VAQS
1 / 19Pages

Catalog excerpts

VAQS - 2

08/23 - 2 Construction subject to change. Version: 09.05.2019 No return possible!

Open the catalog to page 2
VAQS - 3

Volumetric flow controller VAQS® Description ® The VAQS volumetric flow controller impresses with its simple design, high measuring precision and short length, meeting the majority of customary requirements of volumetric flow controllers. - simple design in accordance with the nominal size of the air duct. This simple design saves a lot of time and provides planning safety. - high controlling precision Due to its high controlling precision, the controller requires a straight flow section of only 1 x D even after bends. - Blades sealing airtight to DIN EN 1751, Class 3 - Housing leakage air...

Open the catalog to page 3
VAQS - 4

Volumetric flow controller VAQS® Field of application - for supply and return air systems - for constant or variable volumetric flows - Positive control Vmin, Vmax, "OPEN" or “CLOSED” - Suitable for constant and variable volumetric flow or duct pressure control - differential pressure range from 20 to 1000 Pa - for duct velocities of 1 - 12 m/s - for ambient temperatures of 0 - 50°C When installing volumetric flow controllers, for example in roof central units, in extreme cases, condensation can build up in the measuring pipes of the volumetric flow controller as a result of the large...

Open the catalog to page 4
VAQS - 5

Models and dimensions Dimensions VAQS® ...-DS0 Volumetric flow controller VAQS® Construction Housing - Galvanised sheet steel - Galvanized sheet steel with DD coating Blades - opposed, made of extruded aluminium profile Blade seal - made of PUR, silicone-free - for airtight design to DIN 1751, Class 3 Blade support - plastic Measuring rods - Aluminium Model VAQS® - Rectangular design, for duct connection to DIN EN 1505, for rectangular model, with blade seal. (air-tight to DIN EN 1751, Class 3) - Housing leakage air flow to DIN EN 1751, class B - with electric controller LMV/NMV-D3-MF, not...

Open the catalog to page 5
VAQS - 6

Volumetric flow controller VAQS® Available sizes and insertion loss for mineral wool silencer (-ZSQ) B (mm) The parameters KA (number of baffles), K (baffle strength ) and S (gap width ) depend on the width B. Construction subject to change.

Open the catalog to page 6
VAQS - 7

Volumetric flow controller VAQS® Technical data Inflow area A (m2) H (mm) Flow generated noise (A = 1 m2) Construction subject to change.

Open the catalog to page 7
VAQS - 8

Volumetric flow controller VAQS® Volumetric flow range for VAQS® When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! Volumetric flow range - this table specifies the complete measuring range of the standard controller (volumetric flow range). - If the customer absolutely wants a calibration curve different from 12 m/s, it must be specified! - When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! - If only one...

Open the catalog to page 8
VAQS - 9

Volumetric flow controller VAQS® Technical data for Belimo components Operating control Belimo components Measured value collection and control function The measured values are collected by two measuring rods favourable to the flow. The measuring openings are distributed over the measuring rods according to the median line method. The pressure differential formed on the measuring rods is determined by means of a dynamic or static measuring sensor. From these measuring results the middle value is formed, which gives a measured variable for the volume flow. The controller compares the actual...

Open the catalog to page 9
VAQS - 10

Volumetric flow controller VAQS®Circuit diagrams Compact controller Belimo make LMV/NMV-D3-MF - Attention: not MP-bus-capable VAV with analogue command signal VAV with lock (CLOSED)Mode 2-10V DC - + DC 24 V -1 VAV command signal 0...10V/2...10V MP / actual value signal 0...10V / 2...10V on site Switchover CLOSED / VAV operation _MP / actual value signal 0...10V / 2...10V on site Lock mode (CLOSED) In the 2 - 10 V mode, the following function can be carried out with a 0 - 10 V signal: Note: Please ensure mutual locking Function Damper CLOSED Vmin...Vmax CAV - Vmin Damper OPEN CAV - Vmax...

Open the catalog to page 10
VAQS - 11

Volumetric flow controller VAQS® LED table of functions for LMV/NMV-D3-MF Application N1 operation Function Status display Description / action - 24V power supply o.k. - VAV-Compact ready for operation Adaptation Address S1 service function Synchronisation Synchronisation started by: a) Operating / service unit b) Manual trigger device at the VAV-Compact c) Power ON behaviour S2 service function Adaptation Adaptation started by: a) Operating / service unit b) Key on the VAV-Compact a) Press both keys «Adaptation» & «Address» simultaneously b) VAV service will be activated: - until 24V...

Open the catalog to page 11
VAQS - 12

Volumetric flow controller VAQS® Setting the operating potentiometers / calculation formulae Actual value measurement via feedback signal U5 using a voltmeter or PC-Tool LMV/NMV-D3-MF Set value for Vmax V max = --------------- × 100% EW V max V nenn The required volumetric flow that is to flow at the 10 V DC command signal at terminal 3 (Y) or with positive control Vmax is set in % at the Vmax potentiometer of the controller, the ZTH-EU or PC-Tool. This value refers to the set Vnenn nominal volumetric flow. Set value for Vmin EW V Supply voltage: 24 V AC/DC (Terminals 1+2) Measurement...

Open the catalog to page 12
VAQS - 13

Volumetric flow controller VAQS®Technical data of the controller Functional control LMV/NMV-D3-MF (make Belimo) Dynamic pressure sensor, digital VAV controller and damper drive VAV-Compact solution Measuring principle : Pressure reading with volumetric flow Measuring range of the 2... ~ 450 Pa sensor : Supply voltage : Functional range : Power consumption: Dimensioning : Torque : Control function : Setting range Vmin/Vmax : AC 24 V 50/60 Hz; DC 24 V AC 19.2...28.8 V; DC 21.6...28.8V 2 W / 3W 3.5 VA / 5 VA min. 5 Nm/10 Nm at the rated voltage VAV/CAV/Open-Loop; Supply/return air or...

Open the catalog to page 13
VAQS - 14

Volumetric flow controller VAQS® Startup using PC-Tool Direct connection in the switch cabinet or socket (traditional application) ZTH EU as MP level converter Local connection via a service socket of the MF/MP or LON drive using a ZK1-GEN cable. Connection diagram 2 Description The ZTH EU is also a potential-free interface between the USB port of a PC and the Belimo MP bus. It is used to connect the Belimo PC-Tool directly to the MP bus or directly to a programmable MFT drive. Power supply The ZTH EU is supplied with power by the USB port. The MP bus voltage is obtained internally by means...

Open the catalog to page 14

All SCHAKO KG catalogs and technical brochures

  1. CNVA

    32 Pages

  2. AUDIX

    2 Pages

  3. DISA

    4 Pages

  4. UC-OH²

    2 Pages

  5. IGA

    2 Pages

  6. CDD

    2 Pages

  7. FBS

    18 Pages

  8. MINOPAB

    6 Pages

  9. PIL

    23 Pages

  10. MWS / MWK

    23 Pages

  11. ERK-SO

    43 Pages

  12. BKSYS

    18 Pages

  13. MINODSA

    6 Pages

  14. DKA

    6 Pages

  15. LAQ

    11 Pages

  16. VMPR/VMPQ

    29 Pages

  17. BKA-EN

    79 Pages

  18. CPL

    15 Pages

  19. AUDIX®

    25 Pages

  20. VREX

    26 Pages

  21. VQEX

    17 Pages

  22. VPEX

    18 Pages

  23. SVA-FS

    11 Pages

  24. NRWG

    22 Pages

  25. COMBIDSC

    26 Pages

  26. DSCXL

    17 Pages

  27. DSCU

    18 Pages

  28. DSCPL

    16 Pages

  29. DSCP

    15 Pages

  30. DSC

    37 Pages

  31. DO

    10 Pages

  32. VRAQ

    46 Pages

  33. UEKU

    6 Pages

  34. UEK

    6 Pages

  35. SS-K

    6 Pages

  36. DQJP

    9 Pages

  37. VOLKOM

    6 Pages

  38. DQJ

    38 Pages

  39. ALPETY

    16 Pages

  40. CTT

    23 Pages

  41. STV

    8 Pages

  42. KWB

    19 Pages

  43. GREENKIT

    20 Pages

  44. FKU

    31 Pages

  45. FKF

    29 Pages

  46. SGA

    5 Pages

  47. DBB

    27 Pages

  48. TVO

    8 Pages

  49. AL

    23 Pages

  50. SVA-FF

    15 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KF

    4 Pages

  54. JK

    16 Pages

  55. HK

    16 Pages

  56. FLAQ

    11 Pages

  57. FKW

    28 Pages

  58. FG

    14 Pages

  59. ERK-MB

    38 Pages

  60. DISA-H

    34 Pages

  61. DISA-360

    32 Pages

  62. DISA-300

    51 Pages

  63. CNV

    29 Pages

  64. BKA-UE

    35 Pages

  65. BAK-240

    16 Pages

  66. Aquaris-Silent

    38 Pages

  67. Aquaris_KWB

    20 Pages

  68. DISA-W

    43 Pages

  69. PILB/PILBR

    33 Pages

  70. DAV

    19 Pages

  71. 4DE

    18 Pages

  72. 4DF

    13 Pages

  73. DQC

    16 Pages

  74. DQDL

    16 Pages

  75. IDA

    21 Pages

  76. IKA

    23 Pages

  77. ZMD

    17 Pages

  78. DQF

    15 Pages

  79. DQJF

    12 Pages

  80. DQJA/DQJR

    10 Pages

  81. DQJSL

    17 Pages

  82. DQJSLC

    17 Pages

  83. DHV

    18 Pages

  84. DSARR

    7 Pages

  85. QA

    30 Pages

  86. PUSH

    23 Pages

  87. WQA

    12 Pages

  88. DSX-XXL

    23 Pages

  89. AUDIX®-ÜSG

    13 Pages

  90. SIA

    7 Pages

  91. SAR/SAQ/SARP

    13 Pages

  92. WDA

    32 Pages

  93. KGRR

    17 Pages

  94. DBBRR

    11 Pages

  95. WGARR

    7 Pages

  96. WGA

    29 Pages

  97. DKAPPs

    6 Pages

  98. EBE/EBP

    52 Pages

  99. VRAPPs

    20 Pages

  100. VRAR

    52 Pages

  101. MAK

    15 Pages

  102. DISA-Family

    4 Pages

  103. RMS

    11 Pages

  104. EasyBus

    24 Pages

  105. TSR

    5 Pages

  106. RS-F

    7 Pages

  107. RS

    15 Pages

  108. VLV

    31 Pages

  109. VARS

    26 Pages

  110. VAS

    26 Pages

  111. PIANO

    27 Pages

  112. MBM

    10 Pages

  113. MBE/MBP

    27 Pages

  114. DKG

    6 Pages

  115. ALAS-P

    5 Pages

  116. ALAS-F 125

    6 Pages

  117. ALAS

    10 Pages

  118. ALA-SO

    4 Pages

  119. ALA-R

    4 Pages

  120. ALA

    4 Pages

  121. LL

    7 Pages

  122. RR-Complete

    41 Pages

  123. DBBR

    6 Pages

  124. PA

    32 Pages

  125. LK

    12 Pages

  126. IB-R

    15 Pages

  127. IB-Q

    21 Pages

  128. KG

    19 Pages

  129. BSG

    19 Pages

  130. DSX-XXL-W

    25 Pages

  131. AUDIX®-AW

    20 Pages

  132. DSX

    25 Pages

  133. MINODSX

    6 Pages

  134. MINODSA

    6 Pages

  135. DSA

    15 Pages

  136. COMBIPIL

    11 Pages

  137. COMBIDQJ

    11 Pages

  138. MINOPAB

    6 Pages

  139. BDA

    11 Pages

  140. SPB

    10 Pages

  141. DISA-H

    34 Pages

  142. DISA-360

    32 Pages

  143. DISA-300

    51 Pages

  144. AQUARIS SILENT

    38 Pages

  145. NBS

    24 Pages

  146. CNV

    29 Pages

  147. CNVA

    32 Pages

  148. JK-LP/JK-LU

    15 Pages

  149. HKP / HKU

    16 Pages

  150. FKW

    16 Pages

  151. FLARE

    13 Pages

  152. RF

    7 Pages

  153. KGF

    9 Pages

  154. SVA-FF

    8 Pages

  155. BKA-Ü

    35 Pages

  156. BSK-RPR

    60 Pages

  157. BKP-EN

    40 Pages

  158. BAK-240

    6 Pages

  159. BAK-250

    14 Pages

  160. KF

    4 Pages

Archived catalogs

  1. DISA-601

    41 Pages

  2. DISA-B

    32 Pages