Precontraint 1002 S2

Precontraint 1002 S2

Precontraint 1002 S2

Product catalog summary
Technical Specifications:
- Surface Treatment: S2 PVDF on both sides.
- Yarn: PES HT 1100 Dtex.
- Weight: 1050 g/sqm (31 oz/sqyd) as per EN ISO 2286-2.
- Width: 267 cm (105.1 in) with a tolerance of +1mm/-1mm.
- Tensile Strength: 420/400 daN/5cm (warp/weft) according to EN ISO 1421 and ASTM D 751-00 Cut Strip.
- Tear Resistance: 55/50 daN (warp/weft) as per DIN 53.363 and ASTM D 751-00 Trapezoid.
- Adhesion: 12 daN/5cm as per EN ISO 2411.
- Flame Retardancy: Euroclass B-s2,d0/EN 13501-1, with various ratings including M2/NFP 92-507 and B1/DIN 4102-1.

Management Systems:
- Quality: ISO 9001 compliant.
- Environmental Communication: ISO 14021 compliant.

Environmental Impact:
- LEED Heat Island Effect: Solar Reflectance Index (SRI) >95%.
- Life Cycle Assessment (LCA): Global warming potential and energy/water consumption metrics provided for different end-of-life scenarios.

Dimensional Stability:
- Elongation: Less than 1% for both warp and weft after 24 hours under 10daN/5cm load.
- Residual Elongation: Less than 0.4% as per EN 15977.

Solar Optical Values:
- Solar Transmittance: 6%.
- Solar Reflectance: 78% to 81%.
- Solar Factor: 9.5% to 12%.
- Visible Light Transmittance: 4%.
- Visible Light Reflectance: 90%.
- UV Transmission: 0%.

Thermal and Acoustic Performance:
- Thermal Conductivity: Approximately U=5.6/6.4 W/sqm/°C.
- Acoustic Weakening Index: Approximately 14dBA as per ISO 717-1.

Additional Information:
- Total Thickness: 0.78 mm.
- Coating Thickness: 200 microns at the top of the yarns.
- Varnish Adhesion Longevity: QUV A 4000 h pass Scotch tape test.

Warranty and Responsibility:
- Warranty details are case-specific and do not apply to mobile structures.
- Buyers are responsible for product application, transformation, and compliance with local standards and safety rules.

Contact Information:
- Headquarters: +33 (0)4 74 97 41 33
- Local Representative: Available on the Serge Ferrari website.

Recycling and Sustainability:
- Serge Ferrari offers an operational recycling chain and promotes the use of secondary raw materials to combat natural resource depletion.
See more

Catalog excerpts

Precontraint 1002 S2-2

> The technical data here above are average values with a +/-5% tolerance. Visible light Transmittance (Tv) -- 4 % Visible light Reflectance (Rv) -- 90 % Thermal and Acoustic performances Thermal conductivity (vertical/horizontal) ca. U=5.6 / 6.4 W/sqm/°C Calculated Acoustic Weakening index ca. 14dBA ISO 717-1 LEED Heat island Effect Solar Reflectance Index SRI >95% SSc 7.2/SSc 7.1(Roof/Non Roof] Environmental Impact: LCA (Life Cycle Assessment) Depending on end-of-life scenarios Texyloop® Recycling Incineration Global warming Energy consumption Water consumption Management...

 Open the catalog to page 2

All Serge Ferrari ARCHITECTURE catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.