video corpo

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK
14Pages

{{requestButtons}}

Catalog excerpts

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 1

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK MANUFACTURING PROCESS Regarding the daily use and/or the dimensions of the doors, they have strengthening. The profiles with a total thickness of 54.5mm have, at minimum 3 chambers (2 intermediate separations), that ensure profiles offer sufficient support and rigidity. The visible wires that are exposed to potential impacts have a minimum thickness of 2.2mm. The assemblies of the fixed frame and the opening angles have at minimum 5 corners cleats: - 2 corner cleats (inside and outside) in the central chamber - 2 corner cleats in each lateral chamber - 1 corner cleats for the strengthening of the rebate overlap Hinges must be appropriate to this type of door (see the hardware heading) Profiles are mitre-joint assembled. Aluminium alloy corner cleats are inserted into the tubing. The manufacturer can choose to fix corner cleats by crimping, cottering or using studs. Whatever the system, open ends must be tightened automatically. Corner cleats are either glued into position with a two-component epoxy adhesive then sealed with a liquid mastic containing acrylic polymers (such as Microgutta or Smalljoint) or bonded into place using a category 1 elastomer polyurethane mastic (such as Ordoflex 42). APPEARANCE On the outside and the inside, door surfaces must be flat and the fixed frame and opening aligned. As for glazing bead, the architect will appreciate a choice of different styles, such as moulded, rounded or simply straight at a sharp angle. Maximum dimensions of peripheral aluminium: - 149mm around outer edges - 178mm for the central overlap o a door with two leaves. FITTING Elements will be fitted in compliance with the architect’s plans, either: Construction: by fitting special profiles to the fixed frame that adapt it to the thickness of the insulation (jambs and upper cross rail) and adding cover strips on the inside (selection of dimensions and styles); Renovation: by incorporating jacks into the fixed frame to facilitate fitting and adjusting; external cladding on request; cover strips for interior finish (selection of dimensions and styles). Fixed frame and opening profiles must be tubular with sections calculated to resist stress generated by the location of the building project, the frequency of daily use and the size of the door. To ensure that profiles offer sufficient support and rigidity, they must be at least 54.5mm. Glazing of a maximum thickness of 36mm is maintained by clip-on glazing bead. The waterproof gaskets between the aluminium frame and the glazing are in EPDM (ethylene propylene diene monomer). 4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK

Open the catalog to page 1
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 3

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK SINGLE ACTION DOOR, 1 OR 2 LEAVES CERTIFICATE: CERTIFIED VIII CLASS, 1 000 000 CYCLES BY THE CETIM MAXIMUM WEIGHT PER LEAF: 160 kg SINGLE ACTION DOOR, 1 OR 2 LEAVES 4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK

Open the catalog to page 3
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 4

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK SINGLE ACTION DOOR, 1 OR 2 LEAVES For a perfect waterproofness, 2 gaskets must be fitted between the fixed frame and the opening of the door. These gaskets are compressed when the active opening is closed. Drainage slots are fitted with deflectors with anti-backflow valves. For mortise, lever and electric locks HARDWARE Hardware comprises flush hinges with two or three arms bearing a maximum weight of 160kg per leaf (with three hinges). Hinges are aluminium with a stainless steel axis and adjustable in three dimensions. They are...

Open the catalog to page 4
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 5

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK SINGLE ACTION DOOR, 1 OR 2 LEAVES VERTICAL CROSS-SECTION FOR PANIC LOCKS Actioned by aluminium pushbars. Colour of the bars: …………… Option: From the outside, actioned by a special lever-handle with integrated halfcylinder. Colour of the lever-handle: ………. FINISH The look the architect is aiming for calls for the following finished effect: - 20-micron anodisation, backed up by QUALANOD and EWAA-EURAS labels. Colour: …….. - LAcquering backed up by the QUALICOAT and QUALIMARINE labels. RAL shade: ……. NEW CONSTRUCTION 2 LEAVES...

Open the catalog to page 5
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 6

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK SINGLE ACTION DOOR, 1 OR 2 LEAVES RENOVATION Cross-section scale: 1/3 VERTICAL CROSS-SECTION CROSS RAILS (CREATION AND RENOVATION) DIFFERENT TYPES OF COVER STRIP (CREATION AND RENOVATION) HORIZONTAL CROSS-SECTION

Open the catalog to page 6
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 7

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK MAXIMUM WEIGHT PER LEAF: 160 kg DOUBLE ACTION, 1 OR 2 LEAVES 4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK DOUBLE ACTION, 1 OR 2 LEAVES

Open the catalog to page 7
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 8

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK DOUBLE ACTION, 1 OR 2 LEAVES WATERPROOFNESS - SECURITY For a perfect waterproofness, 2 brush gaskets must be fitted between the fixed frame and the opening of the door. Drainage slots are fitted with deflectors with anti-backflow valves. HARDWARE Hardware comprises swivels that are fixed to the rebate of the upper cross rail between the fixed frame and the opening. It also comprises an arm that covers a squared brake swivel which is embedded in the ground, under the lower cross rail of the opening. LOCKING SYSTEM ON THE ACTIVE LEAF...

Open the catalog to page 8
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 9

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK DOUBLE ACTION, 1 OR 2 LEAVES NEW CONSTRUCTION 2 LEAVES Cross-section scale: 1/3 VERTICAL CROSS-SECTION CROSS RAILS (CREATION AND RENOVATION) HORIZONTAL CROSS-SECTION

Open the catalog to page 9
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 10

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK DOUBLE ACTION, 1 OR 2 LEAVES RENOVATION 1 LEAF Cross-section scale: 1/3 VERTICAL CROSS-SECTION DIFFERENT TYPES OF COVER STRIP (CREATION AND RENOVATION) CROSS RAILS (CREATION AND RENOVATION) HORIZONTAL CROSS-SECTION

Open the catalog to page 10
4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK - 11

4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK MAXIMUM WEIGHT PER LEAF: 160 kg DOUBLE ACTION, 1 OR 2 LEAVES, WITH FINGER SAFE 4500 HEAVY DUTY SERIES ENTRANCE DOOR WITHOUT THERMAL BREAK DOUBLE ACTION, 1 OR 2 LEAVES, WITH FINGER SAFE

Open the catalog to page 11

All Sepalumic catalogs and technical brochures

Archived catalogs