

Catalog excerpts

01/14 - 2 Construction subject to change. Version: 21.03.2019 No return possible!
Open the catalog to page 2
Ventilation Grille PA Description The ventilation grille PA is suitable for use in supply and return air installations and for installation in walls, ceilings, floors and ventilation ducts. For air deflection, horizontal or vertical (for floors only), fixed blade profiles are attached at the front side. For wall mounting, basic type PA...-01 with concealed mounting (-VM, standard) or screw mounting (-SM) is suitable. The basic type PA-...-03 with concealed mounting (-VM) is suitable for floor installation. According to the required air throw pattern, the blade profile of the basic types...
Open the catalog to page 3
Ventilation Grille PAAccessories Plenum box (-AK) (only for PA-...-01 / PA-...-2a / PA-...-10) Screw mounting (-SM) - Galvanised sheet steel - PA-...-01 / PA-...-2a / PA-...-2b / PA-...-2c - With connection spigot: - lateral (-S1, standard) - from above (-S0) - front side (-S4) Damper (-DK1, for AK-S1) - In plenum box - Damper made of galvanised sheet steel - Damper fastening made of plastic Rubber lip seal (-GD1) - Special rubber, on plenum box adapter Corner angle 90° (-EW) - With dummy plate made of galvanised sheet steel painted to RAL 9005 (black) (only for PA-...-03 / PA-...-05 /...
Open the catalog to page 4
Ventilation Grille PA Models and dimensions For wall and ceiling mounting and installation in ventilation ducts Dimensions PA-...-01-...-VM All models consist of basic type PA-...-01 PA-...-2a-... All combined lengths and heights available. Other sizes available on request. PLA = number of profiled blades Available sizes Construction subject to change.
Open the catalog to page 5
Ventilation Grille PA Ventilation grille PA-...-01 / PA-...-2a / PA-...-2b / PA-...-2c, as band 2-part if length of band BL < 2025 mm Ventilation grille bands can be supplied only with screw mounting (SM). Construction subject to change.
Open the catalog to page 6
Ventilation Grille PADimensions PA-...-10-...-VS-... Counter pole brace on-site Available sizes All combined lengths and heights available. Other sizes available on request. Hit-and-miss damper not possible. PLA = number of profiled blades Construction subject to change.
Open the catalog to page 7
Ventilation Grille PAVentilation grille PA-...-10, as band 2-part if length of band BL < 2025 mm \ Ventilation grille bands can be supplied only with concealed mounting (-VS). ES = End piece DIF = Difference TS = Section(s) BL = Length of band BL1 = Total length Construction subject to change.
Open the catalog to page 8
Ventilation Grille PAFor floor mounting Dimension PA-...-03-...-VM-... Available sizes All models consist of basic type PA...-3 PA-...-05-...Frame profile PA-...-03 / PA-...-05 / PA-...-06 / PA-. ..-07 All combined lengths and heights available. Other sizes available on request. PLA = number of profiled blades Grille insert fastening (standard model) Construction subject to change.
Open the catalog to page 9
Ventilation Grille PA Ventilation grille PA-...-03 / PA-...-05 / PA-...-06 / PA-...-07, as band 2-part if length of band BL ≤ 2025 mm multi-part for a length of band BL > 2025 mm Ventilation grille bands can be supplied only with concealed mounting (-VM). Fishplate (VL) Standard for band design End piece Difference Section(s) Length of band 01/14 - 10 Construction subject to change. Version: 21.03.2019 No return possible!
Open the catalog to page 10
Ventilation Grille PA Dimensions of accessories For wall and ceiling mounting and installation in ventilation ducts Plenum box (-AK-34-...) with lateral spigot (-S1) Only for PA-...-01 / PA-...-2a Grilles cannot be fitted with a hit-and-miss damper if a plenum box is attached, i.e., it can either be fitted with a hit-and-miss damper or a plenum box. Construction subject to change.
Open the catalog to page 11
Ventilation Grille PA Spigot arrangement - Lateral spigot (-S1, standard) - Spigot from above (-S0) - Spigot front side (-S4) Dimensions and prices for spigot from above (-S0) and spigot front side (-S4) upon request. Detail X external (-Ia) Concealed plates can be bent outwards, if necessary. Rubber lip seal (-GD1) Detail Y 01/14 - 12 Construction subject to change. Version: 21.03.2019 No return possible!
Open the catalog to page 12
Ventilation Grille PA Plenum box (-AK-34-...) with lateral spigot (-S1) as band Only for PA-...-01 / PA-...-2a 2-part if length of band BL < 2025 mm BL = Length of band BL1 = Total length of grille (BL1 = BL + 23) KL = Length of box KL1 = Length of box end piece (KL1 = ES - 17) n = Number Construction subject to change
Open the catalog to page 13
Plenum box (-AK-35-...) with lateral spigot (-S1) Only for PA-...-10 Available sizes AK-35-...-S1 only for PA-...-10 - Lateral spigot (-S1, standard) - Spigot from above (-S0) - Spigot front side (-S4) Dimensions and prices for spigot from above (-S0) and spigot front side (-S4) upon request. Construction subject to change.
Open the catalog to page 14
Ventilation Grille PA Plenum box (AK-35-...) with lateral spigot (-S1) as band for PA-...-10 2-part if length of band BL < 2025 mm BL = Length of band BL1 = Total length of grille (BL1 = BL + 10) KL = Length of box KL1 = Length of box end piece (KL1 = ES - 9) n = Number Construction subject to change.
Open the catalog to page 15
Ventilation Grille PA For wall and ceiling mounting and installation in ventilation ducts Corner angle (-EW-...-01...) For ventilation grille band PA-...-01 / PA-...-2a / PA-...-2b / PA-...-2c For floor mounting Corner angle (-EW-...-03-...) For ventilation grille band PA-...-03 / PA-...-05 / PA-...-06 / PA-...-07 Dummy plate Dummy plate Corner angles can only be manufactured as dummy plates, i.e., without a plenum box. The corner angle is angled by 90° and has a flange length of 450 mm. The dummy plate used is made of Zincor and painted to RAL 9005 (black). Corner angles can only be...
Open the catalog to page 16
Ventilation Grille PAInstallation frame (-ER1/-ER2) for ventilation grilles for wall and ceiling mounting and installation in ventilation ducts PA-...-01 / PA-...-2a / PA-...-2b / PA-...-2c Length L < 825 mm =4 wall anchors Length L > 825 mm =6 wall anchors Installation frames for grille bands are supplied with plug-in connections. Assembly rails are additionally attached, they can be easily removed by turning, once the grille has been mounted in the wall. All installation frames are supplied without wall anchors. Wall anchors available at an extra charge only. Construction subject to change.
Open the catalog to page 17All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages