07/08 - 2 Construction subject to change. Stand: 22.02.2018 No return possible!
Open the catalog to page 2Lint separator FLARE Description To separate textile fibre from the return air of clean rooms, in particular operating theatres and their adjoining rooms, a lint separator is used. The separation takes place directly at the extraction point. As a component of the ventilation installation, the separator is mounted in the exhaust air outlet flush with the operating theatre wall or in overflow openings. This protects the air-conditioning ducts and the downstream filters by separating fibre particles in the operating theatre area and allows an economic and smooth operation of the ventilation and...
Open the catalog to page 3Lint separator FLARE Models and dimensions Dimensions FLARE-...-SM-... with AK-36-...-S1 Detail X Z as-delivered condition with fitted fixing lug Z with bent fixing lug Available sizes Spigot arrangement for plenum box L - Spigot from above (-S0) - Lateral spigot (-S1, standard) - Spigot front side (-S4) Dimensions and prices for spigot from above (-S0) and spigot front side (-S4) upon request. 07/08 - 4 Construction subject to change. Stand: 22.02.2018 No return possible!
Open the catalog to page 4Mounting frames are only delivered with 4 wall anchors on special request (at an extra charge) (-ER2). Construction subject to change.
Open the catalog to page 5Lint separator FLARE Fastening methods Concealed mounting FLARE-...-VM - with 2x VM11 (1 each on H side) 225x125 / 325x125 / 425x125 / 525x125 / 625x125 / 225x225 / 325x225 / 425x225 / 525x225 / 625x225 SM mounting FLARE-...-SM - with 4 sash locks 225x125 / 225x225 / 325x325 1.) with 4 or 6 indentations for on-site slotted shallow-raised countersunk-head tapping screws DIN ISO 7051 pitch 3.9 For number and position of sash locks, see SM mounting. 07/08 - 6 Construction subject to change. Stand: 22.02.2018 No return possible!
Open the catalog to page 6Lint separator FLARE Technical data Pressure loss and noise level FLARE-...-225-125-... with AK-36-... 07/08 - 7 Construction subject to change. Stand: 22.02.2018 No return possible!
Open the catalog to page 7Lint separator FLARE FLARE-...-325-225-... with AK-36-... 07/08 - 8 Construction subject to change. Stand: 22.02.2018 No return possible!
Open the catalog to page 8Lint separator FLARE FLARE-...-425-325-... with AK-36-... 07/08 - 9 Construction subject to change. Stand: 22.02.2018 No return possible!
Open the catalog to page 9Return air volume Return air volume Pressure loss Density A-weighted sound power level Length Width approximately Construction subject to change.
Open the catalog to page 10ICHAK#Lint separator FLARE Order code FLARE 01 Sample FLARE-PS-625-125-A-9010-SM-ER0 Lint separator type FLARE I perforated sheet steel I grille length 625mm I grille height 125mm I return air I frame painted to RAL 9010 (white) I screw mounting I without mounting frame Order details 01 - Type FLARE = Rectangular lint separator 02 - Model PS = Perforated sheet steel with back-fitted wire fabric made of stainless steel 0.8 mm x 0.5 mm (standard) V2 = Stainless steel (V2A), perforated, with back-fitted wire fabric made of stainless steel 0.8 mm x 0.5 mm 03 - Length 225 = Grille length 225 mm 325...
Open the catalog to page 11Lint separator FLARE Order code AK 01 Plenum box, rectangular design I suitable for lint separator FLARE I length 425 mm I height 225 mm I standard length I with screw mounting I sheet steel painted to RAL 9010 (white) I with damper | with rubber lip seal | without box insulation | standard height of box | standard width of box I standard spigot diameter | lateral spigot Order details 01 - Plenum box AK = Plenum box, rectangular design 02 - Air diffuser (must be ordered separately) 36 = suitable for FLARE-... 03 - Length 225 = Grille length 225 mm 04 - Height 125 = Grille height 125 mm 225 =...
Open the catalog to page 12Lint separator FLARE Specification texts Lint separator for filtering textile fibre charged return air from clean rooms, consisting of a rectangular frame and a fitted, replaceable lint separator insert made of sheet steel painted to RAL 9010 (white) (-PS) or stainless steel 1.4301 (V2A) (-V2) sand silver painted (-SAND), with back-fitted wire fabric made of stainless steel 1.4301 (V2A), mesh width 0.8 mm x 0.5 mm. Fastening by means of screw mounting (-SM) or concealed mounting (-VM). For cleaning and disinfection purposes, easy to disassemble by turning the sash lock. Product: SCHAKO type FLARE-...-A-......
Open the catalog to page 1332 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages