EasyBus
1 /24Pages

EasyBus

EasyBus
1 /24Pages

Catalog excerpts

EasyBus-1

TECHNICAL DOCUMENTATION EasyBus Signalling and Switching Bus System SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen

 Open the catalog to page 1
EasyBus-2

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION Overview | The signalling and switching bus system SCHAKO EasyBus can be used, among other things, for activating and monitoring mechanical and electrical fire dampers with 24V DC or 230V AC spring return actuator, smoke extraction dampers, smoke detectors and volumetric flow controllers with 0(2)-10V activation or air diffusers with 2/3-point motorised drives. Properties of EasyBus Up to 128 EasyBus field modules can be connected per master unit. The total length per master is limited to 1000 m. The regulations according to...

 Open the catalog to page 2
EasyBus-3

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION System overview | The advantages of the flat cable system are quick and simultaneous contacting of the three conductors without requiring tools. The following figure shows the principle of this contact technology. MODULE OVERVIEW For individual areas, we are offering the following modules for signal processing and monitoring: 1 = Piercing screw 2 = Flat cable box 3 = Stranded copper wire 4 = Wire insulation 5 = Flat cable 6 = Lower part In place of the screw, penetrometers can also be used to establish contact with the conductor....

 Open the catalog to page 3
EasyBus-4

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION EasyBus - System design | EASYBUS - SYSTEM DESIGN Additional EasyBus network with 128 users maximum EASYLIGHT - SYSTEM DESIGN Connection of a PLC via Modbus RTU Protocol with RS485 or RS-232 Construction subject to change No return possible

 Open the catalog to page 4
EasyBus-5

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | THE COMPONENTS IN DETAIL Module housing It is used for all modules and has proven itself already many times in building installation technology. Its closure system allows opening and closing without the need for tools. The transparent top allows LEDs and status displays to be read directly on the module without having to open the housing. Technical data Dimensions (BxHxT): Protection class: Protection type: Ambient temperature : Storage temperature: Weight: Screw connection: EasyBus motherboard The...

 Open the catalog to page 5
EasyBus-6

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | EasyF-ADC The EasyF-ADC module is used for connecting and controlling a 24V DC motorised actuator, for example, of a fire damper or a smoke extraction damper. When connected to a smoke extraction damper, it is mandatory that the connection line from the module to the bus line and, if necessary, the bus line itself complies with DIN 4102-12:1998-11 (in case of products with CE marking, with EN 13501-1 and EN 13501-2) of the desired functional integrity class. Moreover, the module must be installed...

 Open the catalog to page 6
EasyBus-7

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | EasyF-VDC INCL. 2 ANALOGUE CONNECTIONS The EasyF-VDC module is used for connecting and controlling two independent steadily regulating DC drives, for example VAV (Variable Air Volume) or valves. The EasyF-VAC module is used for connecting and controlling two independent steadily regulating AC drives, for example VAV (Variable Air Volume) or valves. The two independent analogue 0-10 V input can receive the signal, for example of a CO2 sensor, a temperature sensor, etc., and be used, for example, for...

 Open the catalog to page 7
EasyBus-8

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | Terminals for connection to the EasyBus network 230 V AC The EasyF-VMP module is used for connecting and controlling two MP-Bus-capable drives. 2 drives can be connected to each EasyF-VMP module. Power consumption at zero load: 2.5 watts NOTE The connecting cable of a volumetric flow controller normally has a length of approx 0.9 m. The EasyF-RMM module is used for connecting the smoke detectors (RMSII-L) to the 230 V EasyBus network and is used for duct monitoring. A maximum of 2 smoke detectors...

 Open the catalog to page 8
EasyBus-9

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | The EasyF-IOM module is equipped with 4 digital inputs and potential-free changeover contact outputs, which can be switched or monitored independently of one another. The EasyF-I8M module is equipped with 8 digital inputs that can be monitored independently of one another. To the contact marked with + of the EasyF-IOM module, a 24 V DC voltage is applied and then switched via a suitable contact. Each completed actuation can then be visualised. To the contact marked with + of the EasyF-I8M module,...

 Open the catalog to page 9
EasyBus-10

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | The EasyF-RXE module is used for connecting the EasyF-ETX (radio limit switch) to the 230 V EasyBus network. An EasyF-RXE radio receiver can be used to manage up to eight radio limit switches. Indoors a maximum distance of 30 metres from transmitter to receiver is possible, depending on local conditions. In case of power failure, end position changes can still be detected and saved for up to two hours. Power consumption at zero load: 1.4 watts Terminals for connection to the EasyBus network 230 V...

 Open the catalog to page 10
EasyBus-11

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | Construction subject to change No return possible

 Open the catalog to page 11
EasyBus-12

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | Construction subject to change No return possible

 Open the catalog to page 12
EasyBus-13

EasyBus - Signalling and Switching Bus System TECHNICAL DOCUMENTATION The components in detail | The master device manages up to 128 users and forms the interface with a PLC. The master executes all data traffic tasks between the EasyBus network and the control unit (PLC). The master also performs bus monitoring and system diagnostics. The filter is connected between the short-circuit, earth-fault and overload circuit breaker , the master device, and the fault-current circuit breaker. It separates the EasyBus system of a master from the lowvoltage network of the energy provider and vice versa...

 Open the catalog to page 13

All SCHAKO KG catalogs and technical brochures

  1. CNVA

    32  Pages

  2. FKW (2025)

    28  Pages

  3. AUDIX

    2  Pages

  4. DISA

    4  Pages

  5. UC-OH²

    2  Pages

  6. IGA

    2  Pages

  7. CDD

    2  Pages

  8. FBS

    18  Pages

  9. PIL

    23  Pages

  10. MWS / MWK

    23  Pages

  11. ERK-SO

    43  Pages

  12. DSCXL

    17  Pages

  13. DSCPL

    16  Pages

  14. BKSYS

    18  Pages

  15. MINODSA

    6  Pages

  16. DKA

    6  Pages

  17. LAQ

    11  Pages

  18. VMPR/VMPQ

    29  Pages

  19. DSCU

    18  Pages

  20. DSCP

    15  Pages

  21. DQJP

    9  Pages

  22. BKA-EN

    79  Pages

  23. CPL

    15  Pages

  24. AUDIX®

    25  Pages

  25. VREX

    26  Pages

  26. VQEX

    17  Pages

  27. VPEX

    18  Pages

  28. SVA-FS

    11  Pages

  29. NRWG

    22  Pages

  30. COMBIDSC

    26  Pages

  31. DSC

    37  Pages

  32. DO

    10  Pages

  33. VRAQ

    46  Pages

  34. UEKU

    6  Pages

  35. UEK

    6  Pages

  36. SS-K

    6  Pages

  37. VOLKOM

    6  Pages

  38. STV

    8  Pages

  39. DQJ

    38  Pages

  40. ALAS-F 125

    6  Pages

  41. ALPETY

    16  Pages

  42. CTT

    23  Pages

  43. KWB

    19  Pages

  44. GREENKIT

    20  Pages

  45. SVA-FF

    15  Pages

  46. FKU

    31  Pages

  47. FKF

    29  Pages

  48. SGA

    5  Pages

  49. DBB

    27  Pages

  50. TVO

    8  Pages

  51. AL

    23  Pages

  52. NBS

    34  Pages

  53. MKAR_MKAQ

    13  Pages

  54. KF

    4  Pages

  55. JK

    16  Pages

  56. HK

    16  Pages

  57. FLAQ

    11  Pages

  58. FG

    14  Pages

  59. ERK-MB

    38  Pages

  60. DISA-H (2025)

    34  Pages

  61. DISA-360

    32  Pages

  62. DISA-300

    51  Pages

  63. CNV

    29  Pages

  64. BKA-UE

    35  Pages

  65. BAK-240

    16  Pages

  66. Aquaris-Silent

    38  Pages

  67. Aquaris_KWB

    20  Pages

  68. DISA-W

    43  Pages

  69. BDA

    11  Pages

  70. PILB/PILBR

    33  Pages

  71. DAV

    19  Pages

  72. 4DE

    18  Pages

  73. 4DF

    13  Pages

  74. DQC

    16  Pages

  75. DQDL

    16  Pages

  76. IDA

    21  Pages

  77. IKA

    23  Pages

  78. ZMD

    17  Pages

  79. DQF

    15  Pages

  80. DQJF

    12  Pages

  81. DQJA/DQJR

    10  Pages

  82. DQJSL

    17  Pages

  83. DQJSLC

    17  Pages

  84. DHV

    18  Pages

  85. COMBIDQJ

    11  Pages

  86. COMBIPIL

    11  Pages

  87. DSA

    15  Pages

  88. DSARR

    7  Pages

  89. QA

    30  Pages

  90. PUSH

    23  Pages

  91. WQA

    12  Pages

  92. DSX

    25  Pages

  93. DSX-XXL

    23  Pages

  94. AUDIX®-AW

    20  Pages

  95. AUDIX®-ÜSG

    13  Pages

  96. DSX-XXL-W

    25  Pages

  97. SIA

    7  Pages

  98. SAR/SAQ/SARP

    13  Pages

  99. WDA

    32  Pages

  100. BSG

    19  Pages

  101. KG

    19  Pages

  102. IB-Q

    21  Pages

  103. IB-R

    15  Pages

  104. LK

    12  Pages

  105. PA

    32  Pages

  106. DBBR

    6  Pages

  107. KGRR

    17  Pages

  108. DBBRR

    11  Pages

  109. WGARR

    7  Pages

  110. WGA

    29  Pages

  111. ALA

    4  Pages

  112. ALA-R

    4  Pages

  113. ALA-SO

    4  Pages

  114. ALAS

    10  Pages

  115. ALAS-P

    5  Pages

  116. DKAPPs

    6  Pages

  117. EBE/EBP

    52  Pages

  118. DKG

    6  Pages

  119. MBE/MBP

    27  Pages

  120. PIANO

    27  Pages

  121. VAS

    26  Pages

  122. VAQS

    19  Pages

  123. VARS

    26  Pages

  124. VRAPPs

    20  Pages

  125. VRAR

    52  Pages

  126. MAK

    15  Pages

  127. RS-F

    7  Pages

  128. RS

    15  Pages

  129. DISA-Family

    4  Pages

  130. RMS

    11  Pages

  131. TSR

    5  Pages

  132. VLV

    31  Pages

  133. MBM

    10  Pages

  134. LL

    7  Pages

  135. RR-Complete

    41  Pages

  136. MINODSX

    6  Pages

  137. SPB

    10  Pages

  138. DISA-H

    34  Pages

  139. AQUARIS SILENT

    38  Pages

  140. NBS

    24  Pages

  141. JK-LP/JK-LU

    15  Pages

  142. HKP / HKU

    16  Pages

  143. FKW

    16  Pages

  144. FLARE

    13  Pages

  145. RF

    7  Pages

  146. KGF

    9  Pages

  147. SVA-FF

    8  Pages

  148. BKA-Ü

    35  Pages

  149. BSK-RPR

    60  Pages

  150. BKP-EN

    40  Pages

  151. BAK-240

    6  Pages

  152. BAK-250

    14  Pages

Archived catalogs

  1. DISA-B

    32  Pages

  2. DISA-601

    41  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.