fCHAKMulti-Leaf DamperModel JK-LP / JK-LU Leakage air flow with control damper closed according to DIN EN 1751, up to class 4 Ferdinand Schad KG SteigstraGe 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63 - 980 - 0 Fax +49 (0) 74 63 - 980 - 200 info@schako.de www.schako.de
Open the catalog to page 1
08/11 - 2 Construction subject to change. Version: 15.01.2018 No return possible!
Open the catalog to page 2
Multi-Leaf Damper JK-LP / JK-LU Description Application range The multi-leaf dampers types JK-LP 180 and JK-LU 180 are used in ventilation and air-conditioning systems as control, throttle or shut-off dampers for the pressure and volumetric flow regulation. The flow-favouring aluminium blades are adjusted together, rotating in opposite directions, via external plastic gear wheels. The external arrangement of the gears has the benefit that in comparison to internally arranged wheels exposed to the air flow, they do not become soiled so quickly. A cover plate protects the gear wheels from...
Open the catalog to page 3
currentless currentless currentless currentless currentless currentless Construction Seals - Special rubber Hollow-body blades - Aluminium profile, flow-favouring and torsion-resistant jointly adjustable in opposite directions Bearing - JK-LP 180: plastic bearing - JK-LU 180: sintered bearing Frame Profiled sheet steel galvanised 1.5 mm, dimensionally sta-- ble - Depth of the frame = 180 mm - with profiled connection frame - with frame bores (at an extra charge): on one side (-RB1) - with frame bores (at an extra charge): on two sides (-RB2) Gear wheels - Plastic, externally fitted, on one...
Open the catalog to page 4
Multi-Leaf Damper JK-LP / JK-LU Models and dimensions Dimensions JK-LP 180 (with plastic bearing) JK-LU 180 (with sintered bearing) When selecting the multi-leaf dampers, the permitted width must be selected according to the total pressure loss (see selection table above). Max. differential pressure 1000 Pa. Construction subject to change. All combined lengths and widths available!
Open the catalog to page 5
“HAK# Corner angle As standard, multi-leaf dampers are supplied with corner angles. The special form of the corner holes allows them to be connected to the connection systems available on the market (e.g. Metu system M 2/M 3) Extended driving axle (-VA) Driving axle left Driving axle right The number of holes does not include the 4 corner holes. Number of holes All combined lengths and heights available. Projection length z = max. 150 mm only together with bearing block (at an extra charge) The above illustration shows the division of multi-leaf dampers greater than 1998 mm in height. The...
Open the catalog to page 6
Multi-Leaf Damper JK-LP / JK-LU Multi-leaf damper divided vertically The figure opposite shows the division of multi-leaf dampers greater than 1998 mm in width. It is not possible to join the two sections. Drive side 1 "left" and 1 "right". The primed mounting frame 35/35/4 is only available on special request. Vertically and horizontally divided multi-leaf dampers The figure opposite shows the division of multi-leaf dampers greater than 1998 mm in height and width. The blades in the two sections on top of each other are joined by a coupling rod. It is not possible to join the horizontally...
Open the catalog to page 7
Angle counter frame (-WG) Multi-Leaf Damper JK-LP / JK-LU Dimensions of accessories Assembly detail Mounting frame (-ER) Flat-steel counter frame (-FG) Multi-leaf dampers can be additionally fitted with: 1.) Mounting frame 35/35/4 with riveted wall anchor (-ER) 2.) Flat-steel counter frame 33/5 (-FG) 3.) Angular counter frame 30/30/3 (-WG) undrilled or drilled. All frames are supplied in primed design. Mounting frame (-ER) Wall anchor arrangement Height (mm): H < 1003 ^ 2 anchors on each side H > 1003 ^ 3 anchors on each side 797 < B < 1003 ^ 2 anchors on each side B > 1003 ^ 3 anchors on...
Open the catalog to page 8
Electric limit switches can be installed to indicate position or to perform switching functions Installation options: - Damper position “CLOSED” 1 limit switch (-ES1Z) - Damper position “OPEN” 1 limit switch (-ES1A) - with 2 limit switches, “CLOSED” and “OPEN” (-ES2) - 1 NC / 1 NO contact (Ue 240V le 6 A, on request): - Standard model (-ES1M) - Explosion-proof model (-ES1Ex) If an electric actuator or pneumatic servo cylinder is used, the limit switches can also be installed as shown in the drawing. Integrated limit switches The electric actuators are available with integrated / mounted...
Open the catalog to page 9
Multi-Leaf Damper JK-LP / JK-LU Installation next to multi-leaf damper (at an extra charge) Installation above multi-leaf damper (at an extra charge) with pneumatic servo cylinder H = 201-565 Console type II (screwed-on) Console type I (screwed-on) 08/11 - 10 Construction subject to change. Version: 15.01.2018 No return possible!
Open the catalog to page 10
Duct connection Technical data Pressure loss and noise level Pressure loss Open connection Correction factor (for flow generated noise) Construction subject to change.
Open the catalog to page 11
«h*k#Multi-Leaf Damper JK-LP / JK-LUSelection actuator / servo cylinder JK-LP / JK-LU-E (with electric actuator) The electric actuator or pneumatic cylinder can also be installed at a later stage. When an electric actuator is fitted, a control panel must be attached next to or above the damper during mounting. For standard mounting of a pneumatic servo cylinder, use control panel type I for heights of up to < 565 and control panel type II for heights from > 634. When a thrust actuator or servo cylinder is mounted on site, it is recommended also ordering the bearing block, in order to ensure...
Open the catalog to page 12
model Electric actuators Electric terminals 24 V AC/DC, 230 V AC Two-point Three-pointElectric terminals 24 V AC/DC, 230 V AC Two-point Pressure loss Intake velocity, blower stream velocity, outflow velocity, relative to B x H Blade position A-weighted sound power level [LWA = LWA1 + KF] A-weighted sound power level relative to 1 m2 Density Correction factor Face area Height Width Leak air volume Leak air volume Leaf area Construction subject to change.
Open the catalog to page 13
«h*k#Multi-Leaf Damper JK-LP / JK-LU Order details | manually adjustable""! with position feedback 2-10 V without integrated limit switches with integrated limit switches -IS2 Accessories: Mounting frame -ER Flat-steel counter frame -FG Angle steel counter frame -WG Extended drive axle (only possible for use with bearing block) -VA Order example: JK-LP 180-E1-ES1Z-RB1 Unless stated otherwise, the thick-frame model will be delivered! 08/11 - 14 No return possible! Construction subject to change.
Open the catalog to page 14All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages