Catalog excerpts

Sound-damped Volumetric flow controller Piano / Piano-S Ferdinand Schad KG SteigstraBe 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63 - 980 - 0 Fax +49 (0) 74 63 - 980 - 200 info@schako.de www.schako.de
Open the catalog to page 1
08/19 - 2 Construction subject to change. Version: 17.08.2017 No return possible!
Open the catalog to page 2
Sound-damped volumetric flow controller model Piano / Piano-S Description The shorter design compared with conventional pressure reducing boxes simplifies mounting in constricted places and allows space to be saved due to the low overall height. Due to the smaller dimensions, installation has been radically simplified. The sound-damped volumetric flow controller type Piano with rectangular connection can be connected to rectangular ducts to DIN 24190 or to spiral ducts to DIN 24145 via a transition piece. This allows the sound-damped volumetric flow controller type Piano to be used for...
Open the catalog to page 3
with damper leaf open Construction Housing - Standard (-): made of galvanised sheet steel, lined with mineral wool (abrasion-resistant up to an air velocity of 20 m/s in the duct). Damper leaves - Standard (-): made of extruded aluminium profile, tightness element made of plastic (polyurethane). Measuring cross - Standard (-): made of extruded aluminium profile Gear wheel segments - Steel, peripheral, arranged on one side, covered. model Piano Piano-S ...-E ...-P ...-...-Z ...-...-A ...-...-A-DD ...-...-...-R ...-...-...-L Standard Extended version with electronic controller with pneumatic...
Open the catalog to page 4
Piano: NW 1-8 = length one-piece Piano-S: NW 1-7 = length one-piece NW 8 = length two-piece Available sizes Construction subject to change.
Open the catalog to page 5
Rubber lip seal (-GD, with -US only) Detail X Dimensions of accessories Transition piece (-US) (rectangular/round) high-pressure side, for supply air or return air Available sizes transition piece (-US) Construction subject to change.
Open the catalog to page 6
Available sizes heating register (-H2/-H4) Construction subject to change.
Open the catalog to page 7
Sound-damped volumetric flow controller model Piano / Piano-S Technical data Static minimum pressure difference Volumetric flow range NW Attention, the following specifications are important for the programming of the volumetric flow controllers: - this table merely specifies the complete measuring range of the controller (volumetric flow range), calibration curve 12 m/s - If the customer absolutely wants a calibration curve, it must be specified! - When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed!...
Open the catalog to page 8
Sound-damped volumetric flow controller model Piano / Piano-SFlow generated noisePiano-Z NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 9
Sound-damped volumetric flow controller model Piano / Piano-SFlow generated noisePiano-A NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 10
Sound-damped volumetric flow controller model Piano / Piano-SFlow generated noisePiano-S-Z NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 11
Sound-damped volumetric flow controller model Piano / Piano-SFlow generated noisePiano-S-A NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 12
Sound-damped volumetric flow controller model Piano / Piano-SRadiated noisePiano-Z / Piano-S-Z NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 13
Sound-damped volumetric flow controller model Piano / Piano-SRadiated noisePiano-A / Piano-S-A NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 14
Sound-damped volumetric flow controller model Piano / Piano-SRadiated noisePiano-Z-FDS / Piano-S-Z-FDS NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 15
Sound-damped volumetric flow controller model Piano / Piano-SRadiated noisePiano-A-FDS / Piano-S-A-FDS NW Version: 17.08.2017 No return possible! Construction subject to change.
Open the catalog to page 16
Sound-damped volumetric flow controller model Piano / Piano-SHeating register (-H2) with 2 duct rows with 4 duct rows Construction subject to change.
Open the catalog to page 17
Connection diagram VRD3-SO Connection diagram VRP AC 24 V A Connection via safety trans Positive control VRPPositive control VRD3-SO Overview control signals / functions Signal terminal / Function *) requires AC 24 V power supply08/19 - 18 Version: 17.08.2017 Construction subject to change. No return possible!
Open the catalog to page 18
Circuit diagram controller NMV-D3-MP CAV function for NMV-D3-MP Mode setting Construction subject to change. Damper CLOSED Notes: - Supply voltage via safety transformer! - The connections 1 and 2 (AC/DC 24V) and 5 (MP signal) must be connected to readily accessible terminals (room controller, floor distributor, switch cabinet, etc.), in order to allow them to be accessed by the PC-Tool for diagnostic and service work.
Open the catalog to page 19
Sound-damped volumetric flow controller model Piano / Piano-S LED table of functions for NMV-D3-MP Description / action ® LED 1 power ® LED 2 status Address Status display - 24V power supply o.k. - VAV-Compact ready for operation Synchronisation started by: a) Operating / service unit b) Manual trigger device at the VAV-Compact c) Power ON behaviour J Start Synch time Adaptation started by: a) Operating / service unit b) Key on the VAV-Compact J Start Adaptation time L a) Press both keys «Adaptation» & «Address» simultaneously b) VAV service will be activated: - until 24V supply is switched...
Open the catalog to page 20
Sound-damped volumetric flow controller model Piano / Piano-S Technical data of the controllers NMV-D3-MP (make Belimo) Dynamic pressure sensor, digital VAV controller and damper drive as communication-capable VAV-Compact solution. VRD3-SO with integrated dynamic differential pressure sensor VRP For static differential pressure control with separately available sensors VFP-100, 300 or 600 Measuring principle : Measuring range of the sensor : Supply voltage : Functional range : Power consumption : Dimensioning : Torque : Control function : Pressure reading with volumetric flow 2... ~ 450 Pa...
Open the catalog to page 21All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages