05/17 - 2 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 2Description The air diffuser type ZMD is an air diffuser for universal use in all mounting situations. Owing to its infinitely variable adjustment from long-throw to wide-angle diffusion, it is universally suited to ventilate all types of rooms, particularly high-ceiling halls, rooms with considerable heat generation, behind raster ceilings, etc. Suitable for all air-conditioning systems. Installation is possible in any ceiling construction. The ZMD diffuser head has several rows of apertures, arranged in a specific relationship. The front apertures can be completely or partially closed by a...
Open the catalog to page 3ZMD air diffuser Models and dimensions Minimum setting Air throw pattern Wide angle setting Adjusting disc Long throw setting Standard setting: maximum To reduce the flow rate, i.e., increase the pressure loss, by means of the nozzle, the diffuser head can be slid towards the rear, by loosening the slotted screws on the side, until the upper row is covered (minimum position). The volumetric flow can be determined, as shown in the pressure loss diagrams, by means of a static tube. Increase of noise due to the damping should be taken into consideration. In the long throw position, the adjusting...
Open the catalog to page 4for duct installation - K00 (with curved blade, -K01) for ceiling installation -D00 (with cover plate, -D01) Curved blade sectional view 1.) Screw mounting * Sheet metal collar Cover plate *Part 1 fitted only if delivered with sheet metal collar 1.) On-site mounting holes for installation in round ducts, -RA0 / -RB0 / -RC0 (with curved blade, -RA1 / -RB1 / -RC1) Curved blade The sheet metal collar (-BK1) is delivered loose and can be fixed to the connection spigot with a self-tapping screw during onsite assembly. The sheet metal collar (-BK1) cannot be retrofitted, as part 1 is not included in...
Open the catalog to page 5ZMD air diffuser Dimensions of accessories Jet guide (jet shielding) Guide ring. to be used for wide-angle jet only Plug for shielding columns and walls, etc. Adjusting disc Plug for shielding columns and walls, etc. (-X) Number of plugs can be freely selected (1 < x < 9) 05/17 - 6 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 6ZMD air diffuser Technical data Pressure loss and noise level ZMD-100 wide-angle setting (max.) sound power level ZMD-150 Total pressure loss ZMD-150 long throw (max.) ——— The values apply to hose connections. They decrease by approximately 4 dB for pressure duct connections. Relative difference in sound power level (RS) Hz ZMD-150 long throw max. 05/17 - 7 Construction subject to change. Version: 17.02.2020 No return poss
Open the catalog to page 7ZMD air diffuser Maximum end velocity of jet ZMD-100 wide-angle setting (max.) 05/17 - 8 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 8ZMD air diffuser Critical throw Maximum penetration ZMD-150 (heating) long throw (max.) Room height 05/17 - 9 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 9ZMD air diffuser Temperature and induction ratios ZMD-100 05/17 - 10 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 10ZMD air diffuser Further data Selection diagram: ZMD-150 wide-angle setting (max.) Relative sound power level difference Read temperature ratio TV for determining the temperature ∆Tx in the diagram. For the jet throw x + jet throw y, the value x from the diagram must be used. 05/17 - 11 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 11ZMD air diffuser Selection diagram: ZMD-150 wide-angle setting (min.) Relative sound power level difference Read temperature ratio TV for determining the temperature ∆Tx in the diagram. For the jet throw x + jet throw y, the value x from the diagram must be used. 05/17 - 12 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 12ZMD air diffuser ZMD-150 wide-angle setting (max.) Two opposite jets ZMD-150 wide-angle setting (min.) Two opposite jets 05/17 - 13 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 13ZMD air diffuser ZMD-150 wide-angle setting (max.) with wall effect Acoustic data ZMD-150 wide-angle setting (min.) with wall effect For VR, the following values must be used: sound-attenuated room = VR x 2, normal room = VR and hard room = VR x 0.5 05/17 - 14 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 14Supply air volume Room volume Maximum end velocity of jet Face area horizontal throw vertical throw Critical jet path Density Pressure loss A-weighted sound power level Temperature difference between supply air temperature and room temperature (DTO = tZU - tR) Temperature difference between air supply and room temperature in heating mode (DTOH = tZUH - tRH) Temperature difference at point x Supply air temperature Room temperature Induction ratio (i = VX / VZU) Temperature ratio (TV = DTX / DTO) Room height Nominal width Room attenuation Penetration depth in heating mode Horizontal + vertical...
Open the catalog to page 15ZMD air diffuser ZMD order code 01 All fields must be filled when ordering. Sample ZMD-100-9010-SM-D01-BK0-9010-0 Air diffuser type ZMD I Nominal width 100 I Nozzle head colour RAL 9010 (white) I With screw mounting I For ceiling installation with cover plate | Without sheet metal collar | Sheet metal parts painted to RAL colour 9010 (white) | Without shielding plug Order details 01 - Type ZMD = Air diffuser type ZMD 02 - Nominal width 100 = Nominal width 100 mm 150 = Nominal width 150 mm 03 - Nozzle head colour 9005 = RAL colour 9005 (polystyrene, black) 9010 = RAL colour 9010 (polystyrene,...
Open the catalog to page 16ZMD air diffuser Specification texts Air diffuser with high inductive effect, flame-resistant. Consisting of a plastic (polystyrene 4754) diffuser head with radially arranged apertures with integrated adjustable damper disc and connection spigot. Product: SCHAKO type ZMD-100/-150 Model: ZMD-...-D00 ZMD-...-D01 ZMD-...-K00 ZMD-...-K01 ZMD-...-RA0 ZMD-...-RA1 = for ceiling installation (without cover plate) = for ceiling installation (with cover plate) = for duct installation (only possible without cover plate) = for duct installation with curved blade (only possible without cover plate) = for...
Open the catalog to page 1732 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages