

Catalog excerpts

TECHNICAL DOCUMENTATION EasyBus Signalling and Switching Bus System SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen
Open the catalog to page 1
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION Overview | The signalling and switching bus system SCHAKO EasyBus can be used, among other things, for activating and monitoring mechanical and electrical fire dampers with 24V DC or 230V AC spring return actuator, smoke extraction dampers, smoke detectors and volumetric flow controllers with 0(2)-10V activation or air diffusers with 2/3-point motorised drives. Properties of EasyBus Up to 128 EasyBus field modules can be connected per master unit. The total length per master is limited to 1000 m. The regulations according...
Open the catalog to page 2
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION System overview | The advantages of the flat cable system are quick and simultaneous contacting of the three conductors without requiring tools. The following figure shows the principle of this contact technology. MODULE OVERVIEW For individual areas, we are offering the following modules for signal processing and monitoring: 1 = Piercing screw 2 = Flat cable box 3 = Stranded copper wire 4 = Wire insulation 5 = Flat cable 6 = Lower part In place of the screw, penetrometers can also be used to establish contact with the...
Open the catalog to page 3
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION EasyBus - System design | EASYBUS - SYSTEM DESIGN Additional EasyBus network with 128 users maximum EASYLIGHT - SYSTEM DESIGN Connection of a PLC via Modbus RTU Protocol with RS485 or RS-232 Construction subject to change No return possible
Open the catalog to page 4
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | THE COMPONENTS IN DETAIL Module housing It is used for all modules and has proven itself already many times in building installation technology. Its closure system allows opening and closing without the need for tools. The transparent top allows LEDs and status displays to be read directly on the module without having to open the housing. Technical data Dimensions (BxHxT): Protection class: Protection type: Ambient temperature : Storage temperature: Weight: Screw connection: EasyBus motherboard...
Open the catalog to page 5
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | EasyF-ADC The EasyF-ADC module is used for connecting and controlling a 24V DC motorised actuator, for example, of a fire damper or a smoke extraction damper. When connected to a smoke extraction damper, it is mandatory that the connection line from the module to the bus line and, if necessary, the bus line itself complies with DIN 4102-12:1998-11 (in case of products with CE marking, with EN 13501-1 and EN 13501-2) of the desired functional integrity class. Moreover, the module must be...
Open the catalog to page 6
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | EasyF-VDC INCL. 2 ANALOGUE CONNECTIONS The EasyF-VDC module is used for connecting and controlling two independent steadily regulating DC drives, for example VAV (Variable Air Volume) or valves. The EasyF-VAC module is used for connecting and controlling two independent steadily regulating AC drives, for example VAV (Variable Air Volume) or valves. The two independent analogue 0-10 V input can receive the signal, for example of a CO2 sensor, a temperature sensor, etc., and be used, for example,...
Open the catalog to page 7
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | Terminals for connection to the EasyBus network 230 V AC The EasyF-VMP module is used for connecting and controlling two MP-Bus-capable drives. 2 drives can be connected to each EasyF-VMP module. Power consumption at zero load: 2.5 watts NOTE The connecting cable of a volumetric flow controller normally has a length of approx 0.9 m. The EasyF-RMM module is used for connecting the smoke detectors (RMSII-L) to the 230 V EasyBus network and is used for duct monitoring. A maximum of 2 smoke...
Open the catalog to page 8
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | The EasyF-IOM module is equipped with 4 digital inputs and potential-free changeover contact outputs, which can be switched or monitored independently of one another. The EasyF-I8M module is equipped with 8 digital inputs that can be monitored independently of one another. To the contact marked with + of the EasyF-IOM module, a 24 V DC voltage is applied and then switched via a suitable contact. Each completed actuation can then be visualised. To the contact marked with + of the EasyF-I8M...
Open the catalog to page 9
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | The EasyF-RXE module is used for connecting the EasyF-ETX (radio limit switch) to the 230 V EasyBus network. An EasyF-RXE radio receiver can be used to manage up to eight radio limit switches. Indoors a maximum distance of 30 metres from transmitter to receiver is possible, depending on local conditions. In case of power failure, end position changes can still be detected and saved for up to two hours. Power consumption at zero load: 1.4 watts Terminals for connection to the EasyBus network 230...
Open the catalog to page 10
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | Construction subject to change No return possible
Open the catalog to page 11
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | Construction subject to change No return possible
Open the catalog to page 12
EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | The master device manages up to 128 users and forms the interface with a PLC. The master executes all data traffic tasks between the EasyBus network and the control unit (PLC). The master also performs bus monitoring and system diagnostics. The filter is connected between the short-circuit, earth-fault and overload circuit breaker , the master device, and the fault-current circuit breaker. It separates the EasyBus system of a master from the lowvoltage network of the energy provider and vice...
Open the catalog to page 13All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages