ADDITONAL OPERATING INSTRUCTIONS ACCORDING TO ATEX 2014/34/EU VQEX Volumetric flow controller ATEX PERFORMANCE DATA Operating temperature: 10 - 50° C Ambient temperature: 0-50° C Differential pressure range: 50-1000 Pa Volumetric flow range: 291 to 47081 m³/h Housing leakage according to DIN EN 1751, class B Housing and damper leaf leakage to DIN EN 1751, up to Class 4, (only JK-LU) For regulating the air velocity in duct in the range of 2-13 m/s Command signal: 0-10 V DC or 2-10 V DC VDI 6022, Sheet 1: Hygienic requirements of ventilation and air-conditioning systems DIN EN 13779 (2007): Ventilation of non-residential buildings Leakage air: EN 1751 (2014-06) Ventilation for buildings - Aerodynamic testing of damper and valves Compact dimensions and low depth (400 mm) position-independent installation possible Low pressure loss easy mode of operation and reliable control simple commissioning and setting, without the need of additional setting devices at the controller with spring return actuator (if required) SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen RoHS 2002/95/EC 2014/34/EU ATEX (product directive) EMC 2004/108/EC Low voltage 2006/95/EC
Open the catalog to page 1
ATEX volumetric flow controller VQEX ADDITIONAL OPERATING INSTRUCTIONS ACCORDING TO ATEX 2014/34/EU Table of contents | Construction subject to change No return possible
Open the catalog to page 2
ATEX volumetric flow controller VQEX ADDITIONAL OPERATING INSTRUCTIONS ACCORDING TO ATEX 2014/34/EU Overview of product versions | Function OVERVIEW OF PRODUCT VERSIONS VQEX FUNCTION A volumetric flow controller is used for pressure-independent volumetric flow regulation in ventilation and air-conditioning systems. It serves to keep the volumetric flow either constant within specified limits (CAV) or to control it variably (VAV). The housing, measuring sensor, blades, PI controller with pressure sensor and actuator form a closed control loop with feedback, allowing demand-dependent,...
Open the catalog to page 3
ATEX volumetric flow controller VQEX ADDITIONAL OPERATING INSTRUCTIONS ACCORDING TO ATEX 2014/34/EU Areas of application | Tests and standards • with supply voltage 24 V AC / DC +/- 15 %, 50/60 Hz • with DD varnish coating for aggressive media (please refer to the resistance table in a separate documentation) • for regulating the air velocity in the duct in the range of 2...13 m/s • can also be used with vertical axis The rectangular volumetric flow controller type VQEX made of galvanised steel is suitable for use with aggressive components of polluted air and in areas subject to explosion...
Open the catalog to page 4
ATEX volumetric flow controller VQEX ADDITIONAL OPERATING INSTRUCTIONS ACCORDING TO ATEX 2014/34/EU Processing | Available sizes PROCESSING AVAILABLE SIZES Housing • Galvanised sheet steel • Galvanised sheet steel with DD coating • opposed, made of extruded aluminium profile (JK-LU) • opposed, made of sheet steel profile (HKU) Blade seal • made of PUR, silicone-free • airtight sealing design to DIN-EN 1751, up to class 4, including multi-leaf damper JK-LU • not sealing airtight, including multi-leaf damper HKU Blade support • Sintered bearing Blade activation • Stainless steel gear wheels...
Open the catalog to page 5
ATEX volumetric flow controller VQEX ADDITIONAL OPERATING INSTRUCTIONS ACCORDING TO ATEX 2014/34/EU Useable volumetric flow ranges | ► MIN value refers to air velocity of 2 m/s ► MAX value refers to air velocity of 13 m/s When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed. Other sizes available on request. ATTENTION: IMPORTANT FOR PARAMETERISATION • The table of "useable volumetric flow ranges" corresponds to the complete measuring range. • When the air volume drops below Vmin, the correct...
Open the catalog to page 6
ATEX volumetric flow controller VQEX TECHNICAL DOCUMENTATION Min i mum torque VQEX-HKU I Minimum torque VQEX-JK-LU H 600 - 1003, class 4 at 1000 Pa available at an extra charge Construction subject to change No return possible
Open the catalog to page 7
ATEX volumetric flow controller VQEX TECHNICAL DOCUMENTATION Accessories | Accessories dimensions made of sound-absorbing, insulating 40 mm material, nonflammable according to DIN 4102-17, with sheet steel covering made of galvanised sheet steel (standard), with cage nuts (M6) Mineral wool silencer (-ZSQ-EX) with baffles type MWK --- Housing of galvanised sheet steel (standard) --- Baffle frame made of galvanised sheet steel (standard), on both sides with METU profile M3 — Mineral fibre boards according to DIN 4102 A2, with glass filament cover, biosoluble, wear-resistant additional...
Open the catalog to page 8
ATEX volumetric flow controller VQEX TECHNICAL DOCUMENTATION Sound data | Construction subject to change No return possible
Open the catalog to page 9
ATEX volumetric flow controller VQEX TECHNICAL DOCUMENTATION Connection diagram ATEX unit | Connection diagram - ATEX controller CONNECTION DIAGRAM ATEX UNIT CONNECTION DIAGRAM - ATEX CONTROLLER ExReg-V300-A is the standard version for controlling variable volumetric flows (VAV). The alarm contact (terminal 3) serves to provide feedback for normal operation. Moreover, the device has an analogue output (terminal 11) which emits the current setpoint value as a continuous signal and an analogue feedback of the damper position (terminal 9). This function is mainly used for saving energy. A...
Open the catalog to page 10
ATEX volumetric flow controller VQEX TECHNICAL DOCUMENTATION Prior to mounting and commissioning | PRIOR TO MOUNTING AND COMMISSIONING An instruction leaflet containing information on safety, transport disposal, installation, commissioning and maintenance is enclosed with each SCHAKO product. For safety reasons, this instruction leaflet must be read der all circumstances and completely adhered to. Zero point adjustment of the static pressure sensor see SCHISCHEK documentation For Schischek ExReg-V300-A controller, a zero adjustment must be performed for commissioning in order to correct...
Open the catalog to page 11
ATEX volumetric flow controller VQEX TECHNICAL DOCUMENTATION Installation information | Maintenance and service To avoid unnecessary controller errors, the min. distances according to the following table / drawings must be observed. For combinations of several connection pieces or pieces with fire dampers or silencers, the larger minimum distances must be observed. All volumetric flow controllers can be assembled with horizontal or vertical damper axis. Distance to a fire damper Construction subject to change No return possible • When the device is delivered, check whether the controllers...
Open the catalog to page 12All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages