

Catalog excerpts

09/16 - 2 Construction subject to change. Version: 28.11.2009 No return possible!
Open the catalog to page 2
Fire Damper Disc Valve SVA-FF Description The fire protection valve SVA-FF has been designed as thermal, automatically closing fire protection valve and is suitable for installation in return air systems. When installed correctly in fire protection walls or ceilings, it will prevent a fire from spreading through the duct system of the ventilation installation. For the fire protection valves of dimensions 0 100 mm, 0 125 mm, 0 150 mm, 0 160 mm and 0 200 mm, the specified fire resistance class is K90, and, accordingly, they have been rated as suitable for use. The valve disc which is...
Open the catalog to page 3
Available sizes Construction subject to change.
Open the catalog to page 4
Fire Damper Disc Valve SVA-FF Installation Installation of the fire protection disc valves type SVA-FF The mounting frame is fixed to the duct or pipe by means of rivets or tapping screws. The valve is fixed in the mounting frame by rotating it in such a way that the valve becomes clamped in the mounting frame. The fuse as trigger mechanism is built-in ready for use. To set the amount of air flow or change the gap width "S", rotate the shut-off plate., Installation of the air ducts with application of a ceiling mortar x 1,5 m Suspension, allowed tensile stress max. 6 N/m2 x 1,5 m...
Open the catalog to page 5
Fire Damper Disc Valve SVA-FF Detail A F90: W = min. 40mm Detail A alternatively F90: W = min. 40mm F30: W = min. 24mm AS = Section øRD = Nominal value (NW) W = Wall thickness 1.) Spiral duct or flexible sheet steel duct 2.) The mounting frame is riveted from the inside to the standardised spiral tube suing steel rivets 3x6 3.) Plaster or joint mastic 4.) Non-fire-resistant suspended ceiling 5.) Shut-off damper 09/16 - 6 Construction subject to change. Version: 28.11.2009 No return possible!
Open the catalog to page 6
Fire Damper Disc Valve SVA-FF Technical Data Pressure loss and noise level SVA-FF 100 09/16 - 7 Construction subject to change. Version: 28.11.2009 No return possible!
Open the catalog to page 7
Fire Damper Disc Valve SVA-FF NW To determine the sound power level in the octave band, the correction factor given in the table has to be added to the sound power level Lp10A dB(A) according to the following formula: Sound power level Lw = Lp10A + KF Specification texts Return air fire protection disc valve, for installation in walls, ceilings and ventilating shafts. The valves are used to prevent fires from spreading in ventilation ducts according to DIN 18017 Part 3. Resistance class K90. Consisting of a round valve casing and a valve disc made of sheet steel, painted to RAL 9010...
Open the catalog to page 8All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages