Technical Documentation "Installation, Mounting and Operating In- SVA-FF Fire Damper Disc Valve PERFORMANCE DATA USABILITY CERTIFICATE • General building supervisory approval (abZ) • Preventing the transmission of fire from floor SPECIAL FEATURES CLASSIFICATION AND STANDARD Classification K90-18017 Application Ventilation systems in accordance with DIN 18017-3 Fire prevention Low pressure loss Low volume level Sheet steel design with epoxy resin powder coating (standard colour: RAL 9010 white; other RAL colours are possible upon request) A relatively high air inlet ring prevents soiled edges SCHAKO | Ferdinand Schad KG Phone +49 (0) 7463-980-0 D-78600 Kolbingen www.SCHAKO.de | [email protected]
Open the catalog to page 1Fire Damper Disc Valve SVA-FF Technical documentation Table of Contents Construction subject to change No return possible
Open the catalog to page 2Fire Damper Disc Valve SVA-FF Technical documentation Description DESCRIPTION The fire damper poppet valve SVA-FF is designed for installation in ventilation systems in accordance with DIN 18017-3. Besides, the fire damper poppet valve can also be mounted into systems in accordance with DIN 18017-3, for which the supply air is introduced through ducts. Its usage has been regulated by the general building supervisory approval (abZ) no. Z-41.3-674. Proper installation prevents spreading fire across floors. The fire damper poppet valves have fire resistance class K90-18017. The valve disc which...
Open the catalog to page 3Fire Damper Disc Valve SVA-FF Technical documentation Models and dimensions Nominal size Table 2: Dimensions of mounting frames (-ER) Available sizes Table 1: Available sizes of SVA-FF Replacement fusible link 70°C, size-dependent model When ordering, please state the nominal size of SVA-FF. Construction subject to change No return possible
Open the catalog to page 4Fire Damper Disc Valve SVA-FF Technical documentation Installation details INSTALLATION DETAILS Installation Installation of fire damper poppet valve type SVA-FF. The mounting frame is fastened on the duct or pipe by means of rivets or tapping screws. The valve is fastened in the mounting frame by rotating it in such a way that the valve becomes clamped in the mounting frame. To set the amount of air flow or change the gap width "s", (see Figure 1 page 4) rotate the valve disc. Installation of the air ducts with application of a ceiling mortar x ≤ 1.5 m Suspension, allowed tensile stress max....
Open the catalog to page 5Fire Damper Disc Valve SVA-FF Technical documentation Installation details F90: W = min. 40 mm Figure 4: Detail A F90: W = min. 40 mm F30: W = min. 24 mm Detail A alternatively Figure 7: Detail C F90: W = min. 40 mm Figure 5: Detail A alternatively Figure 8: Dimensioning of firestop boards Detail B AS øRD W = section = nominal size (NG) = wall thickness 1.) Spiral duct or flexible sheet steel duct 2.) The mounting frame is riveted from the inside to the standard spiral duct using steel rivets 3x6 3.) Mortar MG II-III or plaster mortar 4.) Non-fire-resistant suspended ceiling 5.) Shut-off damper...
Open the catalog to page 6Fire Damper Disc Valve SVA-FF Technical documentation Installation details Installation in or outside of ventilation shafts x ≤ 1.5 m Suspension, allowed tensile stress max. 6 N/mm² Figure 9: Installation in or outside of ventilation shafts Detail E Construction subject to change No return possible = section = nominal size (NG) = wall thickness 1.) Spiral duct or flexible sheet steel duct 2.) The mounting frame is riveted from the inside to the standard spiral duct using steel rivets 3x6 3.) Mortar MG II-III or plaster mortar 4.) Non-fire-resistant suspended ceiling 5.) Shut-off damper 6.) Three...
Open the catalog to page 7Fire Damper Disc Valve SVA-FF Technical documentation Technical data TECHNICAL DATA Pressure loss and noise level SVA-FF 100 Diagram 1: Pressure loss and noise level of SVA-FF 100 Diagram 3: Pressure loss and noise level of SVA-FF 150/160 Diagram 2: Pressure loss and noise level of SVA-FF 125 Diagram 4: Pressure loss and noise level of SVA-FF 200 Construction subject to change No return possible
Open the catalog to page 8Sound power level Table 4: Insertion loss The average values of the insertion from the duct to the room for ceiling installation are shown in the above table. Construction subject to change No return possible
Open the catalog to page 9Fire Damper Disc Valve SVA-FF Technical documentation Order code ORDER CODE OF SVA-FF EXAMPLE SVAFF-200-9010 Fire damper poppet valve type SVA-FF | Nominal size = 200 mm | 9010 = coating RAL 9010 ORDER DETAILS 01 - TYPE SVAFF = Fire damper poppet valve SVA-FF 02 - NOMINAL SIZE 100 - 125 - 150 - 160 - 200 in mm - always three digits 03 - PAINT 9010 = RAL colour white (standard) xxxx = RAL colour on request (always with 4 digits) SPECIFICATION TEXTS Fire damper poppet valve for mounting into ventilation systems in accordance with DIN 18017-3, or ventilation systems according to DIN 18017-3, for...
Open the catalog to page 10Fire Damper Disc Valve SVA-FF Technical documentation Service SERVICE Checking the function, cleaning, repair Polluted and damp air can impair the continuous operational safety. This is why, after commissioning the ventilation installation, all shut-off devices must be subjected to a functional test at a six-month interval according to section 5 of the general building supervisory approval Z-41.3-674. If two consecutive functional tests show no defects, the shut-off devices only have to be tested at a yearly interval. • Check connection opening and mounting frame (pos. 1) for soiling and clean...
Open the catalog to page 11Fire Damper Disc Valve SVA-FF Technical documentation Service SCHAKO Ferdinand Schad KG Steigstrasse 25-27 D-78600 Kolbingen Phone: +49- (0)7463 / 980-0 Fax: +49- (0)7463 / 980-200 E-Mail: [email protected] Sample Web: www.schako.de Functional test protocol for______________ _ Cons. No. Usability certificate: Series: _ Release device: Construction subject to change No return possible
Open the catalog to page 12Fire Damper Disc Valve SVA-FF Technical documentation Service SCHAKO Ferdinand Schad KG Steigstrasse 25-27 D-78600 Kolbingen Phone: +49- (0)7463 / 980-0 Fax: +49- (0)7463 / 980-200 E-mail: [email protected] Web: www.schako.de Sample Functional test protocol for____________________ Cons. No. ____________________ Defects found during the test on: Defects found during the test on: Defects found during the test on: Defects found during the test on: Construction subject to change No return possible
Open the catalog to page 1332 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages