08/10 - 2 Construction subject to change. Version: 17.07.2019 No return possible!
Open the catalog to page 2Multi-leaf damper HK Description Application range Multi-leaf dampers type HK are used in air-conditioning and ventilation systems as control, throttle or shut-off dampers to control pressure and volumetric flow. The flow-favouring blades are adjusted together, rotating in opposite directions, via external plastic gear wheels. The external arrangement of the gears has the advantage that, in comparison with internally arranged gears exposed to the air flow, they do not become dirty that quickly. A cover plate protects the gear wheels from outside dirt and reduces the personal accident danger during...
Open the catalog to page 3Multi-leaf damper HK model HK-P HK-U HK-K HK-...-R HK-...-L with plastic bearing with sintered bearing with brass bearing (only H = 100 available) Operating side on the right Operating side on the left Accessories - Add-on parts - Installation frame 35/35/4 with riveted wall anchors (-ER2) - Flat-steel counter frame 33/5 (-FG1) - Angular steel counter frame 30/30/3 (-WG1) - Locking device (-M001, only HK-U / HK-P), mounted to the multi-leaf damper. - Shaft design (at an extra charge, not possible for HK-K) (-W02/ -W03) - including bearing block - Electric actuator, 2/3-point - 5 Nm, 24 V AC/DC...
Open the catalog to page 4Multi-leaf damper HK Models and dimensions Dimensions HK-P (with plastic bearing) HK-U (with sintered bearing) Available sizes HK-P / HK-U Standard series of dimensions All combined lengths and heights available. Note: The dimensions w1, w2 and x are rounded values! Construction subject to change.
Open the catalog to page 5As standard, multi-leaf dampers are supplied with corner angles. The special form of the corner holes allows them to be connected to the connection systems available on the market (e.g. Metu system M 2/M 3) Shaft design (-W02/ -W03) (not possible for HK-K) Operating side left Operating side right The number of holes does not include the 4 corner holes. Number of holes B All combined lengths and heights available. Construction subject to change. The above figure shows the division of multi-leaf dampers greater than 1998 mm and 2000 mm in height. The blades in the two sections are joined by a coupling...
Open the catalog to page 6Multi-leaf damper HK Multi-leaf damper divided vertically The figure opposite shows the division of multi-leaf dampers greater than 1998 mm and 2000 mm in width. It is not possible to join the two sections. Operating side 1 x "on the left" and 1 x "on the right". All frames are supplied in primed design. Vertically and horizontally divided multi-leaf dampers The figure opposite shows the division of multi-leaf dampers greater than 1998 mm and 2000 mm in width and height. The blades in the two sections on top of each other are joined by a coupling rod. It is not possible to join the horizontally...
Open the catalog to page 7Multi-leaf damper HK Dimensions of accessories Assembly detail Installation frame (-ER2) Flat-steel counter frame (-FG1) Angular steel counter frame (-WG1) Multi-leaf dampers can be additionally fitted with: 1.) Installation frame 35/35/4 with riveted wall anchors (-ER2) 2.) Flat-steel counter frame 33/5 (-FG1) 3.) Angular steel counter frame 30/30/3 (-WG1) undrilled or drilled. All frames are supplied in primed design. Installation frame (-ER2) Bearing block A bearing block is already mounted ex-works for shaft Bearing block design (W02/W03). When a servo cylinder is mounted in factory, the...
Open the catalog to page 8Multi-leaf damper HK with pneumatic servo cylinder (not available for HK-K) H = 201-565 or H = 200-600 limit switch CLOSED OPEN Console type I (screwed-on) Electric limit switches can be installed to indicate position or to perform switching functions only available with shaft design (W02/W03)! H = 634-1998 or H = 800-2000 Installation options: - Damper position "CLOSED" 1 limit switch (-ESZ) Damper position "OPEN" 1 limit switch (-ESA) with 2 limit switches, "CLOSED" and "OPEN" (-ES2) If an electric actuator or pneumatic servo cylinder is used, the limit switches can also be installed as shown...
Open the catalog to page 9Multi-leaf damper HK Technical data Volumetric flow range Leak air volume with closed damper (HK-U/HK-P) Pressure loss and noise level Pressure loss (as a function of the blade position a) Open connection Correction factor (for flow generated noise) Construction subject to change.
Open the catalog to page 10Multi-leaf damper HK Selection actuator / servo cylinder HK-P/HK-U (with electric actuator) HK-P/HK-U with pneumatic servo cylinder The actuators E001 - E008 and E012 - E015 can be fitted with a limit switch "OPEN" or "CLOSED" or with two limit switches "CLOSED" and "OPEN". The actuators with spring return can be fitted with two limit switches "CLOSED" and "OPEN". When a pneumatic servo cylinder is mounted in factory, a bearing block is mounted on the multi-leaf damper as well by default. The electric actuator or pneumatic cylinder can also be installed at a later stage. When a thrust actuator...
Open the catalog to page 11Multi-leaf damper HK Selection Construction subject to change.
Open the catalog to page 12*Spring return actuator 62 dB (A) Electric terminals 24 V AC/DC, 230 V AC Two-point Three-point Electric terminals 24 V AC/DC, 230 V AC OPEN - CLOSED control Connection diagram Pneumatic servo cylinder Festo type DSNU-25-140-P (-P001) Festo type DSNU-40-140-P (-P002) -1 Pressure loss Intake velocity, blower stream velocity, outflow velocity, relative to B x H Blade position A-weighted sound power level [Lwa = LWA1 + KF] A-weighted sound power level, relative to 1 m2 Density Correction factor Face area Height Width Leak air volume Leak air volume Leaf area Construction subject to change.
Open the catalog to page 13Multi-leaf damper HK Order details 01 Example HK-U-0400-0201-SV-W01-R-E000-AU-NA-ER2-RB1-ESA Multi-leaf damper, rectangular design, not airtight I with sintered bearing I width 400 mm I height 201 mm I galvanised sheet steel I shaft design 50 mm | operating side on the right | without actuator, with loose locking device | fitted outside | no spring return actuator I with installation frame, with wall anchors I with frame bores on one side I with external limit switch, position "OPEN" ORDER DETAILS 01 - Type HK = Multi-leaf damper, rectangular design, not airtight 02 - Model P = with plastic bearing...
Open the catalog to page 1432 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages