Catalog excerpts

08/10 - 2 Construction subject to change. Version: 15.01.2018 No return possible!
Open the catalog to page 2
Description Application range Multi-leaf damper types HKP and HKU can be used in air-conditioning and ventilation systems as control, throttle or shut-off dampers to control pressure and volumetric flow. The flow-favouring blades are adjusted together, rotating in opposite directions, via external plastic gear wheels. The external arrangement of the gears has the advantage that, in comparison with internally arranged gears exposed to the air flow, they do not become dirty that quickly. A cover plate protects the gear wheels from outside dirt and reduces the personal accident danger during...
Open the catalog to page 3
Multi-Leaf Damper Models HKP / HKU model HKP - with plastic bearing HKU - with sintered bearing HKU 180-K - with brass bearing (only H = 100 available) Accessories - Add-on parts - Mounting frame 35/35/4 with riveted wall anchor (-ER) - Flat-steel counter frame 33/5 (-FG) - Angular steel counter frame 30/30/3 (-WG) - Locking device (-FV, only HKU / HKP), console and hand lever mounted ex works to the multi-leaf damper. - Extended driving axle (-VA) only available with bearing block (at an extra charge) - Bearing block (-LB) - Electric actuator, 2/3-point - 5 Nm, 24 V AC/DC (-E1) / 230 V AC...
Open the catalog to page 4
Multi-Leaf Damper Models HKP / HKU Models and dimensions Dimensions HKP (with plastic bearing) HKU (with sintered bearing) Available sizes HKP / HKU Standard series of dimensions Note: The dimensions w1, w2 and x are rounded values! All combined lengths and heights available. Construction subject to change.
Open the catalog to page 5
As standard, multi-leaf dampers are supplied with corner angles. The special form of the corner holes allows them to be connected to the connection systems available on the market (e.g. Metu system M 2/M 3) The number of holes does not include the 4 corner holes. Number of holes B All combined lengths and heights available. The above figure shows the division of multi-leaf dampers greater than 1998 mm and 2000 mm in height. The blades in the two sections are joined by a coupling rod. The primed mounting frame 35/35/4 is only available on special request. Construction subject to change.
Open the catalog to page 6
Multi-Leaf Damper Models HKP / HKU Multi-leaf damper divided vertically The figure opposite shows the division of multi-leaf dampers greater than 1998 mm and 2000 mm in width. It is not possible to join the two sections. Drive end 1 x "left" and 1 x "right". The primed mounting frame 35/35/4 is only available on special request. Vertically and horizontally divided multi-leaf dampers The figure opposite shows the division of multi-leaf dampers greater than 1998 mm and 2000 mm in width and height. The blades in the two sections on top of each other are joined by a coupling rod. It is not...
Open the catalog to page 7
Multi-Leaf Damper Models HKP / HKU Dimensions of accessories Assembly detail Mounting frame (-ER) Flat-steel counter frame (-FG) Angle counter frame (-WG) Multi-leaf dampers can be additionally fitted with: 1.) Mounting frame 35/35/4 with riveted wall anchor (-ER) 2.) Flat-steel counter frame 33/5 (-FG) 3.) Angular counter frame 30/30/3 (-WG) undrilled or drilled. All frames are supplied in primed design. Mounting frame (-ER) Wall anchor Wall anchor arrangement Height (mm): H < 1000 or 1003 ^ 2 anchors on each side H > 1000 or 1003 ^ 3 anchors on each side Bearing block (-LB) A bearing...
Open the catalog to page 8
Multi-Leaf Damper Models HKP / HKU with electric actuator Standard assembly limit switch CLOSED OPEN Installation options: Integrated limit switches The electric actuators are available with integrated / mounted limit switches. Integration option: Damper position "CLOSED" 1 limit switch (-ES1Z) - with 2 limit switches "CLOSED" and "OPEN" (-IS2) Damper position "OPEN" 1 limit switch (-ES1A) with 2 limit switches, "CLOSED" and "OPEN" (-ES2) Electric limit switches can be installed to indicate position or to perform switching functions If an electric actuator or pneumatic servo cylinder is...
Open the catalog to page 9
Multi-Leaf Damper Models HKP / HKU Installation next to multi-leaf damper (at an extra charge) Installation above multi-leaf damper (at an extra charge) with pneumatic servo cylinder H = 201-565 or H = 200-600 Console type I (screwed-on) Console type II (screwed-on) 08/10 - 10 Construction subject to change. Version: 15.01.2018 No return possible!
Open the catalog to page 10
Technical data Volumetric flow range Leak air volume with closed damper (HKU / HKP) Pressure loss and noise level Pressure loss (as a function of the blade position a) Open connection Correction factor (for flow generated noise) Construction subject to change.
Open the catalog to page 11
Multi-Leaf Damper Models HKP / HKU Selection actuator / servo cylinder HKP / HKU-E (with electric actuator) HKP / HKU-P (with pneumatic servo cylinder) The electric actuator or pneumatic cylinder can also be installed at a later stage. When an electric actuator is fitted, a control panel must be attached next to or above the damper during mounting. For standard mounting of a pneumatic servo cylinder, use control panel type I for heights of up to < 565 or 600 and control panel type II for heights from > 634 or 800. When a thrust actuator or servo cylinder is mounted on site, it i recommended...
Open the catalog to page 12
*Spring return actuator 62 dB (A) Electric terminals 24 V AC/DC, 230 V AC OPEN - CLOSED control Electric terminals 24 V AC/DC, 230 V AC Two-point Three-point 08/10 - 13 Version: 15.01.2018 Construction subject to change.
Open the catalog to page 13
Connection diagram Pneumatic servo cylinder Legend Apt (Pa) = Pressure loss vstirn (m/s) = Intake velocity, blower stream velocity, out flow velocity, relative to B x H a (°) = Blade position Lwa[dB(A)] = A-weighted sound power level [LWA = LWA1 + KF] LWAi [dB(A)] = A-weighted sound power level, relative to 1 m2 p (kg/m3) = Density KF (-) = Correction factor Astirn (m2) = Face area H (mm) = Height B (mm) = Width Vleck (m3/h) = Leak air volume Vleck [l/s] = Leak air volume Construction subject to change.
Open the catalog to page 14All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages