Catalog excerpts

04/04 - 2 Construction subject to change. Version: 13.05.2020 No return possible!
Open the catalog to page 2
Ceiling Slot Diffuser DSX-XXL model DSX-XXL DSX-XXL-S DSX-XXL-P DSX-XXL-PA DSX-XXL-PB DSX-XXL-...-1/2/3/4 DSX-XXL-...-Z DSX-XXL-...-A DSX-XXL-...-...-L II R DSX-XXL-...-...-L II L DSX-XXL-...-...-L III Description The ceiling slot diffuser type DSX-XXL-S is suitable for installation in closed ceiling systems, in rooms of heights 2.6 to 4 m. In panelled ceilings, the use of the black (RAL 9005) air guide element allows an approximately invisible installation of the slot diffuser. The versions DSX-XXL-P, DSX-XXL-PA and DSX-XXL-PB with support profile are suitable for installation of the cover...
Open the catalog to page 3
Ceiling Slot Diffuser DSX-XXL Accessories Plenum box (-ASK) - Galvanised sheet steel, with lateral connection spigot and fixing lugs. Damper (-DK) - Damper made of galvanised sheet steel - Damper fastening made of plastic Corner angle 90° (-EW) - supplied loose as standard - extruded aluminium profile (same colour as DSX-XXL) M4 riveting nut - at an extra charge End piece (pair) (-ES) - supplied unassembled as standard. If there are order details regarding fitting, mounting will take place at the factory. - for DSX-XXL-S (-ES1), aluminium painted to RAL 9005 (black) or RAL 9010 (white). -...
Open the catalog to page 4
Ceiling Slot Diffuser DSX-XXL DSX-XXL-...-1 to 4 L=500-1500, one-way throw (-LIIL / -LIIR) V t' t' t V t' )=P=P=P All air guide elements are adjusted in one direction. In each case, the complete slot rows must be set to one direction. In each case, 2 air guide element rows must be installed on the right, 2 air guide element rows on the left, etc. With L=500 and L=1500, the last air guide element row must be used opposite to the previous one. 'i'p p it p p m Attention: In each case, 2 complete slot rows must each be set to one direction. In the return air model, the air throw pattern -LIII...
Open the catalog to page 5
Ceiling Slot Diffuser DSX-XXL Dimensions DSX-XXL-S without support profile For installation in closed ceiling systems or for invisible installation in the joint of panelled ceilings. DSX-XXL-S-1 DSX-XXL-P, with support profile For installation in ceiling panels, suitable for installation in closed ceiling systems. DSX-XXL-P-1 DSX-XXL-PA, with support profile For installation in closed ceiling systems DSX-XXL-PA-1 DSX-XXL-PB, with support profile For installation in ceiling panels, suitable for installation in closed ceiling systems. DSX-XXL-PB-1 1.) anodised model 2.) painted model 04/04 -...
Open the catalog to page 6
Ceiling Slot Diffuser DSX-XXL Dimensions of accessories Plenum box type ASK for DSX-XXL-... Available sizes View A with 1 spigot with 2 spigots Detail X / diffuser mounting Standard: at an extra charge: To facilitate ceiling mounting, the plenum boxes can be provided with an M4 riveting nut. When delivered without plenum box, mounting must be done on-site. Rubber lip seal (-GD) Detail Y Construction subject to change.
Open the catalog to page 7
Ceiling Slot Diffuser DSX-XXL Detail a, without end pieces DSX-XXL-S / DSX-XXL-PA DSX-XXL-P / DSX-XXL-PB When the ceiling slot diffuser type DSX-XXL is designed as a band > 2000 mm, the total length BL is assembled from standard lengths L = 1500 mm. The difference pieces <1500 mm to >400 mm are fitted with a plenum box. The difference pieces <400 mm are supplied as dummy pieces without plenum box. A different band division is possible after consultation and when required by the customer. Individual sections are connected by using double blades. 04/04 - 8 Version: 13.05.2020 Construction...
Open the catalog to page 8
Connection elements for band design (supplied loose as standard) active - active Connection element 1 not possible when diffuser is suspended with riveting nut and band design is used. active - passive passive - passive Construction subject to change.
Open the catalog to page 9
Mounting bracket (pair) (-BW) for operation with overflow air Construction subject to change.
Open the catalog to page 10
Ceiling Slot Diffuser DSX-XXLBand design for operation with overflow air or dummy plates In the band design for operation with overflow air or dummy plates, two additional fishplates are supplied loose, thus only requiring two threaded bars on-site for suspension. End piece (-ES1 / -ES2 / -ES3) To give the impression of a surrounding frame, side end pieces can be installed (for an additional charge). These end pieces are supplied loose as standard. If there are order details regarding fitting, mounting will take place at the factory. for DSX-XXL-S (-ES1) Construction subject to change.
Open the catalog to page 11
Corner angles can only be produced as dummy pieces, i.e., without a plenum box. The corner angle has a 90° angle and is 300 mm long. Other angles are available on request The dummy plate is painted in the colour RAL 9005 (black) or RAL 9010 (white). The corner brackets are supplied loose as standard. Construction subject to change.
Open the catalog to page 12
Ceiling Slot Diffuser DSX-XXL Fastening methods Clamp fastening for DSX-XXL-P und DSX-XXL-PB in mounting position Concealed mounting (-VM) with plenum box DSX-XXL-...-1 to DSX-XXL-...-4 (1- to 4-slot) Installation Fitting to air-handling lights Mounting instructions As standard, the clamp straps are delivered loose. Take out the air guide elements at the ends. Fasten the clamp strap with the screw such that it is positioned in the direction of the slot diffuser (see installation position). Then introduce the slot diffuser into the pressure ceiling. Then rotate the clamp strap by about 90°...
Open the catalog to page 13
Ceiling Slot Diffuser DSX-XXL Technical data Pressure loss and noise level DSX-XXL-...1 with ASK L=1000 (supply air) 100% = Damper OPEN 04/04 - 14 Construction subject to change. Version: 13.05.2020 No return possible!
Open the catalog to page 14
Ceiling Slot Diffuser DSX-XXL DSX-XXL-...1 with ASK L=1000 (return air) 04/04 - 15 Construction subject to change. Version: 13.05.2020 No return possible!
Open the catalog to page 15
Maximum end velocity of jet DSX-XXL-...-1 L=1000, one-way throw Critical throw Induction ratios and temperature ratios DSX-XXL-...-1 DSX-XXL-...-2 Construction subject to change.
Open the catalog to page 16
Ceiling Slot Diffuser DSX-XXL Legend VZU (m3/h S) = Supply air volume per slot Supply air volume per slot Return air volume per slot Return air volume per slot Pressure loss Density A-weighted sound power level Critical throw Temperature difference between supply air and room temperature (DTo = tZu - tR) Maximum end velocity of jet total air jet volume at point x Temperature ratio (TV = DTx / DTo) Induction ratio (i = Vx / Vzu) horizontal throw vertical throw Supply air temperature Room temperature Length of box Width of box height of a plenum box Total height Length Temperature difference...
Open the catalog to page 17All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCXL
17 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages