
Floor displacement air diffuser PILB PILBR Ferdinand Schad KG SteigstraRe 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63 - 980 - 0 Fax +49 (0) 74 63 - 980 - 200 [email protected] schako.com
Open the catalog to page 105/24 - 2 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 2Model PILB-A PILB-B PILB-C PILB-D PILBR Floor displacement air diffuser PILB / PILBR Description The SCHAKO floor displacement air diffuser type PILB in rectangular and square design and the type PILBR in round design are suitable for installation in double floors in rooms of high thermal loads such as computer centres. The air flows horizontally out of the floor displacement air diffuser. This flow results in a rapid reduction of the temperature and velocity near the diffuser. The round floor displacement air diffuser (PILBR) consists of a faceplate and a dirt collection basket (at an extra...
Open the catalog to page 3Floor displacement air diffuser PILB / PILBR Models and dimensions Dimension PILB, square design (of the diffuser) Section A-A, one-sided throw (-1) Section A-A, two-sided throw (-2) (standard) Available sizes for PILB, square design NW PILB-C PILB-A (standard) Faceplate version, detail X Floor opening = ¨A + 2 mm Sizes cannot be combined. PILB, rectangular design Section B-B, one-way throw (-1) (of the diffuser) Section B-B, two-way throw (-2) (standard) Faceplate models, detail Y PILB-A PILB-B (standard) Available sizes for PILB, rectangular design NW Floor opening = B + 2 mm / L + 2 mm Sizes...
Open the catalog to page 4Floor displacement air diffuser PILB / PILBR PILBR-200 fastening prong Detail W outside (of faceplate) When mounting the faceplate to the baffle plate, the torque must not exceed 3 Nm. 05/24 - 5 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 5Floor displacement air diffuser PILB / PILBR Accessories - dimensions Plenum box (-AK) for PILB for PILB, with 1 spigot Sizes cannot be combined. For detail Z, see p. 7 1.) leak proofing on site Construction subject to change.
Open the catalog to page 6Floor displacement air diffuser PILB / PILBR Plenum box (-SK) for PILBR-200 1.) leak proofing on site Damper (-DK1) Rubber lip seal (-GD1) Detail Z 05/24 - 7 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 7Floor displacement air diffuser PILB / PILBR Dirt collection basket (-SFK1) for PILB, square design, without installation frame (-ER0) Available -SFK1 sizes for PILB, square design Available -SFK1 sizes for PILB, rectangular design Construction subject to change.
Open the catalog to page 8Floor displacement air diffuser PILB / PILBR Installation frame (-ER1) for PILB, square design Mounting ring with flange (-ER1) for PILBR-200 Available -ER1 sizes for PILB, square design Construction subject to change.
Open the catalog to page 9Floor displacement air diffuser PILB / PILBR Technical data Pressure loss and noise level PILB, square design in pressure floor applies to the models -A, -B, -C, -D Version: 17.02.2020 Construction subject to change. No return possible!
Open the catalog to page 10Floor displacement air diffuser PILB / PILBR PILB-. ..-500-500 PILB-. ..-600-600 Construction subject to change.
Open the catalog to page 11Floor displacement air diffuser PILB / PILBR with plenum box (-AK) and damper (-DK1) applies to the models -A, -B, -C, -D Damper position (DS): 0% = CLOSED 100% = OPEN PILB-...-300-300 05/24 - 12 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 12Floor displacement air diffuser PILB / PILBR PILB-. ..-500-500 PILB-. ..-600-600 Construction subject to change.
Open the catalog to page 13Floor displacement air diffuser PILB / PILBR Maximum end velocity of jet PILB, square design applies to models A, B, C, D 05/24 - 14 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 14Floor displacement air diffuser PILB / PILBR PILB-1-...-500-500, one-way throw 05/24 - 15 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 15Floor displacement air diffuser PILB / PILBR Temperature and induction ratios PILB, square design Temperature ratio PILB-...-300-300 05/24 - 16 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 16Floor displacement air diffuser PILB / PILBR Pressure loss and noise level PILB, rectangular design in pressure floor applies to the models -A, -B, -C, -D without dirt collection basket (-SKF0) with dirt collection basket (-SFK1) 05/24 - 17 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 17Floor displacement air diffuser PILB / PILBR PILB-...-1000-400 05/24 - 18 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 18Floor displacement air diffuser PILB / PILBR with plenum box (-AK) and damper (-DK1) applies to the models -A, -B, -C, -D Damper position (DS): 0% = CLOSED 100% = OPEN PILB-...-1000-150 05/24 - 19 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 19Floor displacement air diffuser PILB / PILBR PILB-...-1000-400 05/24 - 20 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 20Floor displacement air diffuser PILB / PILBR Maximum end velocity of jet PILB, rectangular design applies to the models -A, -B, -C, -D 05/24 - 21 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 21Floor displacement air diffuser PILB / PILBR PILB-1-...-1000-400, one-way throw 05/24 - 22 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 22Floor displacement air diffuser PILB / PILBR PILB-1-...-1000-600, one-way throw 05/24 - 23 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 23Floor displacement air diffuser PILB / PILBRTemperature and induction ratios PILB, rectangular design Temperature ratio PILB-...-1000-150 Construction subject to change.
Open the catalog to page 24Floor displacement air diffuser PILB / PILBR Induction ratio PILB-...-1000-150 05/24 - 25 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 25Floor displacement air diffuser PILB / PILBR Pressure loss and noise level PILBR in pressure floor with plenum box (-AK) and damper (-DK1) Damper position (DS): 0% = CLOSED 100% = OPEN 05/24 - 26 Construction subject to change. Version: 17.02.2020 No return possible!
Open the catalog to page 2632 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages