  3. RL series load break switch/sectionaliser with ADVC controller

RL series load break switch/sectionaliser with ADVC controller

RL series load break switch/sectionaliser with ADVC controller
1 / 28 PagesView full catalog

RL series load break switch/sectionaliser with ADVC controller

Product catalog summary
Applications
The U-Series Automatic Circuit Recloser (ACR) is designed for smart grid integration, featuring loop automation and Automatic ChangeOver (ACO) to ensure continuous power supply and minimize outages. It can also function as a sectionaliser to improve feeder reliability by isolating faulty sections automatically.
Introduction and Features
The U&W-Series reclosers are cost-effective solutions with integrated Remote Terminal Units (RTUs) and communication ports, reducing installation and operating costs. They are compatible with Distribution System Automation (DSA) and SCADA systems, allowing remote control and monitoring, which enhances system integrity and customer satisfaction.
U-Series ACR Overview
The U-Series circuit breaker, controlled by the ADVC Controller, features a stainless steel enclosure and uses vacuum interrupters in epoxy bushings. It requires an auxiliary voltage supply and offers options for mounting brackets and cable connectors. The ADVC provides protection, measurement, control, and communication functions.
U-Series Recloser Specifications
The U-Series reclosers are available in 15 kV and 27 kV models, with a rated continuous current of 630 A and a fault make capacity of 12.5 kA. They are designed for a wide range of environmental conditions and have a mechanical operation life of 10,000 cycles.
W-Series ACR Overview
Similar to the U-Series, the W-Series circuit breaker is controlled by the ADVC Controller and features a vacuum interrupter in an epoxy bushing. It is enclosed in a stainless steel tank and requires an auxiliary voltage supply. The ADVC interfaces with the switchgear for remote control and monitoring.
W-Series Recloser Specifications
The W-Series reclosers have a rated maximum voltage of 24 kV and a continuous current of 400 A. They are designed for mechanical operations up to 10,000 cycles and can withstand various environmental conditions.
ADVC Controller Series
The ADVC Controller provides advanced protection, measurement, and communication features, enhancing the functionality of both U-Series and W-Series reclosers. It supports remote monitoring and control, contributing to efficient network management.
Overview
The document provides detailed technical specifications and features of the U&W-Series ADVC controller series, specifically the ADVC COMPACT and ADVC ULTRA models. These controllers are designed for outdoor pole-mounted operation, offering advanced protection, data logging, and communication capabilities.
Specifications
The ADVC controllers are housed in stainless steel enclosures (304 for COMPACT and 316 for ULTRA) to minimize temperature rise and protect internal components. They incorporate functions of a multi-function protection relay, circuit breaker controller, metering unit, and remote terminal unit. The ULTRA model offers a wider operating temperature range with an optional battery heater.
Power Supply and Efficiency
The controllers feature a microprocessor-controlled power supply ensuring uninterrupted operation. They are designed for high efficiency, allowing a battery hold-up time of up to 44 hours. The architecture ensures circuit breaker operation is independent of high voltage supply.
Communication Capabilities
The ADVC series supports various communication interfaces including RS232, RS485, Ethernet TCP/IP, and a V23 FSK modem. These interfaces facilitate integration with SCADA systems and support protocols like DNP3 and IEC 60870-5-101.
Operator Interfaces
Two operator interfaces are available: setVUE and flexVUE. The setVUE interface offers a menu-driven system with a large LCD display, while the flexVUE interface provides customizable status lamps and quick action keys for frequently used operations.
WSOS Software
WSOS version 5 is a software package for programming, monitoring, and controlling reclosers. It supports local and remote control, configuration of protection and communication parameters, and access to measurement data.
Protection Features
The ADVC controllers offer a range of protection features including inverse time curves, instantaneous protection, definite time protection, and sensitive earth fault protection. They support multiple protection groups and automatic protection group selection based on power flow direction.
Advanced Protection Features
Additional features include directional blocking, directional protection, and monitoring of sequence components. These features enhance the reliability and flexibility of the protection system.
Negative Phase Sequence Current Protection
This feature detects low-level phase-to-phase faults amidst high-level three-phase loads. It offers Inverse Time, Definite Time, and Instantaneous operation with a setting current range of 10 - 1260 A.
Sequence Coordination
Allows a recloser to coordinate its trip sequence with another downstream recloser.
Under/Over Frequency Protection
Trips the recloser when system frequency exceeds set thresholds (45 - 65 Hz). Frequency is calculated once per cycle over two cycles, with tripping occurring after 2 - 1000 cycles, and an accuracy of ± 0.05 Hz.
Under/Over Voltage Protection
Operates within defined thresholds above and below specified voltage. Under voltage threshold: 50% - 88%, Over voltage threshold: 112% - 150%, with trip delay range of 0 - 60 seconds. Phase logic options include AND, OR, and AVERAGE.
Measurement Features
True RMS voltage and current are measured, with optional external Capacitive Voltage Transformers (CVTs) for additional measurements. Real power is calculated with an accuracy of ± 5%.
Power and Power Factor
The ADVC controller measures kW, kVA, kVAr, and power factor per phase, with historical measurements recorded over intervals of 5, 15, 30, or 60 minutes.
Event History and Power Quality Toolkit
Stores up to 30,000 events. Includes supply outage measurement and harmonic analysis (harmonics 2 to 16 and THD). Waveform capture is available with user-defined triggers.
Mounting and Connection Options
Details on pole mounting, cable connection options, and optional accessories like surge arresters and CVTs are provided.
Ordering Details
Specifications for U-Series and W-Series reclosers, including circuit breaker ratings, mounting arrangements, and accessory options. Special notes highlight potential additional costs and configuration details.
ADVC Controller Options
Includes model options (COMPACT, ULTRA), operator interfaces, ambient temperature ranges, auxiliary supply types, and standard protocols. Accessories and special notes are also detailed.
See more

Catalog excerpts

RL series load break switch/sectionaliser with ADVC controller-1

Medium Voltage Distribution U-Series three-phase recloser/ W-Series single-phase recloser with ADVC controller

 Open the catalog to page 1
RL series load break switch/sectionaliser with ADVC controller-3

U-Series recloser specifications 5 W-Series recloser specifications 7 ADVC controller series 8 ADVC block diagram 9 flexVUE Operator Interface 11 General protection features 14 Advanced protection features 16 U-Series recloser - Pole mounting details 18 Required details for order 19 W-Series recloser - Pole mounting details 20 Required details for order 21 W-Series SWER recloser (W27) Required details for order ADVC controller 22

 Open the catalog to page 3
RL series load break switch/sectionaliser with ADVC controller-4

Smart grid ready With the increasing push for advanced monitoring, reduction of outages and the need to facilitate two-way communications between supply and the distribution network, the U-Series Automatic Circuit Recloser is ready to be integrated into your Smart Grid solution. Loop automation Restoring supply to your customers in the shortest possible time is the focus of recloser solutions’ loop automation scheme. The loop automation scheme recongures protection settings, sectionalises faults, minimises affected areas, and restores network supply without the need for communications or operator...

 Open the catalog to page 4
RL series load break switch/sectionaliser with ADVC controller-5

The U-Series & W-Series solid dielectric Automatic Circuit Recloser (ACR) represents Schneider Electric’s commitment to improved products and ongoing product development. Providing the features of a traditional recloser, plus the benets of up-to-date design optimised for automation, remote control and monitoring, now or in the future. The U-Series & W-Series development was driven by customer demand for improved return on capital investment in the distribution network. After careful evaluation of customers’ needs, the U-Series was developed to achieve optimum performance and reliability, making...

 Open the catalog to page 5
RL series load break switch/sectionaliser with ADVC controller-6

The U-Series ACR uses vacuum interrupters, contained in epoxy bushings, eliminating the need for insulants like oil and gas. The U-Series circuit breaker is controlled and monitored by either the COMPACT or ULTRA ADVC Controller (ADVC). The mechanism is enclosed in a 316 stainless steel tank with a stainless steel lid. Enclosed in a 304 (COMPACT) or 316 (ULTRA) grade stainless steel enclosure, the ADVC provides an electronic controller with Operator Interface (O.I.) that monitors the circuit breaker and provides protection, measurement, control and communication functions. Connected via a control...

 Open the catalog to page 6
RL series load break switch/sectionaliser with ADVC controller-7

U-Series recloser specifications Ratings Rated maximum voltage Rated continuous current Fault make capacity (RMS) Fault make capacity (Peak) Power operating time (Close / Open) Mechanical operations Rated full load operations Short time current Breaking capacity Mainly active (0.7 pf) Fault break capacity Cable charging Transformer magnetising Across interrupter Across interrupter Circuit breaker with pole mount bracket Control cubicle with control cable Gross weight of crate External VT (N-Series only) Lightning impulse withstand level Power frequency withstand voltage Service conditions Crate...

 Open the catalog to page 7
RL series load break switch/sectionaliser with ADVC controller-8

The W-Series ACR uses a vacuum interrupter, contained in an epoxy bushing, eliminating the need for insulants like oil and gas. The W-Series circuit breaker is controlled and monitored by either the COMPACT or ULTRA ADVC Controller (ADVC). The mechanism is enclosed in a 316 stainless steel tank with a stainless steel lid. Enclosed in a 304 (COMPACT) or 316 (ULTRA) grade stainless steel enclosure, the ADVC provides an electronic controller with Operator Interface (O.I.) that monitors the circuit breaker and provides protection, measurement, control and communication functions. Connected via a...

 Open the catalog to page 8
RL series load break switch/sectionaliser with ADVC controller-9

W-Series recloser specifications W-Series Ratings Rated maximum voltage Rated nominal voltage (Phase to ground) Rated continuous current Fault make capacity (RMS) Fault make capacity (Peak) Power operating time (Close / Open) Mechanical operations Rated full load operations Short time current Breaking capacity Mainly active (0.7 pf) Fault break capacity Cable charging Line charging Transformer magnetising Across interrupter Across interrupter Circuit breaker with pole mount bracket Control cubicle with control cable Gross weight of crate External VT (N-Series only) Lightning impulse withstand...

 Open the catalog to page 9
RL series load break switch/sectionaliser with ADVC controller-10

ADVC controller series Advanced protection, data logging & communications capabilities are made possible by the technology housed in the ADVC controller. With a cubicle designed to minimise temperature rise from solar heating, the 304 (COMPACT) or 316 (ULTRA) grade stainless steel enclosure is used to mount the Control And Protection Enclosure (CAPE), Power Supply Unit (PSU), customer accessories and Operator Interface. It has been designed especially for outdoor pole-mounted operation and is typically mounted low on the pole for ease of access by operation personnel. The ADVC controller series...

 Open the catalog to page 10
RL series load break switch/sectionaliser with ADVC controller-11

ADVC block diagram Switchgear Operating mechanism New and innovative features have been made possible by the intimate way the pole-mounted circuit breaker and control cubicle work together. The block diagram on this page shows how the two items are interfaced. ADVC controller Control and protection enclosure Accessory mounting tray(s) RS232 V23 Operator interface Switchgear power Communication interface Special extended range current transformers provide a range from 1 A to 12,500 A for measurement and protection. Embedded voltage screens accurately image the primary voltage value and phase relationship...

 Open the catalog to page 11
RL series load break switch/sectionaliser with ADVC controller-12

ADVC features Each recloser is provided with an Operator Interface. From here a user can access and program the many measurement and protection features available. Two different Operator Interfaces are available, these are: b setVUE Operator Interface v Based on the eld-proven operator panels in the previous controllers, this menudriven interface with large LCD display offers a familiar look and feel. setVUE Operator Interface b flexVUE Operator Interface v 20 status lamps provide a quick snapshot of the protection and controller status. v 12 quick action keys are available to execute frequently...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.