Catalog excerpts

01/09 - 2 Construction subject to change. Version: 24.11.2017 No return possible!
Open the catalog to page 2
Description Supply and return air grille especially suitable for duct connec- Installati0n Situati0n tion with horizontal or vertical individually adjustable air deflection blades on the front side. With hit-and-miss damper for air volume regulation Construction Blades and frames - Sheet steel painted to RAL 9010 (white) (-SB-9010) - Electrolytically galvanised sheet steel (standard) (-SV-0000) Hit-and-miss damper - Electrolytically galvanised sheet steel (only IB-R-08-... and IB-R-15-...) Model IB-R-01-... - horizontal air deflection blades IB-R-08-... - Horizontal air deflection blades...
Open the catalog to page 3
Ventilation Grille Model IB-R Models and dimensions Dimensions IB-R-01-... All combined lengths and heights available! Other sizes available on request. Construction subject to change.
Open the catalog to page 4
All combined lengths and heights available! Other sizes available on request. Construction subject to change.
Open the catalog to page 5
Ventilation Grille Model IB-R Technical data Pressure loss and noise level Supply air face velocity IB-R-... with hit-and-miss damper (supply air) Hit-and-miss damper position OPEN in % 01/09 - 6 Construction subject to change. Version: 24.11.2017 No return possible!
Open the catalog to page 6
Ventilation Grille Model IB-R Return air face velocity IB-R-... with hit-and-miss damper (return air) Hit-and-miss damper position OPEN in % Supply and return air Face area in (m²) Correction factor Supply air 01/09 - 7 Construction subject to change. Version: 24.11.2017 No return possible!
Open the catalog to page 7
Ventilation Grille Model IB-R Maximum end velocity of jet Supply air without coanda effect Supply air with coanda effect 01/09 - 8 Construction subject to change. Version: 24.11.2017 No return possible!
Open the catalog to page 8
Ventilation Grille Model IB-R Jet path Supply air without coanda effect Heating Cooling Critical throw Supply air with coanda effect 01/09 - 9 Construction subject to change. Version: 24.11.2017 No return possible!
Open the catalog to page 9
“HAk#Ventilation Grille Model IB-RMaximum penetration In heating mode Construction subject to change.
Open the catalog to page 10
Ventilation Grille Model IB-R Induction and temperature ratios Supply air without coanda effect Supply air with coanda effect Minimum distances Supply air without coanda effect Supply air with coanda effect If the selected minimum distance "z" is less than (x • 0.2), the grille is referred to as a grille band. 01/09 - 11 Construction subject to change. Version: 24.11.2017 No return possible!
Open the catalog to page 11
Ventilation Grille Model IB-RCorrection factor (for scattered air jet) Blade position opposite to one another (-LGEG) Blade position straight diverging Blade position The angle of propagation of the air jet and thus the length of throw can be affected by adjusting the vertical air deflection blades. Layout example Assume: Ventilation grille IB-R-08-... H = 115 mm L =615 m (with coanda effect) x =6.0 m Find: Pressure loss, sound level, end velocity of jet, critical throw, induction and temperature ratios. Solution: - Pressure loss (page 6): Apt = 22 Pa - Weighted sound power level page 6/7...
Open the catalog to page 12
Ventilation Grille Model IB-R Legend Vzu (m3/h) [l/s] = Vab (m3/h) [l/s] = Vx (m3/h) [l/s] = vmax (m/s) = Supply air volume Return air volume total air jet volume at point x Maximum end velocity of jet Duct velocity Intake velocity, blower stream velocity, outflow velocity, relative to Astirn Face area horizontal throw vertical throw Critical throw Density Pressure loss A-weighted sound power level [Lwa = lwai + KF] A-weighted sound power level, relative to Astirn = 0.08 m2 AT0 (K) = Temperature difference between supply air temperature and room temperature (AT0 = tzu - tR) AToh (K) =...
Open the catalog to page 13
Ventilation Grille Model IB-R Order code IB-R 01 Sample IB-R-01-0615-115-N-L000-SB-9010-SM-ER0 Ventilation grille type IB I for duct installation I horizontal pivoting air deflection blades on the front side I grille length 615 mm I grille height 115 mm | single length | blade position straight | sheet steel | painted to RAL9010 | with screw mounting | without installation frame Order details 01 - Type IB = Ventilation Grid Model IB 02 - Model R = For duct installation 03 - Blades 01 = Horizontal pivoting air deflection blades at the front side 08 = same as IB-R-01, additionally with...
Open the catalog to page 14
Ventilation Grille Model IB-R Specification texts Supply and return air grille for installation in sheet metal / spiral ducts. Consisting of horizontal, pivoting and individually adjustable air deflection blades on the front side. Frames and blades made of sheet steel painted to RAL 9010 (white) or of electrolytically galvanised sheet steel. Fastening by means of screw mounting (-SM). Product: SCHAKO type IB-R-01-... - With front side vertical, pivoting and individually adjustable air deflection blades. Product: SCHAKO type IB-R-10-... - With front side horizontal, pivoting and individually...
Open the catalog to page 15All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages