building codes. • Ensure a minimum clearance of 0.1 m (4 in.) around the cooling fans. • Do not paint, cover or modify the fixture. • Keep all flammable materials away from the fixture. • Allow the fixture to cool for 15 minutes after operation, before touching it. CAUTION:...
Open the catalog to page 9Avoid personal injury WARNING! Take measures to prevent personal injury. • Do not look directly at the light source from close range. • Take precautions to prevent injury when working at height. • Ensure that the fixture is always securely fastened with suitable hardware. • For elevated installations, secure the fixture with suitable safety cables, and always comply with relevant load dimensioning, safety standards and requirem
Open the catalog to page 10Overview The SGM G-Wash is a maintenance free, multi-environmental moving head luminaire. It is IP-65-rated and can operate in all kinds of weather. It has a powerful LED light source with high output and a virtually unlimited color palette, a Fresnel lens, optical zoom, elliptical beam shaper and can easily be controlled by wired and wireless DMX. The fixture also offers RFID / NFC, low power consumption and an expected lifetime of the multiple LED’s of 50,000 hours*. * At 70% of luminous output under the manufacturer’s test condition
Open the catalog to page 11A : Pan lock B : Tilt lock C : Base handle D : Head fan grill (one of two shown) E : Display panel F : Safety wire attachment point G : Fuse H : DMX in I : DMX out J : Power in K : Power cord
Open the catalog to page 12Preparing for installation Unpacking Unpack the fixture and inspect it to ensure that it has not been damaged in transport. The G-Wash is shipped with: • User manual. • One Neutrik TRUE1 power input connector, 2 m (78 in.) • Two Omega brackets with 1/4-turn fasteners
Open the catalog to page 13Location/application The fixture is IP-65-rated and designed for use in wet locations. This means that it is protected from: • Dust; to the degree that dust cannot enter the fixture in sufficient quantities to interfere with its operation. • Lower pressure jets of water from any direction. When selecting a location for the fixture, ensure that: • It is situated away from public thoroughfares and protected from contact with people. • It is not immersed in water or exposed to high-pressure water jets. • It has adequate ventilation. When using the fixture outdoors or in wet locations,...
Open the catalog to page 14Installation / Rigging WARNING! Always secure elevated fixtures with a safety cable. The G-Wash may be installed in any orientation. Always use two Omega brackets to rig the fixture. Lock each bracket with both 1/4-turn fasteners. The fasteners are locked only when turned fully clockwise. Always fasten safety cables between the load-bearing support structure and the attachment points on the fixture. The safety cables must be able to bear at least 10 times the weight of the fixture. CAUTION: • Always use two safety wires. • Min. safety wire gauge = 5 mm. • Max. safety wire length (free...
Open the catalog to page 15Rigging process Start the rigging process by blocking the work area below, and make sure the work is performed from a stable platform. Check that the clamps are undamaged and can bear at least 10 times the weight of the fixture. Check that the structure can bear at least 10 times the weight for all installed fixtures, clamps, cables etc. Bolt each clamp securely to an Omega bracket with an M12 / ½” bolt (min. grade 8.8) and lock nut. Align an Omega bracket with two 1/4-turns in the base. Insert the fasteners into the base and turn both levers a full 1/4-turn clockwise to lock. Install the...
Open the catalog to page 16The G-Wash can operate on any 100-240V, 50/60 Hz mains power supply. Connect the fixture to power using a cable with a Neutrik powerCON TRUE1 connector (supplied with the fixture). (POI fixtures are supplied with a fixed-chassis mounted, bare-ended power cable for installation in, for example; an weather-resistant junction box.) The fixture must be grounded/ earthed and be able to be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
Open the catalog to page 17Control panel operations The display panel can be used to configure individual fixture settings, check the fixture’s wireless status, firmware version and error messages. When the fixture is powered on, it boots and resets, before displaying the DMX start address. Using the control panel • Press the ‘UP’ / ‘DOWN’ arrows to set the DMX start address. Confirm by pressing ‘OK’, cancel by pressing ‘ESC’. Press the ‘OK’ button to enter a menu or make a selection. Press the arrow buttons to scroll up and down the menus. Press the ‘ESC’ button to take a step back. Press the ‘UP’ and ‘DOWN’ arrows...
Open the catalog to page 18All SGM Light catalogs and technical brochures
-
G·4 Wash-Beam
6 Pages
-
i·5 RGBW POI
7 Pages
-
i·5 UV POI
6 Pages
-
Q·7 W POI
6 Pages
-
Q-SERIES
26 Pages
-
P-SERIES
24 Pages
-
I-SERIES
24 Pages
-
SGM SAFETY INFORMATION
8 Pages
Archived catalogs
-
IDEA MOVING LED 300
22 Pages
-
P-5
44 Pages
-
X-5 / XC-5 LED Strobe
28 Pages
-
Studio 12 scan control
62 Pages
-
PILOT 3000
116 Pages