Wall Slot Diffuser DSX-XXL-W
Open the catalog to page 104/05 - 2 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 2Wall Slot Diffuser DSX-XXL-W Model DSX-XXL-W DSX-XXL-W-S DSX-XXL-W-P DSX-XXL-W-PA DSX-XXL-W-PB DSX-XXL-W-...-1/2 DSX-XXL-W-...-Z DSX-XXL-W-...-A 6Description The architecturally attractive wall slot diffuser type DSX-XXL-W-S is suitable for installation in or at wall systems. The models DSX-XXL-W-P, DSX-XXL-W-PA and DSX-XXL-W-PB with a continuous frame are suitable for achieving a good and clean finish when installed in a wall. The high induction ensures fast reduction of the air outflow velocity and of the temperature difference in cooling mode. The air outflow direction is set in-factory to...
Open the catalog to page 3Wall Slot Diffuser DSX-XXL-W Fastening permanent connection - Standard for models DSX-XXL-W-... Concealed mounting (-VM) - Standard for band design with plenum box (-ASK) - available for single diffusers with plenum box (-ASK) Construction subject to change.
Open the catalog to page 4Wall Slot Diffuser DSX-XXL-W Models and dimensions Air throw pattern Air guide element position diagonally upwards (-LV) for supply and return air models Dimensions DSX-XXL-W-P, with frame profile DSX-XXL-W-S: with narrow frame profile DSX-XXL-W-PB - with wide frame profile DSX-XXL-W-PA: with U-frame profile 1.) anodised model 2.) painted model 04/05 - 5 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 5Wall Slot Diffuser DSX-XXL-W Dimensions of accessories Plenum box type ASK-W for DSX-XXL-W-... Available sizes Section A-A / Diffuser mounting Standard: at an extra charge: Insulation for plenum box internal (-li) = Height of plenum box = Total height View B (drawn rotated by 90°) with 1 connection spigot with 2 spigots To facilitate ceiling mounting, the plenum boxes can be provided with an M4 riveting nut. When delivered without plenum box, mounting must be done onsite. Rubber lip seal (-GD) Detail Y Damper (-DK) for plenum box type ASK-W Cable-operated adjustment 04/05 - 6 Construction subject...
Open the catalog to page 6Wall Slot Diffuser DSX-XXL-W DL = Difference distance BL = Length of band L = 500/1000/1500 mm Detail a, without end pieces DSX-XXL-W-S / DSX-XXL-W-PADSX-XXL-W-P / DSX-XXL-W-PB DL = Difference distance BL = Length of band L = 500/1000/1500 mm Detail b, with end pieces DSX-XXL-W-S (-ES1) DSX-XXL-W-P (-ES2) / DSX-XXL-W-PB (-ES3) When the ceiling slot diffuser type DSX-XXL is designed as a band > 2000 mm, the total length BL is assembled from standard lengths L = 1500 mm. The difference pieces <1500 mm to >400 mm can be fitted with a plenum box. The difference pieces <400 mm are supplied as dummy...
Open the catalog to page 7Wall Slot Diffuser DSX-XXL-W End piece (-ES1 / -ES2 / -ES3) To give the impression of a surrounding frame, side end pieces can be installed (for an additional charge). These end pieces are supplied loose as standard. If there are order details regarding fitting, mounting will take place at the factory. for DSX-XXL-W-S (-ES1) for DSX-XXL-W-P (-ES2) for DSX-XXL-W-PB (-ES3) Please specify when ordering whether end pieces are to be fitted on both sides of the diffuser or on the left or right side. Construction subject to change.
Open the catalog to page 8Wall Slot Diffuser DSX-XXL-W Connection element for band design (supplied loose as standard) active - active Mounting handle for double blade Detail of connection element 3 Double blade active - passive Fastening screw: Torx screw M4 DIN 7991-TX passive - passive Fastening screw: Torx screw M4 DIN 7991-TX 04/05 - 9 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 9Wall Slot Diffuser DSX-XXL-W Dummy piece (-BS) DSX-XXL-W-P-1 Mounting bracket (pair) (-BW) for operation with overflow air DSX-XXL-W-P-1 Arrangement of the mounting holes in the dummy plate DSX-XXL-W-...-1 (1-slot) with 2 mounting holes Arrangement of the mounting holes DSX-XXL-W-...-1 (1-slot) with 2 mounting holes DSX-XXL-W-...-2 (2-slot) with 4 mounting holes DSX-XXL-W-...-2 (2-slot) with 4 mounting holes In the dummy design, no operation with overflow air is possible since the slot diffuser is completely closed at the back. 04/05 - 10 Construction subject to change. Version: 08.02.2019 No...
Open the catalog to page 10Wall Slot Diffuser DSX-XXL-WBand design for operation with overflow air or dummy plates In the band design for operation with overflow air or dummy plates, two additional fishplates are supplied loose, thus only requiring two threaded bars on-site for suspension. Fastening methods Concealed mounting (-VM) with plenum box DSX-XXL-W...-1 and DSX-XXL-W-...2 (1- and 2-slot) On request, the plenum box can be mounted rotated. This must be specified when ordering the plenum box. The clearance between ceiling and upper edge of the diffuser must not exceed 0.5 m, otherwise no coanda effect is achieved!...
Open the catalog to page 11Wall Slot Diffuser DSX-XXL-W Technical data Pressure loss and noise level DSX-XXL-W-...1 L=400 (supply air) 100% = Damper OPEN 04/05 - 12 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 12Wall Slot Diffuser DSX-XXL-W DSX-XXL-W-...1 L=600 (supply air) 04/05 - 13 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 13Wall Slot Diffuser DSX-XXL-W DSX-XXL-W-...1 L=1000 (supply air) 04/05 - 14 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 14Wall Slot Diffuser DSX-XXL-W DSX-XXL-W-...1 L=500 (return air) 100% = Damper OPEN 04/05 - 15 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 15Wall Slot Diffuser DSX-XXL-W DSX-XXL-W-...1 L=800 (return air) 04/05 - 16 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 16Wall Slot Diffuser DSX-XXL-W Maximum end velocity of jet DSX-XXL-W-...-1 L=400 Correction factor for DSX-XXL-W-...-2: vmax × 1.33 04/05 - 17 Construction subject to change. Version: 08.02.2019 No return possible!
Open the catalog to page 17Calculation of the maximum throw distance in cooling mode DSX-XXL-W-...-1 L=400 x = xkr x 2, 66 Correction factor for DSX-XXL-W-...-2: xkr x 1.17 04/05 - 18 Version: 08.02.2019 Construction subject to change. No return possible!
Open the catalog to page 1832 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages