www.seltron.eu September
Open the catalog to page 1WHY SELTRON? SELTRON is a modern technological company combining state-of-the-art technology and a wealth of experience. It provides innovative, advanced and economical heating control solutions renowned not only in Slovenia, but also throughout Europe. The company continuously invests into the development and updates its own control technology production in order to reduce energy consumption and this the savings of users as well as for the purposes of environmental protection. Ever since 1992, the company has been a partner of and a specialised OEM provider for various heating technology manufacturers...
Open the catalog to page 2Table of Contents DIFFERENTIAL CONTROLLERS Differential controllers SGC ZONE CONTROLLERS Zone controllers ZCE COMPACT WEATHER COMPENSATED CONTROLLERS Compact weather compensated controller AHD Compact weather compensated controller AHC Compact weather compensated controller CMP WEATHER COMPENSATED AND BOILER CONTROLLERS Weather compensated controllers WDC Weather compensated controllers WXD Weather compensated and boiler controllers KXD COMPACT CONSTANT TEMPERATURE CONTROLLERS Compact constant temperature controllers ACD Compact constant temperature controllers ACC CONSTANT TEMPERATURE CONTROLLERS...
Open the catalog to page 3Seltron d.o.o. | Tržaška cesta 85 A | SI-2000 Maribor | +386 (0)2 671 96 00 | [email protected] | www.seltron.eu
Open the catalog to page 4Differential controllers SGC16H | SGC26H | SGC36HV | SGC67HV They feature domestic hot water heating control, storage tank loading and energy source management such as: solid fuel boilers, pellet, oil or gas boilers, heat pumps or electric heaters.
Open the catalog to page 5Differential controllers SGC Introduction SGC universal differential controllers are intended for the control of solar systems for domestic hot water heating as well as a support system for room heating. Advanced operation algorithms ensure an optimal usage of solar energy and provide the control of energy efficient circulation pumps. The SGC controllers have integrated preset hydraulic schemes that provide a fast and simple installation. Typical application - In domestic hot water heating systems with flat or vacuum collectors. - In domestic hot water heating systems with auxiliary heat sources....
Open the catalog to page 6Start-up wizard The SGC controller is equipped with a start-up wizard, which takes you through the initial setup of the controller in 2 steps. Step 1: language selection. Step 2: hydraulic scheme selection. Step 1 When the solar system is also used for domestic hot water heating, we want to know how much heating energy has been obtained from the solar system. 1 2 3 4 5 6 7 8 9 101112 Measurement of the energy obtained The SGC controllers provide an informative and accurate measurement of the solar energy obtained and the display of the data in weekly, monthly and yearly diagrams. - For informative...
Open the catalog to page 7Typical application In domestic hot water heating systems with flat or vacuum collectors In domestic hot water heating systems with auxiliary heat sources In storage tank heating systems using a solar system and auxiliary heat sources In pool heating systems For a single-stage storage tank loading For a two-stage storage tank loading No. of preset hydraulic schemes No. of solid state relays No. of temperature sensor inputs Number of collector fields Technical characteristics Measurement of the energy obtained (kWh) Option for pulse meter flow measurement (l/min) Possibility for flow measurement...
Open the catalog to page 8Operation mode with several storage tanks Constant operation in the “OPTIMUM” mode means an optimum use of solar energy for heating all of the storage tanks taking into account the preferred storage tank The "AUTO" operation mode automatically switches between winter and summer modes according to a preset calendar Heating of all storage tanks Continuous operation in the “WINTER” mode means an alternating parallel heating of all storage tanks Constant operation in the “SUMMER” mode means the heating of only the preferred storage tank, other storage tanks are heated only when the preferred one...
Open the catalog to page 9Technical specifications Backlit graphic display Operating hours meter Weekly program timer Connection voltage Energy consumption in the standby mode Additional inputs No. of outputs 6 pcs temperature sensor (Pt 1000) 1 pc pulse input — 1 pc Triac for speed control (R2) 1 pc PWM or analogue 0÷10 V 1 pc Triac for speed control (R2) 1 pc PWM or analogue 0÷10 V (Y2) Relay outputs 1 pc Grundfos VFS flow meter 2 pcs Triac for speed control (R2, R3) 1 pc relay (R1) 2 pcs PWM or analogue 0÷10 V (Y1, Y2) Clock power supply Clock accuracy Safety class Operation mode Type of temperature sensors Housing...
Open the catalog to page 10Electrical connection
Open the catalog to page 11Solar collectors, domestic hot water storage tank. Solid fuel boiler, domestic hot water storage tank. Domestic hot water storage tank, electric heater. Solid fuel boiler, storage tank. Heating support with a storage tank. Liquid fuel boiler, domestic hot water storage tank. Heat pump, domestic hot water storage tank. Solar collectors, pool. Solar collectors, domestic hot water storage tank, auxiliary heating with electricity. Solid fuel boiler, domestic hot water storage tank, auxiliary heating with electricity. Solar collectors, domestic hot water storage tank, removal of excess heat. Domestic...
Open the catalog to page 12Solar collectors, domestic hot water storage tank, solid fuel boiler. Solar collectors, domestic hot water storage tank, liquid fuel boiler. Solar collectors, domestic hot water storage tank, heat pump. Solar collectors, domestic hot water storage tank, solid fuel boiler, auxiliary heating with electricity. Solar collectors, domestic hot water storage tank, storage tank, switchover, solid fuel boiler. Solar collectors, two domestic hot water storage tanks, switchover, electric heater. Solar collectors, two domestic hot water storage tanks, two pumps. Solar collectors, domestic hot water storage...
Open the catalog to page 13Reversible heat transfer between the main and auxiliary storage tank, two pumps. Solar collectors, three domestic hot water storage tanks, three pumps. Solar collectors, three domestic hot water storage tanks, switchover. Reversible heat transfer between the main and auxiliary storage tank, switchover. Solar collectors east-west, two pumps, two domestic hot water heaters, switchover. Solar collectors east-west, domestic hot water storage tank, two pumps. Solid fuel boiler, storage tank, domestic hot water storage tank. Pellet boiler, storage tank, domestic hot water storage tank. Solid fuel boiler,...
Open the catalog to page 14150 Pages
150 Pages
4 Pages
188 Pages
12 Pages
36 Pages
108 Pages
114 Pages
92 Pages