08/23 - 2 Construction subject to change. Version: 09.05.2019 No return possible!
Open the catalog to page 2Volumetric flow controller VAQS® Description ® The VAQS volumetric flow controller impresses with its simple design, high measuring precision and short length, meeting the majority of customary requirements of volumetric flow controllers. - simple design in accordance with the nominal size of the air duct. This simple design saves a lot of time and provides planning safety. - high controlling precision Due to its high controlling precision, the controller requires a straight flow section of only 1 x D even after bends. - Blades sealing airtight to DIN EN 1751, Class 3 - Housing leakage air flow...
Open the catalog to page 3Volumetric flow controller VAQS® Field of application - for supply and return air systems - for constant or variable volumetric flows - Positive control Vmin, Vmax, "OPEN" or “CLOSED” - Suitable for constant and variable volumetric flow or duct pressure control - differential pressure range from 20 to 1000 Pa - for duct velocities of 1 - 12 m/s - for ambient temperatures of 0 - 50°C When installing volumetric flow controllers, for example in roof central units, in extreme cases, condensation can build up in the measuring pipes of the volumetric flow controller as a result of the large temperature...
Open the catalog to page 4Models and dimensions Dimensions VAQS® ...-DS0 Volumetric flow controller VAQS® Construction Housing - Galvanised sheet steel - Galvanized sheet steel with DD coating Blades - opposed, made of extruded aluminium profile Blade seal - made of PUR, silicone-free - for airtight design to DIN 1751, Class 3 Blade support - plastic Measuring rods - Aluminium Model VAQS® - Rectangular design, for duct connection to DIN EN 1505, for rectangular model, with blade seal. (air-tight to DIN EN 1751, Class 3) - Housing leakage air flow to DIN EN 1751, class B - with electric controller LMV/NMV-D3-MF, not MP-bus-capable...
Open the catalog to page 5Volumetric flow controller VAQS® Available sizes and insertion loss for mineral wool silencer (-ZSQ) B (mm) The parameters KA (number of baffles), K (baffle strength ) and S (gap width ) depend on the width B. Construction subject to change.
Open the catalog to page 6Volumetric flow controller VAQS® Technical data Inflow area A (m2) H (mm) Flow generated noise (A = 1 m2) Construction subject to change.
Open the catalog to page 7Volumetric flow controller VAQS® Volumetric flow range for VAQS® When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! Volumetric flow range - this table specifies the complete measuring range of the standard controller (volumetric flow range). - If the customer absolutely wants a calibration curve different from 12 m/s, it must be specified! - When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! - If only one air...
Open the catalog to page 8Volumetric flow controller VAQS® Technical data for Belimo components Operating control Belimo components Measured value collection and control function The measured values are collected by two measuring rods favourable to the flow. The measuring openings are distributed over the measuring rods according to the median line method. The pressure differential formed on the measuring rods is determined by means of a dynamic or static measuring sensor. From these measuring results the middle value is formed, which gives a measured variable for the volume flow. The controller compares the actual value...
Open the catalog to page 9Volumetric flow controller VAQS®Circuit diagrams Compact controller Belimo make LMV/NMV-D3-MF - Attention: not MP-bus-capable VAV with analogue command signal VAV with lock (CLOSED)Mode 2-10V DC - + DC 24 V -1 VAV command signal 0...10V/2...10V MP / actual value signal 0...10V / 2...10V on site Switchover CLOSED / VAV operation _MP / actual value signal 0...10V / 2...10V on site Lock mode (CLOSED) In the 2 - 10 V mode, the following function can be carried out with a 0 - 10 V signal: Note: Please ensure mutual locking Function Damper CLOSED Vmin...Vmax CAV - Vmin Damper OPEN CAV - Vmax Contact...
Open the catalog to page 10Volumetric flow controller VAQS® LED table of functions for LMV/NMV-D3-MF Application N1 operation Function Status display Description / action - 24V power supply o.k. - VAV-Compact ready for operation Adaptation Address S1 service function Synchronisation Synchronisation started by: a) Operating / service unit b) Manual trigger device at the VAV-Compact c) Power ON behaviour S2 service function Adaptation Adaptation started by: a) Operating / service unit b) Key on the VAV-Compact a) Press both keys «Adaptation» & «Address» simultaneously b) VAV service will be activated: - until 24V supply...
Open the catalog to page 11Volumetric flow controller VAQS® Setting the operating potentiometers / calculation formulae Actual value measurement via feedback signal U5 using a voltmeter or PC-Tool LMV/NMV-D3-MF Set value for Vmax V max = --------------- × 100% EW V max V nenn The required volumetric flow that is to flow at the 10 V DC command signal at terminal 3 (Y) or with positive control Vmax is set in % at the Vmax potentiometer of the controller, the ZTH-EU or PC-Tool. This value refers to the set Vnenn nominal volumetric flow. Set value for Vmin EW V Supply voltage: 24 V AC/DC (Terminals 1+2) Measurement output...
Open the catalog to page 12Volumetric flow controller VAQS®Technical data of the controller Functional control LMV/NMV-D3-MF (make Belimo) Dynamic pressure sensor, digital VAV controller and damper drive VAV-Compact solution Measuring principle : Pressure reading with volumetric flow Measuring range of the 2... ~ 450 Pa sensor : Supply voltage : Functional range : Power consumption: Dimensioning : Torque : Control function : Setting range Vmin/Vmax : AC 24 V 50/60 Hz; DC 24 V AC 19.2...28.8 V; DC 21.6...28.8V 2 W / 3W 3.5 VA / 5 VA min. 5 Nm/10 Nm at the rated voltage VAV/CAV/Open-Loop; Supply/return air or stand-alone...
Open the catalog to page 1332 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages