Catalog excerpts
Acid etched glass for architecture and decoration SATIN Technical Specifications Different opacities, luminosities and finishes allow you to choose its level of luminosity and light diffusion, smooth to the touch, brilliance, resistance to stains and an antireflection action for a sustainable use in most versatile applications: architectural, interior design and furniture. SatenGlas® SatenLux® LuxMat® Measurements and parameters stated by the Ift Rosenheim DIN 67507 and European Standard EN 673 for SEVASA glass: SatenGlas®, SatenLux® and LuxMat® (different thicknesses and types of Measurement following norm DIN 67507 vertical light transmittance.
Open the catalog to page 1SATENGLAS® TECHNICAL INFORMATION The SatenGlas® is produced on float glass according to Spanish UNE-EN 572-2. The “ift Rosenheim” was charged by SEVASA to determine the physical parameters of our glass. The measurements and evaluations are based on the German standard DIN 67507 and on the European Standard EN 673. Incidence of light on satin-finished Incidence of light on side without satin-finish Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi...
Open the catalog to page 2Incidence of light on satin-finished Incidence of light on side without satin-finish Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi Total solar energy transmittance g Measurement and calculation results for the glass pane “SatenGlas® Extraclear 5 mm” according to DIN 67507 for normal incidence of light. Spectral direct transmittance and reflectance for the glass pane “SatenGlas® Extraclear 5 mm” for normal incidence of light on side with satin-fi
Open the catalog to page 3SatenGlas® Clear 5 mm two faces Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi Total solar energy transmittance g Measurement and calculation results for the glass pane “SatenGlas® Clear 5 mm two faces” according to DIN 67507 for normal incidence of light. Spectral direct transmittance and reflectance for the glass pane “SatenGlas® Clear 5 mm two faces” for normal incidence of light on side with satin-fi
Open the catalog to page 4SatenGlas® Clear 6 mm Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi Total solar energy transmittance g Incidence of light on satin- Incidence of light on finished side without satin-finish 0,52 0,85 0,09 0,76 0,08 0,04 0,80 Measurement and calculation results for the glass pane “SatenGlas® Clear 6 mm” according to DIN 67507 for normal incidence of light. Spectral direct transmittance and reflectance for the glass pane “SatenGlas® Clear 6 mm”...
Open the catalog to page 5Incidence of light on satin-finished Incidence of light on side without satin-finish Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi Total solar energy transmittance g Measurement and calculation results for the glass pane “SatenGlas® Clear 10 mm” according to DIN 67507 for normal incidence of light. Spectral direct transmittance and reflectance for the glass pane “SatenGlas® Clear 10 mm” for normal incidence of light on side with satin-fi
Open the catalog to page 6SATENLUX® TECHNICAL INFORMATION The SatenLux® is produced on float glass according to Spanish UNE-EN 572-2. The “ift Rosenheim” was charged by SEVASA to determine the physical parameters of our glass. The measurements and evaluations are based on the German standard DIN 67507 and on the European Standard EN 673. Incidence of light on satin-finished Incidence of light on side without satin-finish Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi...
Open the catalog to page 7LUXMAT® TECHNICAL INFORMATION The LuxMat® is produced on float glass according to Spanish UNE-EN 572-2. The “ift Rosenheim” was charged by SEVASA to determine the physical parameters of our glass. The measurements and evaluations are based on the German standard DIN 67507 and on the European Standard EN 673. Incidence of light on satin-finished Incidence of light on side without satin-finish Ultraviolet transmittance τ UV Light transmittance τ Light reflectance (exterior) ρ Solar direct transmittance τe Solar direct reflectance (exterior) ρe Secondary internal heat transfer factor qi Total...
Open the catalog to page 8All SEVASA catalogs and technical brochures
-
Non-slip floor glass
6 Pages
-
SLIP RESISTANCE
7 Pages
-
Spot Resistance Test
1 Pages
-
Surface Hardness
1 Pages
-
LuxRaff® Antiscratch
2 Pages
-
HPT
2 Pages
-
HPT-TEC
2 Pages
-
LuxMat® Laquée
4 Pages
-
General Catalogue
17 Pages
-
SatenDecor
4 Pages
-
Antiscratch
6 Pages
-
Satin
4 Pages