VASSound-damped volumetric flow controller PERFORMANCE DATA TESTS AND STANDARDS • Operating temperature: 10 - 40° C • Difference pressure range 50 - 1000 Pa • Connection voltage for VAS (electronic): 24V DC/AC, ±10%, 50/60 Hz • Control signal: 0-10 V DC or 2-10 V DC • VDI 6022, Sheet 1: Hygienic requirements of ventilation and air-conditioning systems • DIN EN 13779 (2007): Ventilation of non-residential buildings • Leakage air: DIN EN 1751 (2014-06) SPECIAL FEATURES APPROVALS AND CERTIFICATES • RoHS 2002/95/EC • EMC 2004/108/EC • Low voltage 2006/95/EC • Machinery Directive 2006/42/EC • Compact dimensions and low height • Integrated high-performance silencer • High precision, easy mode of operation and reliable control • Low pressure losses • No inflow or outflow distances required. SCHAKO | Ferdinand Schad KG SteigstraRe 25-27 D-78600 Kolbingen
Open the catalog to page 1VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Table of Contents Construction subject to change. No return possible.
Open the catalog to page 2VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Description | Function | Field of application The sound-damped volumetric flow controller VAS in rectangular design is suitable for use in supply or return air systems for constant and variable volumetric flows at high acoustic requirements. The VAS achieves high control accuracy at any inflow conditions. It can also be used for controlling room or duct pressure. In VAV systems, the integrated volumetric flow controller VAS can regulate variable volumetric flows between Vmin and Vmax as a function of the supply air temperature....
Open the catalog to page 3VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Advantages | Construction | Version| Product versions | Accessories OVERVIEW OF PRODUCT VERSIONS Compact dimensions and low height Integrated high-performance silencer High precision, easy mode of operation and reliable control Optimised for systems of low velocities Low pressure losses Significant savings in operating costs during installation For rectangular and round duct connections Low mounting and maintenance expenditure No inflow or outflow distances required. Figure 1: Supply air, left-hand model, top view CONSTRUCTION...
Open the catalog to page 4VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Dimensions and weights Detail Y Supply air: Return air: Duct: B = blue R = red Table 1: Weights VAS-K/ VAS-S Construction subject to change. No return possible. Version: 2017-05-08 | Page 5
Open the catalog to page 5VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Dimensions of accessories DIMENSIONS OF ACCESSORIES Transition piece (-USR) Connection to round ducts on high-pressure side for supply air or return air (to DIN EN 1506). Rubber lip seal (-GD1, for -USR only) Detail X: Metu flange Figure 6 : Rubber lip seal (-GD1) Figure 7: Connection to round ducts on high-pressure side Table 3: Connection to round ducts on high-pressure side Figure 8: Connection to rectangular ducts NW 1 2 3 4 5 Table 4: Connection to rectangular ducts Construction subject to change. No return possible. Connection...
Open the catalog to page 6VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Dimensions of accessories ■CHAK# Flat-bed acoustic cladding (-FD1) Integrated into VAS- / VAS-S housing Tabel 5: Flat-bed acoustic cladding (-FD1) Table 6: Heating register Construction subject to change. No return possible.
Open the catalog to page 7VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data Volumetric flow range Table 8: Static minimum pressure difference For correct operation of the controller, please note that an additional 5 Pa must be added to the static minimum pressure difference during parameter setting. Construction subject to change. No return possible.
Open the catalog to page 8VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 9: Flow generated noise VAS-K-Z Construction subject to change. No return possible.
Open the catalog to page 9VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 10: Flow generated noise VAS-K-A Construction subject to change. No return possible.
Open the catalog to page 10VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 11: Flow generated noise VAS-S-Z Construction subject to change. No return possible.
Open the catalog to page 11VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 12: Flow generated noise VAS-S-A Construction subject to change. No return possible.
Open the catalog to page 12VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data Table 13: Radiated noise VAS-K-Z / VAS-S-Z / VAS-K-A / VAS-S-A Construction subject to change. No return possible.
Open the catalog to page 13VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data Construction subject to change. No return possible.
Open the catalog to page 14VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data | Controller selection Heating register (-H2), two-row CONTROLLER SELECTION Table 15: Heating register (-H2) Other controllers available on request. Makes Belimo, Gruner, Sauter, Siemens possible. Table 17: Controller selection Heating register (-H4), four-row Table 16: Heating register (-H4) Construction subject to change. No return possible.
Open the catalog to page 15VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Circuit diagrams Circuit diagram standard controller Compact controller NMV-D3-MP (make Belimo) VAV with analogue command signal VAV with lock (CLOSED) MP-Bus activation with integrated MP / actual value sig-■*TaO ...10V/2...10V 1 VAV command signal 0...10V CLOSED / VAV mode Lock mode (CLOSED): In the 2...10 V mode, the following function can be carried out with a 0 -10 V signal: Construction subject to change. No return possible.
Open the catalog to page 1632 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages