1. Catalogs
  2. SCHNEIDER ELECTRIC
  3. Zelio time-Timing relays catalog

Zelio time-Timing relays catalog

Zelio time-Timing relays catalog
1 / 28 PagesView full catalog

Zelio time-Timing relays catalog

Product catalog summary
Overview: The document is a catalog for Zelio Time timing relays, providing guidance on selection, specifications, and applications of various models. It includes descriptions of relay types, functions, and technical specifications.
Presentation: Timing relays are used in industrial automation to control events by opening or closing contacts at specific times. They are available in DIN rail-mounted and panel-mounted types, with applications in automatic doors, alarms, and lighting systems.
Definitions: Key terms include relay output (providing isolation between supply and output), solid state output (electronic with no moving parts), breaking capacity (current a contact can break), and mechanical durability (number of operating cycles).
Functions: Timing functions are identified by letters, such as A (Power-on delay), B (Interval relay), and C (Off-delay relay). Complementary functions enhance main timing functions, providing flexibility in automation processes.
Selection Guide: Selection criteria include functions, supply voltage, timing range, type of output, and rated current. A detailed selection table lists various models, their functions, timing ranges, supply voltages, output types, and rated currents.
Technical Specifications: The catalog details different relay types, including modular, industrial, plug-in, and panel-mounted relays, with specific time ranges and relay types like RE17Lppp, RE9, and RE48Appp.
Applications: Timing relays are used to set up simple automation cycles and complement PLC functions, reducing wiring and providing isolation between circuits.
Specifications: The relays operate on voltages from 24V to 240V and offer timing ranges from 0.1 seconds to 300 hours. They are designed with screw terminals and provide state indication via LED. Functions include delay on energization, interval timing, and asymmetrical flashing.
Functions: The document outlines several functions of the relays, including:
  • Function A: Power on delay relay, where the timing period begins on energization and the output closes after the timing period.
  • Function Ac: On-delay and off-delay relay with control signal, allowing timing to be interrupted by a gate control contact.
  • Function Ad: Pulse delayed relay with control signal, where the output closes at the end of the timing period.
  • Function Ak: Asymmetrical On-delay and Off-delay with external control, involving two timing periods Ta and Tr.
  • Function B: Interval relay with control signal, where the output closes for the duration of the timing period.
  • Function D: Symmetrical flasher relay, involving repetitive cycles with two timing periods of equal duration.
Relay Types: Relays are categorized into modular relays with solid-state output and relay output, each offering different functions and timing ranges. Solid-state output relays have a current rating of 0.7 A, while relay output relays have a current rating of 8 A.
Applications: These relays are suitable for applications requiring precise timing control, such as star-delta starters, interval timing, and pulse generation. They are used in various industrial automation processes to ensure accurate timing and control.
Key Features: The relays are multivoltage, have multi-range timing capabilities, and offer options for single or dual functions. They are equipped with a transparent, hinged, and sealable flap on the front panel for easy access and protection.
See more

Catalog excerpts

Zelio time-Timing relays catalog-1

Zelio Time Timing relays

 Open the catalog to page 1
Zelio time-Timing relays catalog-3

Zelio Time - timing relays Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 bb Presentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 bb Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 bb Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 bb Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
Zelio time-Timing relays catalog-4

Selection guide Zelio Time - timing relays These timing relays enable simple automation cycles to be set up using wired logic. They can also be used to complement the functions of PLCs. Solid state Timing relays with solid state output reduce the amount of wiring required (wired in series). The durability of these timing relays is independent of the number of operating cycles. Relay Relay outputs provide complete isolation between the supply circuit and the output. It is possible to have several output circuits. Time ranges v 1 or 2 ranges depending on model: 10 s, 30 s, 300 s, 60 min Depending...

 Open the catalog to page 4
Zelio time-Timing relays catalog-5

These timing relays enable simple automation cycles to be set up using wired logic. They can also be used to complement the functions of PLCs. Relay Relay outputs provide complete isolation between the supply circuit and the output. It is possible to have several output circuits. Panel mounted Universal v 1 range depending on model: 0.5 s, 3 s, 10 s, 30 s, 300 s, 30 min Depending on model: v 7 ranges: 99.99 s, 999.99 s, 99 min 59 s, 99.99 min, 999.9 min, 99 h 59 min, 999.9 h. v 11 ranges: 99.99 s, 999.99 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h, 999.9 h, 9999 h...

 Open the catalog to page 5
Zelio time-Timing relays catalog-6

Zelio Time - timing relays DIN rail mounted relays A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts before, during or after a set timing period. There are two main 'families' of timing relays: b "DIN rail mounted" relays (RE7, RE8, RE9, RE17, REXL…) designed for mounting on DIN rails in an enclosure, b "Panel mounted" relays type RE48A designed for mounting on the front of a panel to give users easy access to the settings. RE17 Panel mounted relays These relays have one, two or four outputs. Sometimes the second output...

 Open the catalog to page 6
Zelio time-Timing relays catalog-7

Presentation (continued) Zelio Time - timing relays Definitions (continued) Functions Timing functions are identified by letters. Main timing functions Complementary Definitions functions (1) Power on delay relay Ac On-delay and off-delay relay with control signal Pulse delayed relay with control signal Pulse delayed relay (single cycle) with control signal Asymmetrical On-delay and Off-delay with external control Power on delay relay (summation) with control signal Off-delay on energization or on opening of control contact Interval relay with control signal Bw Double interval relay with control...

 Open the catalog to page 7
Zelio time-Timing relays catalog-8

Zelio Time - timing relays Selection table Selection criteria b Functions (On-delay or Off-delay, counter, flashing…) b Supply voltage (example: a/c 12 V…240 V). b Timing range for a timing relay (example: 0.05 s…100 h) b Type of output (contact or solid state) and required Number of contacts. b Breaking capacity or Rated current of contacts, expressed in Amperes. This is the maximum current which may flow through the contacts. Functions Timing range Supply voltage Rated current 1 solid state output 1 solid state output 1 solid state output

 Open the catalog to page 8
Zelio time-Timing relays catalog-9

Zelio Time - timing relays Selection (continued) Selection table (continued) Functions Timing range Supply voltage Rated current 1 solid state output 1 solid state output 1 solid state output

 Open the catalog to page 9
Zelio time-Timing relays catalog-10

Zelio Time - timing relays U: Supply R: Relay or solid state output R1/R2: 2 timed outputs R2 inst.: The second output is instantaneous if the right position is selected T: Timing period C: Control contact G: Gate Ta: Adjustable On-delay Tr: Adjustable Off-delay Function diagram : Relay de-energized Relay energized Output open Output closed Function A: Power on delay relay 1 output The timing period T begins on energization. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. T 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output...

 Open the catalog to page 10
Zelio time-Timing relays catalog-11

Functions (continued) Zelio Time - timing relays Functions (continued) Function Ak: Asymmetrical On-delay and Off-delay with external control After power-up and closing of the control contact C, timing starts for a period Ta (timing can be interrupted by operating the Gate control contact G). At the end of this timing period Ta, the output R closes. Opening of control contact C causes a second timing period Tr to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period Tr, the output R reverts to its initial state. Ta = t1 + t2 + … Tr = t’1 +...

 Open the catalog to page 11
Zelio time-Timing relays catalog-12

Zelio Time - timing relays Functions (continued) Functions (continued) Function C:Off-delay relay with control signal 1 output After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). Function D: Symmetrical flasher relay (starting pulse off) 1 output Repetitive cycle with two timing periods T of equal duration,...

 Open the catalog to page 12
Zelio time-Timing relays catalog-13

Functions (continued) Zelio Time - timing relays Functions (continued) Function He: Pulse-on de-energization On de-energization, the output R closes for the duration of a timing period T. Function Ht: Interval relay (summation) with control signal On energization, the output R closes for the duration of a timing period T then reverts Pulsing or maintaining control contact C will again close the output R. Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a timed +t2+ ... . The relay memorises the total, cumulative opening...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.