Technical documentation WGA Long throw nozzle grille SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen
Open the catalog to page 1WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Function and use I Models FUNCTION AND USE WGA-Q-F0-... WGA-Q-V0-... WGA-Q-VG-... WGA-Q-VE-... WGA-Q-VT-... WGA-R-F0-... WGA-R-V0-. WGA-R-VG-. WGA-R-VE-. WGA-R-VT-. Since multi-purpose halls have many different uses, great demands are placed on their air-conditioning and ventilation requirements. Since both sporting and cultural events are held in these halls, requirements with regard to supply of air volumes and temperature differences between supply and room temperature also change. The long throw nozzle grille type WGA has been specially...
Open the catalog to page 2WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Processing I Accessories Frame -- sheet steel (-SB), painted to: - RAL colour 9010 (-9010, white, standard) - RAL colour 9005 (-9005, black) - RAL colour 9006 (-9006, white aluminium) - RAL colour 9007 (-9007, grey aluminium) - painted to RAL of your choice (-xxxx) Nozzles -- Plastic: - similar to RAL colour 9010 (-DW, white, standard) - similar to RAL colour 9005 (-DS, black) - similar to RAL colour 9006 (-DA, white aluminium) - similar to RAL colour 9007 (-DG, grey aluminium) Electric actuator -- for WGA-Q-VE-... / WGA-R-VE-... : - 230...
Open the catalog to page 3WGA – Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I MODELS AND DIMENSIONS For installation in walls / ducts fixed nozzles WGA-Q-F0-… Screw mounting (-SM) and concealed mounting (-VM) (-VM), see page 16. Construction subject to change No return possible
Open the catalog to page 4WGA – Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I For installation in walls / ducts individually adjustable nozzles WGA-Q-V0-… Screw mounting (-SM) and concealed mounting (-VM) (-VM), see page 16. Construction subject to change No return possible
Open the catalog to page 5For installation in walls / ducts nozzles jointly manually adjustable WGA-Q-VG-... WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I All combined lengths and heights available. Special dimensions not available! Screw mounting (-SM), see page 16. For model with a plenum box (AK-38 / AK-39), the length (L) of the installation opening increases by 5 mm. Construction subject to change No return possible
Open the catalog to page 6WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I For installation in walls / ductselectric block adjustment WGA-Q-VE-... electric actuator lateral central nozzles jointly adjustable via thermocouple without electrical energy WGA-Q-VT-... Available sizes (for WGA-Q-VT-... / WGA-Q-VT-SS-... / WGA-Q-VT-BS-... / WGA-Q-VT-SS-BS-.) Available sizes (for WGA-Q-VE-... / WGA-Q-VE-SS-... / WGA-Q-VE-BS-... / WGA-Q-VE-SS-BS-...) Construction subject to change No return possible
Open the catalog to page 7WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I fixed nozzles All combined lengths and heights available. Special dimensions not available! For 0D, see installation situation page 12. Screw mounting (-SM), see page 16. Construction subject to change No return possible Version: 2019-07-04 | Page 8
Open the catalog to page 8WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I For installation in round ducts individually adjustable nozzles WGA-R-V0-... All combined lengths and heights available. Special dimensions not available! For 0D, see installation situation page 12. Screw mounting (-SM), see page 16. Construction subject to change No return possible
Open the catalog to page 9WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I Available sizes WGA-R-VG-... / WGA-R-VG-...-BS-... For installation in round ducts nozzles jointly manually adjustable All combined lengths and heights available. Special dimensions not available! For 0D, see installation situation page 12. Screw mounting (-SM), see page 16. Construction subject to change No return possible Version: 2019-07-04 | Page 10
Open the catalog to page 10WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Models and dimensions I electric actuator lateral central Available sizes (for WGA-R-VT-... / WGA-R-VT-SS-... / WGA-R-VT-BS-... / WGA-R-VT-SS-BS-...) electric actuator for WGA-R-VE-... / WGA-R-VE-SS-... / WGA-R-VE-BS-... / WGA-R-VE-SS-BS-...: Construction subject to change No return possible
Open the catalog to page 11QUICK SELECTION WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Quick selection I Installation situation WGA-R-F0-... / WGA-R-V0-... / WGA-R-VG-... / WGA-R-VE-... / WGA-R-VT-...The grilles only lie completely flush with ideal duct diameter. Duct diameter Apart from high stability and torsional rigidity, the diagonal flange and the two height dimensions allow an optimum adjustment of the long throw nozzle grilles type WGA-R-... to sheet steel or spiral ducts. The selection of the grille height depends on the duct measures shown in the table. The installation of the WGA-R-... in spiral ducts...
Open the catalog to page 12WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Band design I Installation situation Only possible for WGA-Q-F0-... and WGA-Q-V0-... Long throw nozzle grille classification valid for SM and VM mounting. Band design is also possible without a plenum box. Dimensions + prices with hit-and-miss damper upon request. 2-part if length of band BL < 2025 mm Spigot in the plenum box for end pieces without spigot: KL = <120mm or < (0D+9O) EOL = Ceiling opening dimensions 1.) = Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on site) (with SM mounting...
Open the catalog to page 13WGA - Long throw nozzle grille TECHNICAL DOCUMENTATION Dimensions of accessories I DIMENSIONS OF ACCESSORIES Plenum box (-AK) with lateral spigot (-S1), only for WGA-Q-... AK-37-...-S1: for WGA-Q-F0-... / WGA-Q-V0-... AK-38-...-S1: for WGA-Q-VG-... / WGA-Q-VT-... AK-39-...-S1: for WGA-Q-VE-... Grilles cannot be fitted with a hit-and-miss damper if a plenum box is attached, i.e., it can either be fitted with a hit-and-miss damper or a plenum box. Spigot arrangement lateral spigot, KL central (-S1, standard) spigot from above, KL central (-S0) spigot front side, KB central (-S4) KL = length of...
Open the catalog to page 1432 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages