The document presents photometric data for lighting fixtures characterized by angular light intensity distributions. Two main distribution types are indicated: C0-C180 and C90-C270, representing vertical planes at 0°-180° and 90°-270°, respectively.
The light intensity is measured at various angles from 0° (directly below the fixture) to 90° (horizontal), with increments at 15°, 30°, 45°, 60°, and 75°. The data is symmetrical on both sides of the 0° axis, covering negative and positive angles.
The intensity values are given in candela per kilolumen (cd/klm), with reference points at 200, 300, 400, 500, and 600 cd/klm. These values indicate the luminous intensity emitted in each direction, useful for understanding the fixture's light distribution pattern.
This photometric information is critical for lighting design, allowing engineers and designers to predict how light will be distributed in a space. The symmetrical distribution suggests uniformity in light spread along the specified planes, which can influence fixture placement and orientation for optimal illumination.
Elo Pure pole top SX 986100-9 pole top luminaire asymmetric street LED, 1200 Im, 2200 K, CRI > 70, electronic converter, Total power: 16 W for spigot 0 76mm, luminaire housing made of die-cast aluminium, powder-coated, cylinder made of PC, clear, UV-resistant. Optical system: Tritec Sky silver single, combined lens- and incl. 6m feed cable, CE, IK10, IP66, Protection Class II,optional I colour: Selux Graphite or special finish Height H: 420 mm Diameter 0: 160 mm Weight: 3,6 kg Windpressure: 0,059 m2 Make: Selux, Type: SX 986 100-9 Modifications are possible due to the constant development and improvement of LED technology. © Selux AG, Subject to technical modification 3.2025 Selux GmbH, Volkmarstr. 18, 12099 Berlin, T +49 30 72001-0, F -100, [email protected], www.selux.com
Open the catalog to page 1Technics Photometric data: 8700 Upward light ratio (ULR): 0.9 % LED 12001m, 16W, 2200 K, CRI > 70Optic Tritec Sky silver, combined lens- and reflector-optics • asymmetric street Luminous flux characteristics / Operating time of LED Operating time LED Lumen maintenance LLMF* * = Lamp lumen maintenance factor Electrics electronic converter ■ Total power: 16W ■ 6m feed cable control options: dynamic ■ DALI ■ fix value • CLT ■ HNS • AmpDim ■ individual power reduction in 300 lumen steps ex work ■ Modifications are possible due to the constant development and improvement of LED technology. © Selux...