PUSH
1 / 23Pages

Catalog excerpts

PUSH - 2

03/04- 2 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 2
PUSH - 3

Displacement Diffuser Model PUSH Description Industrial plants with high levels of harmful emissions are usually ventilated using displacement ventilation, displacing harmful emissions from the occupied area towards the return air openings. The air is usually delivered via large capacity displacement diffusers located at floor level. This type of diffuser, however, wastes a lot of space in the occupied area and restricts the freedom of movement. The displacement diffuser type PUSH has been developed to prevent this waste of space. This diffuser is installed at a height of 3 - 4 m, i.e., 1 -...

Open the catalog to page 3
PUSH - 4

Construction Accessories Model PUSH-1A PUSH-1B Locking mechanism (-AA, fur PUSH-1A/-02/-03/-04) - Galvanised sheet steel (-SV, standard) at the diffuser casing - Stainless steel 1.4301 (-V2) at the diffuser casing Diffuser casing - Galvanised sheet steel, 360° perforated (-SV-...-360, standard) - Galvanised sheet steel, 270° perforated (-SV-...-270) - Stainless steel 1.4301 (-V2) Base plate and baffle plate - Galvanised sheet steel (-SV, standard) - Stainless steel 1.4301 (-V2) Chain (for PUSH-1A/-02/-03/-04) - Galvanised steel (-SV, standard) - Stainless steel 1.4301 (-V2) Damper leaf seal...

Open the catalog to page 4
PUSH - 5

Quick selection (horizontal throw) Models and dimensions Air throw pattern horizontal throw (cooling mode) Operating range of volumetric flow Construction subject to change.

Open the catalog to page 5
PUSH - 6

Displacement Diffuser Model Pltan Possible settings of the air throw pattern Different throw patterns are achieved by rotating the adjustable baffle plate or base plate into different directions by means of the chain. Intermediate positions are also possible. horizontal throw: cooling mode \ X X X diagonally downward throw: isothermal applicable to: PUSH-1 A/-1B/-02/-04/-06 Construction subject to change.

Open the catalog to page 6
PUSH - 7

Displacement Diffuser Model PUSHDimensions PUSH-1A Suitable for supply air temperatures of approx. 15°C to max. 40°C. Available sizes Construction subject to change.

Open the catalog to page 7
PUSH - 8

Displacement Diffuser Model Pltan Actuators for PUSH-04 Locking mechanism (-AA) Detail Y Detail Z Locking plate (-AW) for PUSH-1A/-02/-03/-04 on walls / columns Air throw setting (for PUSH-1A/-02/-03/-04): at the diffuser casing (with locking mechanism -AA): - Adjustable by chain. 3 m long from bottom edge of diffuser. On walls / columns (with locking plate -AW / with Bowden cable -BZ): - Adjustable by chain / cable. 3 m long from bottom edge of diffuser. Chain approx. 30 cm long. Construction subject to change.

Open the catalog to page 8
PUSH - 9

Displacement Diffuser Model PUSH Dimensions of accessories adjustable damper (-DV1) or adjustable damper with honeycomb air flow straightener (-DV2) Honeycomb air flow straightener Damper Blind rivet With adjustable damper with honeycomb air flow straightener (DV2), the honeycomb air flow straightener is fitted directly into the damper. Honeycomb air flow straightener (-WG1) For subsequent change of the air throw angle from 360° to 270° (for PUSH-...-360-... throw only). After mounting the cover plate correctly, the M8 screws have to be screwed into the perforation of the PUSH diffuser for...

Open the catalog to page 9
PUSH - 10

Displacement Diffuser Model PUSH Installation options Suspended installation (-F) (standard) Wall / column installation (-W) Section B-B Adjustment left-hand (standard) Adjustment right-hand Adjustment for type PUSH-1A/-1B/-02/-03/-04/-06. Detail W 03/04 - 10 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 10
PUSH - 11

Displacement Diffuser Model PUSH Technical data Pressure loss and noise level PUSH-...-250-... - - - 270° throw for wall / column installation 03/04 - 11 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 11
PUSH - 12

Displacement Diffuser Model Pltan PUSH-...-450-... The correction factors refer to the sound power evel LWA with horizontal air throw pattern. Damper position OPEN in % h = horizontal v = vertical ----270° throw for wall / column installation Construction subject to change.

Open the catalog to page 12
PUSH - 13

Displacement Diffuser Model PUSHMaximum end velocity of jet PUSH-...-350/355-. 270° throw for wall / column installation: vmax 270° = vmax x 1<8 PUSH-...-315-... 270° throw for wall / column installation: vmax 270° = vmax x 1-8 PUSH-...-400-... 270° throw for wall / column installation: vmax 270° = vmax x 1<8 270° throw for wall / column installation: vmax 270° = vmax x Construction subject to change.

Open the catalog to page 13
PUSH - 14

Displacement Diffuser Model PUSH PUSH-...-450-... 270° throw for wall / column installation: vmax 270° = vmax x 1.8 270° throw for wall / column installation: vmax 270° = vmax x 1.8 270° throw for wall / column installation: vmax 270° = vmax x 1.8 03/04 - 14 Construction subject to change. Version: 27.04.2020 No return possib

Open the catalog to page 14
PUSH - 15

Displacement Diffuser Model PUSH Jet path Suspended installation (-F), 360° throw (cooling mode) 03/04 - 15 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 15
PUSH - 16

Displacement Diffuser Model PltanWall / column installation (-W), 270° throw (cooling mode) ATn K 03/04 - 16 Version: 27.04.2020 Construction subject to change. No return possible!

Open the catalog to page 16
PUSH - 17

Displacement Diffuser Model PUSH Vertical throw (in heating mode) 03/04 - 17 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 17
PUSH - 18

Displacement Diffuser Model PUSH PUSH-...-450-... 03/04 - 18 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 18
PUSH - 19

Displacement Diffuser Model PUSH Induction ratio (only applicable with horizontal throw) Correction factor for 270° throw = i (-) x 0.714 Temperature ratio (only applicable with horizontal throw) Correction factor for 270° throw = TV (-) x 1.4 03/04 - 19 Construction subject to change. Version: 27.04.2020 No return possible!

Open the catalog to page 19
PUSH - 20

Technical data of electric actuators -E048 product Belimo (NM230A-F) Rated voltage: Functional range: Power consumption - Operation: - Idle position: - Dimensioning: Torque (rated torque): Running time: Sound power level: Protection class: Degree of protection: EMC: Low voltage directive: Ambient temperature: AC 100 ... 240 V, 50 / 60 Hz AC 85 ... 265 V 2.5 W @ nominal torque 0.6 W 5.5 VA Min. 10 Nm at the rated voltage 150s/90° max. 35 dB (A) II protective insulation Q IP54 in all mounting positions CE according to 89 / 336 / EEC CE according to 73 / 23 / EEC -30 ... +50°C Supply air...

Open the catalog to page 20

All SCHAKO KG catalogs and technical brochures

  1. CNVA

    32 Pages

  2. AUDIX

    2 Pages

  3. DISA

    4 Pages

  4. UC-OH²

    2 Pages

  5. IGA

    2 Pages

  6. CDD

    2 Pages

  7. FBS

    18 Pages

  8. MINOPAB

    6 Pages

  9. PIL

    23 Pages

  10. MWS / MWK

    23 Pages

  11. ERK-SO

    43 Pages

  12. BKSYS

    18 Pages

  13. MINODSA

    6 Pages

  14. DKA

    6 Pages

  15. LAQ

    11 Pages

  16. VMPR/VMPQ

    29 Pages

  17. BKA-EN

    79 Pages

  18. CPL

    15 Pages

  19. AUDIX®

    25 Pages

  20. VREX

    26 Pages

  21. VQEX

    17 Pages

  22. VPEX

    18 Pages

  23. SVA-FS

    11 Pages

  24. NRWG

    22 Pages

  25. COMBIDSC

    26 Pages

  26. DSCXL

    17 Pages

  27. DSCU

    18 Pages

  28. DSCPL

    16 Pages

  29. DSCP

    15 Pages

  30. DSC

    37 Pages

  31. DO

    10 Pages

  32. VRAQ

    46 Pages

  33. UEKU

    6 Pages

  34. UEK

    6 Pages

  35. SS-K

    6 Pages

  36. DQJP

    9 Pages

  37. VOLKOM

    6 Pages

  38. DQJ

    38 Pages

  39. ALPETY

    16 Pages

  40. CTT

    23 Pages

  41. STV

    8 Pages

  42. KWB

    19 Pages

  43. GREENKIT

    20 Pages

  44. FKU

    31 Pages

  45. FKF

    29 Pages

  46. SGA

    5 Pages

  47. DBB

    27 Pages

  48. TVO

    8 Pages

  49. AL

    23 Pages

  50. SVA-FF

    15 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KF

    4 Pages

  54. JK

    16 Pages

  55. HK

    16 Pages

  56. FLAQ

    11 Pages

  57. FKW

    28 Pages

  58. FG

    14 Pages

  59. ERK-MB

    38 Pages

  60. DISA-H

    34 Pages

  61. DISA-360

    32 Pages

  62. DISA-300

    51 Pages

  63. CNV

    29 Pages

  64. BKA-UE

    35 Pages

  65. BAK-240

    16 Pages

  66. Aquaris-Silent

    38 Pages

  67. Aquaris_KWB

    20 Pages

  68. DISA-W

    43 Pages

  69. PILB/PILBR

    33 Pages

  70. DAV

    19 Pages

  71. 4DE

    18 Pages

  72. 4DF

    13 Pages

  73. DQC

    16 Pages

  74. DQDL

    16 Pages

  75. IDA

    21 Pages

  76. IKA

    23 Pages

  77. ZMD

    17 Pages

  78. DQF

    15 Pages

  79. DQJF

    12 Pages

  80. DQJA/DQJR

    10 Pages

  81. DQJSL

    17 Pages

  82. DQJSLC

    17 Pages

  83. DHV

    18 Pages

  84. DSARR

    7 Pages

  85. QA

    30 Pages

  86. WQA

    12 Pages

  87. DSX-XXL

    23 Pages

  88. AUDIX®-ÜSG

    13 Pages

  89. SIA

    7 Pages

  90. SAR/SAQ/SARP

    13 Pages

  91. WDA

    32 Pages

  92. KGRR

    17 Pages

  93. DBBRR

    11 Pages

  94. WGARR

    7 Pages

  95. WGA

    29 Pages

  96. DKAPPs

    6 Pages

  97. EBE/EBP

    52 Pages

  98. VRAPPs

    20 Pages

  99. VRAR

    52 Pages

  100. MAK

    15 Pages

  101. DISA-Family

    4 Pages

  102. RMS

    11 Pages

  103. EasyBus

    24 Pages

  104. TSR

    5 Pages

  105. RS-F

    7 Pages

  106. RS

    15 Pages

  107. VLV

    31 Pages

  108. VARS

    26 Pages

  109. VAQS

    19 Pages

  110. VAS

    26 Pages

  111. PIANO

    27 Pages

  112. MBM

    10 Pages

  113. MBE/MBP

    27 Pages

  114. DKG

    6 Pages

  115. ALAS-P

    5 Pages

  116. ALAS-F 125

    6 Pages

  117. ALAS

    10 Pages

  118. ALA-SO

    4 Pages

  119. ALA-R

    4 Pages

  120. ALA

    4 Pages

  121. LL

    7 Pages

  122. RR-Complete

    41 Pages

  123. DBBR

    6 Pages

  124. PA

    32 Pages

  125. LK

    12 Pages

  126. IB-R

    15 Pages

  127. IB-Q

    21 Pages

  128. KG

    19 Pages

  129. BSG

    19 Pages

  130. DSX-XXL-W

    25 Pages

  131. AUDIX®-AW

    20 Pages

  132. DSX

    25 Pages

  133. MINODSX

    6 Pages

  134. MINODSA

    6 Pages

  135. DSA

    15 Pages

  136. COMBIPIL

    11 Pages

  137. COMBIDQJ

    11 Pages

  138. MINOPAB

    6 Pages

  139. BDA

    11 Pages

  140. SPB

    10 Pages

  141. DISA-H

    34 Pages

  142. DISA-360

    32 Pages

  143. DISA-300

    51 Pages

  144. AQUARIS SILENT

    38 Pages

  145. NBS

    24 Pages

  146. CNV

    29 Pages

  147. CNVA

    32 Pages

  148. JK-LP/JK-LU

    15 Pages

  149. HKP / HKU

    16 Pages

  150. FKW

    16 Pages

  151. FLARE

    13 Pages

  152. RF

    7 Pages

  153. KGF

    9 Pages

  154. SVA-FF

    8 Pages

  155. BKA-Ü

    35 Pages

  156. BSK-RPR

    60 Pages

  157. BKP-EN

    40 Pages

  158. BAK-240

    6 Pages

  159. BAK-250

    14 Pages

  160. KF

    4 Pages

Archived catalogs

  1. DISA-601

    41 Pages

  2. DISA-B

    32 Pages