General Installation Conditions
  • Water Quality: SCHELL products are suitable for drinking water as per the Drinking Water Ordinance 2001 and meet DIN EN 50930 Section 6 requirements. Certain water types, such as sea water and chlorinated water, may pose corrosion risks.
  • Maintaining Drinking Water Quality: Proper installation and operation are crucial to maintain hygiene. Follow DIN EN 1717 or EN 806 for safety fittings and avoid water stagnation.
  • Commissioning: Flush pipes to remove dirt before commissioning. Conduct pressure tests and document instructions for system operators.
  • Installation Instructions: Only professionals should install drinking water fittings using appropriate tools. Avoid excessive force and ensure no stress is transferred to fittings.
  • Service Instructions: Regularly inspect and replace sealing elements and safety features like backflow preventers as per EN 806 Part 5.
  • Maintenance Instructions: Use mild detergents for cleaning. Avoid abrasive or chemically aggressive agents.
  • Environmental Protection: SCHELL uses recyclable materials and designs processes to conserve resources. Dispose of batteries and electronics properly.
  • Norms and Regulations: Follow all relevant norms and regulations for installation and maintenance.
Installation Norms and Regulations
Adhere to applicable installation norms and regulations, including those from electricity and water utility companies. Safety ranges for electronically controlled fittings must be observed, and external power sources and magnetic fields should not impair electronic controls. Follow SCHELL installation manuals and operating instructions to avoid scald hazards from hot water.
Hygiene Considerations
SCHELL emphasizes internal, external, and technical hygiene in product development. Internal hygiene involves using materials suitable for drinking water contact, while external hygiene focuses on easy-to-clean surfaces. Technical hygiene includes features like stagnation flushes to maintain water quality.
Drinking Water Hygiene
Maintaining high water quality is essential, especially in facilities like hospitals and schools. Key measures include managing cold and hot water temperatures and ensuring regular water exchange. Cold water should not exceed 25°C, and hot water should not drop below 55°C.
Water Quality Maintenance
Regular use of sanitary fittings is crucial to prevent bacterial growth. Intelligent stagnation programs can balance water saving and hygiene by detecting usage patterns and flushing only when necessary.
Legionella and Bacterial Risks
Legionella can pose a risk in improperly managed water systems. Maintaining appropriate water temperatures and regular water exchange can mitigate this risk. Thermal disinfection is a reactive measure for microbiological challenges.
Responsibilities and Standards
Operators of drinking water installations must ensure water safety and comply with standards like the Drinking Water Ordinance. Regular water exchange and temperature maintenance are essential. Users and tenants should be informed about the importance of regular water exchange to prevent water spoilage.
Water and Energy Saving
Efficient water use is vital, given the limited availability of fresh water. SCHELL products aim to balance water saving with maintaining water quality, especially in older installations with potential hygiene risks.
Water Consumption and Conservation
The document highlights the global water distribution challenge, emphasizing that if the available water were evenly distributed, each person would receive approximately 2,000 m³. In Germany, this would suffice for personal drinking needs for about 40 years. The uneven distribution and varying replenishment rates necessitate water and energy conservation, which also saves money and energy required for water reprocessing.
SCHELL Electronic Fittings
SCHELL's electronic fittings can save up to 40% of water compared to traditional two-handle fittings by adjusting flow times. Benefits include economic savings, ecological and hygiene advantages, and resource preservation. The fittings are adjustable for washbasins and showers, with features like frequency detection to reduce flush volume.
Water Use in Households and Small Businesses
The document provides a breakdown of water usage in various activities such as personal hygiene, toilet flushing, laundry, and dishwashing, highlighting the importance of efficient water use.
Certification and Standards
SCHELL products undergo rigorous testing and certification to meet international and country-specific standards, such as DIN DVGW, KIWA, and Belgaqua. Compliance with these standards ensures the products are suitable for drinking water installations and meet sustainability criteria.
Sustainability and Efficiency Labels
The document discusses the importance of sustainability in building construction and operation, with certifications like LEED and WELL indicating high standards in water and energy efficiency. LEED certification, in particular, is gaining significance in Germany, offering benefits like higher market value and rental income for certified buildings.
Comfort and Ergonomics
SCHELL products offer user convenience through features like contact-free water control, adjustable flushing programs, and ergonomic design. These features ensure ease of use and maintenance, contributing to economic operation and user satisfaction.
Service-Friendliness and Safety
The document emphasizes the importance of service-friendly design, with easily accessible components and mechanisms to ensure operational safety. SCHELL products incorporate features like prefilters and backflow preventers to minimize service frequency and ensure compliance with safety standards like scalding protection.
Specifications:
The document outlines various specifications for SCHELL sanitary fittings, including ceramic upper parts with thermostat cartridges that have a changeable/lockable temperature lock at 38°C and safety locking for water failure. It includes locking discs for maximum temperature limiting to prevent scalding, backflow preventers compliant with DIN EN 1717, and ergonomic arm-levers.
Technical Data:
Flow class of fittings is categorized as 'A', with flow pressure ranging from 1 to 5 bar. The maximum hot water temperature is 70°C for short-term use. The material used is brass, conforming to German drinking water regulations, and the products are Belgaqua certified.
Dimensions and Weight:
Products are available in various dimensions (DN 15 G 1/2 ext. thread) and weights, with specific reach measurements up to the middle of the aerator. Some models include integrated mechanical valves for manual thermal disinfection according to DVGW worksheet W 551.
Recommended Accessories:
Includes S-connection sets with isolating valves and eSCHELL USB sticks for parameter adjustment and diagnosis of fittings. The USB stick requires specific system software and hardware requirements.
Product Descriptions:
The document provides detailed descriptions of various SCHELL products, including self-closing wall-mounted taps, extension cartridges, and electronic shower fittings with thermostats. Each product description includes order numbers, material specifications, and recommended associated items.
Functional Features:
SCHELL thermostatic fittings are designed to automatically shut off hot water if the cold water supply fails, with a preset temperature limit of 38°C. The fittings include a release button for temperatures above 38°C.
System Requirements for eSCHELL Software:
The eSCHELL software requires Windows XP, Vista, 7, or 10, with specific display resolution, disk space, and RAM requirements. It includes an eUSB-Stick with software, an operating manual, and a driver for the eSCHELL-USB-Adapter.
See more

Catalog excerpts

Catalogue 2016 / 2017-1

Catalogue 2016 / 2017. Valve technology. By SCHELL. Electronic wash basin tap CELIS Regulating angle valve COMFORT SCHELL GmbH & Co. KG Armaturentechnologie Raiffeisenstraße 31 57462 Olpe Germany Telefon +49 2761 892-0 Telefax +49 2761 892-199 [email protected] www.schell.eu Wall-mounted shower fitting VITUS

 Open the catalog to page 1
Catalogue 2016 / 2017-2

Sanitary and Heating Fittings Plant 1 Production with administration and training centre Plant 2 Production with logistics centre Quality and Innovation. SCHELL - reliable partner for sanitary and heating - can look back over more than 80 years of experience in the design and manufacture of practical sanitary and heating fittings. High-quality basic materials and automated manufacturing processes are the foundation for quality fittings »Made by SCHELL in Germany«. Furthermore, SCHELL continuously tackles new topics and turns them into innovative products which genuinely benefit both the user...

 Open the catalog to page 2
Catalogue 2016 / 2017-3

Sanitary draw-off taps 10 Wash basin draw-off taps / Accessories 11 Concealed wall-mounted draw-off taps / Accessories 12 Exposed taps / Accessories 13 Concealed wall mounted shower fittings / Accessories 14 Exposed wall-mounted shower fittings / Accessories WC and urinal flush systems 20 Concealed WC flush valves / Accessories 28 WC operating panels and cistern mounting modules 21 Exposed WC flush valves / Accessories 22 Concealed urinal flush valves / Accessories 23 Exposed urinal flush valves Mounting modules Product information Wash basin mounting modules Mounting modules for shower / Bidet...

 Open the catalog to page 3
Catalogue 2016 / 2017-4

Order number index

 Open the catalog to page 4
Catalogue 2016 / 2017-5

Order number index

 Open the catalog to page 5
Catalogue 2016 / 2017-6

Order number index

 Open the catalog to page 6
Catalogue 2016 / 2017-7

Order number index

 Open the catalog to page 7
Catalogue 2016 / 2017-8

Order number index

 Open the catalog to page 8
Catalogue 2016 / 2017-9

Order number index

 Open the catalog to page 9
Catalogue 2016 / 2017-10

Order number index Order Group Page GTIN-Code

 Open the catalog to page 10
Catalogue 2016 / 2017-11

Order number index Order Number Group Page Group Page Order Number Group Page

 Open the catalog to page 11
Catalogue 2016 / 2017-12

SCHELL International respresentatives Director International Sales Application Specialist Export Manager for Northern and Eastern Europe Export Manager for Southern Europe, Middle East and Overseas Export Manager for Western Europe SCHELL Marketing Marketing Management Jens Gebers Advertising and Public Relations Joachim Wieczorek Head of Product Management Dr. Peter Arens SCHELL Armaturentechnologie 57462 Olpe Addresses SCHELL office Albania Besnik Beqiri Kerasan Giovanni Affronte Alexandra Zielsow-Kass Phone +49 2761 892-255 [email protected] BQT Pty. Ltd PO...

 Open the catalog to page 12
Catalogue 2016 / 2017-14

Sales organisation SCHELL office Czech Republic V Ales R ezac Palliardiho 13 Andrea Backer Czech Republic [email protected] Giovanni Affronte Phone +49 2761 892-263 [email protected] Egypt Duravit Egypt Mohamed Adel Duravit Building Janina Hof Elmosheer Ahmed Ismail St. Phone +49 2761 892-195 Sheraton, Heliopolis [email protected] Druvis Kalviskis Giovanni Affronte Phone +49 2761 892-263 [email protected] SCHELL France Michael Ruch Filiale du Goupe SCHELL GmbH & Co KG 455, Promenade des Anglais Phone +49 2761 892-398 Denis Delaunay...

 Open the catalog to page 14
Catalogue 2016 / 2017-16

Sales organisation SCHELL office Latvia Druvis Kalviskis Giovanni Affronte Phone +49 2761 892-263 [email protected] Lebanon Sami Hert & Sons United Nations Avenue Bir Hassan Janina Hof RL-Beirut / Lebanon Phone +49 2761 892-195 Lith uania Druvis Kalviskis Giovanni Affronte Phone +49 2761 892-263 [email protected] Luxembourg SCHELL Belgium BVBA/SPRL Director Dirk Vanden Breede Project Manager Michel van Boxstael Technical Assistance Pascal Marcelis / Yvan Malicheff Brusselsesteenweg 171 Michael Ruch Belgium [email protected] Macedonia Besnik Beqiri Kerasan Giovanni...

 Open the catalog to page 16
Catalogue 2016 / 2017-17

Giovanni Affronte Phone +49 2761 892-263 [email protected]

 Open the catalog to page 17
Catalogue 2016 / 2017-18

Addresses SCHELL office Saudi Arabia Specialized Suppliers DMCC Unit 1904, Jumeirah Bay Janina Hof Jumeirah Lakes Towers [email protected] Estin Hoon Wung Kiong Singapore 229318 Phone +49 2761 892-195 Slovakia Ivan Bahnik Bflikova 20 Andrea Backer Slovakia [email protected] Slovenia Endosan d.o.o. Jan Strmsek Andrea Backer Phone +49 2761 892-292 [email protected] South Africa Hansgrohe South Africa (Pty) Ltd Wilhelm Import Network (Pty) Ltd Max Guldenpfennig Giovanni Affronte Phone +49 2761 892-263 [email protected] Spain Aquacontrol ATS S.A. Angel...

 Open the catalog to page 18
Catalogue 2016 / 2017-19

Sales organisation SCHELL office Syria Specialized Suppliers DMCC Unit 1904, Jumeirah Bay Janina Hof Jumeirah Lakes Towers [email protected] Thailand Charn Paiboon Corporation Ltd. Turkey Ayca Kulac Area Sales Manager Alexandra ZieGow-Kass Phone +49 2761 892-255 [email protected] Giovanni Affronte Phone +49 2761 892-263 [email protected] United Arab Emirates Specialized Suppliers DMCC Unit 1904, Jumeirah Bay Janina Hof Jumeirah Lakes Towers [email protected] Yemen Specialized Suppliers DMCC Pierre El Dik

 Open the catalog to page 19
Catalogue 2016 / 2017-21

General installation conditions SCHELL. Responsibility for health. General installation conditions 22 - 24 Saving water and energy 31 Certificates, LEED, WELL 32 - 34 Comfort / Easy servicing 35

 Open the catalog to page 21
Catalogue 2016 / 2017-22

General Installation Conditions. From SCHELL. SCHELL fittings are designed and produced according to the technical norms and regulations valid in Germany and in Europe/internationally, as far as possible. The fittings are designed in such a way that they guarantee trouble-free operation while complying with installation regulations, professional installation, as well as proper servicing and maintenance. Water quality 1. Water quality (suitability) SCHELL products are suitable for use with drinking water according to the Drinking Water Ordinance 2001 (TrinkwV). The alloy components meet the requirements...

 Open the catalog to page 22
Catalogue 2016 / 2017-23

Installation instructions We refer to the fact that SCHELL fittings contain silicone seals and grease. For this reason, the fittings are not approved for use in lacquering/painting businesses. Service instructions 5. Service instructions Fittings and their components are subject to natural wear, like other mechanical components. Sealing elements are particularly affected, especially those that should be replaced at regular intervals on systems with a need for high operational reliability (clinics or a high degree of use (public facilities). Safety features such as backflow preventer must be inspected...