Catalog excerpts

Technical documentation DSCXL Slot diffuser for plasterboard ceilings SCHAKO | Ferdinand Schad KG Steigstrasse 25-27 D-78600 Kolbingen
Open the catalog to page 1
DSCXL TECHNICAL DOCUMENTATION Function and use | Quick selection with plenum box, supply air model (with blade) Values for length L = 1000 mm Blade position (-L) one-way horizontal left throw The slot diffuser type DSCXL is suitable for use in rooms with a height between 2.6 m and 4 m for direct installation in plasterboard ceilings or ceiling cavities (pressure ceilings). The special shape of the frame profile allows good installation in the plasterboard ceiling. Frame profiles are fitted with bores to allow them to be connected to the plasterboard ceiling using screws. The air deflection...
Open the catalog to page 2
DSCXL TECHNICAL DOCUMENTATION Processing | Accessories PROCESSING Frame surface -- Frame profile PLASTER made of natural aluminium (-ALRO). Blade colour -- Painted aluminium: - Colour similar to RAL 9011 (graphite black, standard) (-L9011). - Colour similar to RAL 9010 (white) (-L9010). - RAL colour can be freely selected (-Lxxxx) -- For return air without blade (-00000), with perforated plate made of sheet steel painted to RAL 9011 (graphite black), as cover screen. Cover plate -- For models with dummy element -- Sheet steel painted to the RAL colour of the blade. End piece -- Mounted ex...
Open the catalog to page 3
TECHNICAL DOCUMENTATION Dimensions | Available lengths for the slot diffuser Single design (-N) DSCXL-1-Z (supply air, 1-slot) - Length 1000 mm (length of box KL = 1040 mm) (-01000-N) - Length 1500 mm (length of box KL = 1540 mm) (-01500-N) - Length in mm, can be freely selected (length of box KL = L + 40 mm), possible length L <1000 mm to ≥400 mm) (-xxxxxN) Band design (-B) - Length in mm, can be freely selected, as band (total length of box GKL = BL + 40 mm) (-xxxxx-B) (Available lengths according to SCHAKO standard) DSCXL-1-A (return air, 1-slot) Available lengths according to SCHAKO...
Open the catalog to page 4
TECHNICAL DOCUMENTATION Dimensions | Slot diffuser connection in band design Slot diffuser - slot diffuser / Slot diffuser - corner angle With fishplates: supplied loose (2x for each connection) Construction subject to change No return possible
Open the catalog to page 5
DSCXL TECHNICAL DOCUMENTATION Dimensions of accessories | Plenum box (-AKXL-27) Plenum box (-AKXL-27-1-N-...) single design Mounting of box without diffuser mounting (-OM) Plenum box (-AKXL-27-1-B-...) in band design Mounting of box without diffuser mounting (-OM) For the plenum box in band design (BL= >1500 mm), the total length of box (GKL) is divided into standard lengths KL=1000 mm and a difference in length of box (DKL) <1000 mm. A difference in length of box <120 mm is not possible. Box section and box front side fastening as well as a connecting angle must be provided on site....
Open the catalog to page 6
TECHNICAL DOCUMENTATION Dimensions of accessories | Spigot position Spigot position in the plenum box, single design: S0 = 2 spigots from above, in the sheet housing case. S1 = 2 lateral spigots, in the sheet housing case. S4 = 2 spigots front side at the front side of the housing (one left + one right). Spigot position in the plenum box, band design: S0 = for standard length: 2 spigots from above, in the sheet housing case for difference in length: 1 or 2 spigots from above, in the sheet housing case. S1 = for standard length: 2 lateral spigots, in the sheet housing case for difference in...
Open the catalog to page 7
DSCXL TECHNICAL DOCUMENTATION Dimensions of accessories | Fastening methods Corner angle 90° (-EW-27-...-090-...) Corner angles can only be produced as dummy pieces, i.e., without a plenum box. The corner angles are installed in the ceiling by means of screw mounting with mounting bracket. The diffuser is connected to the corner angle by means of fishplates (see page 5). 4 fishplates are included in delivery (2 for each connection). They are supplied loose. Standard left-side length (a) L=250 (-000) / right-side length (b) L=250 (-000). Other side lengths (a/b) are available upon request...
Open the catalog to page 8
ASSEMBLY DETAIL DSCXL TECHNICAL DOCUMENTATION Assembly detail | Installation instructions With mounting bracket: 4 mounting brackets: 6 mounting brackets: 8 mounting brackets: 10 mounting brackets: L = length (for single / band design) DL = difference in length (for band design) The mounting bracket is supplied loose and unbent. It will then be canted on site in order to fit the required ceiling depth. The single bore serves here as a marking for the ceiling depth T=12.5. The installation of the slot diffusers DSCP / DSCPL / DSCXL is identical (see installation instructions "DSCP / DSCPL /...
Open the catalog to page 9
TECHNICAL DOCUMENTATION Technical data | TECHNICAL DATA Pressure loss and noise level DSCXL-Z-1-…-01000-… (L = 1000 mm, supply air, without plenum box) (L = 1000 mm, supply air, with plenum box, with damper) (L = 1000 mm, return air, without plenum box) (L = 1000 mm, return air, with plenum box, with damper) Construction subject to change No return possible
Open the catalog to page 10
TECHNICAL DOCUMENTATION Technical data | Temperature and induction ratios DSCXL-Z-1-…-01000-…-AKXL, with coanda effect DSCXL-Z-1-…-01000-…-AKXL, with coanda effect (L = 1000 mm, supply air, with plenum box) (L = 1000 mm, supply air, with plenum box) Critical throw DSCXL-Z-1-…-01000-…-AKXL, with coanda effect (L = 1000 mm, supply air, with plenum box) Construction subject to change No return possible
Open the catalog to page 11
DSCXL TECHNICAL DOCUMENTATION Legend |LEGEND EOB (mm) EOL (mm) GH (mm) i (-) KB (mm) KF (-) KH (mm) L (mm) Lw (dB) Lwa [dB(A)] fm (Hz) Vmax (m/s) Vmittel (m/s) Vzu (m3/h) [l/s] Vab (m3/h) [l/s] Vx (m3/h) [l/s] x (m) y (m) x+y (m) Xkr (m) Apt (Pa) TV (-) ATo (K) air ATok (K) Installation opening width Installation opening width total height induction ratio (i = Vx / Vzu) Width of box Correction factor Height of box length sound power level (Wref = 1 pW) A-weighted sound power level (Wref = 1 pW) Octave band centre frequency maximum velocity of jet average end velocity of jet (vmittel = vmax...
Open the catalog to page 12All SCHAKO KG catalogs and technical brochures
-
CNVA
32 Pages
-
KGF Compact Filter Grille
9 Pages
-
AUDIX
2 Pages
-
DISA
4 Pages
-
UC-OH²
2 Pages
-
IGA
2 Pages
-
CDD
2 Pages
-
FBS
18 Pages
-
MINOPAB
6 Pages
-
PIL
23 Pages
-
MWS / MWK
23 Pages
-
ERK-SO
43 Pages
-
BKSYS
18 Pages
-
MINODSA
6 Pages
-
DKA
6 Pages
-
LAQ
11 Pages
-
VMPR/VMPQ
29 Pages
-
BKA-EN
79 Pages
-
CPL
15 Pages
-
AUDIX®
25 Pages
-
VREX
26 Pages
-
VQEX
17 Pages
-
VPEX
18 Pages
-
SVA-FS
11 Pages
-
NRWG
22 Pages
-
COMBIDSC
26 Pages
-
DSCU
18 Pages
-
DSCPL
16 Pages
-
DSCP
15 Pages
-
DSC
37 Pages
-
DO
10 Pages
-
VRAQ
46 Pages
-
UEKU
6 Pages
-
UEK
6 Pages
-
SS-K
6 Pages
-
DQJP
9 Pages
-
VOLKOM
6 Pages
-
DQJ
38 Pages
-
ALPETY
16 Pages
-
CTT
23 Pages
-
STV
8 Pages
-
KWB
19 Pages
-
GREENKIT
20 Pages
-
FKU
31 Pages
-
FKF
29 Pages
-
SGA
5 Pages
-
DBB
27 Pages
-
TVO
8 Pages
-
AL
23 Pages
-
SVA-FF
15 Pages
-
RF Return air filter grille
7 Pages
-
NBS
34 Pages
-
MKAR_MKAQ
13 Pages
-
KF
4 Pages
-
JK
16 Pages
-
HK
16 Pages
-
Lint Separator FLARE
13 Pages
-
FLAQ
11 Pages
-
FKW
28 Pages
-
FG
14 Pages
-
ERK-MB
38 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
CNV
29 Pages
-
BKP-EN Fire damper
40 Pages
-
BKA-UE
35 Pages
-
BAK-250 Fire protection unit
17 Pages
-
BAK-240
16 Pages
-
Aquaris-Silent
38 Pages
-
Aquaris_KWB
20 Pages
-
DISA-W
43 Pages
-
PILB/PILBR
33 Pages
-
DAV
19 Pages
-
4DE
18 Pages
-
4DF
13 Pages
-
DQC
16 Pages
-
DQDL
16 Pages
-
IDA
21 Pages
-
IKA
23 Pages
-
ZMD
17 Pages
-
DQF
15 Pages
-
DQJF
12 Pages
-
DQJA/DQJR
10 Pages
-
DQJSL
17 Pages
-
DQJSLC
17 Pages
-
DHV
18 Pages
-
DSARR
7 Pages
-
QA
30 Pages
-
PUSH
23 Pages
-
WQA
12 Pages
-
DSX-XXL
23 Pages
-
AUDIX®-ÜSG
13 Pages
-
SIA
7 Pages
-
SAR/SAQ/SARP
13 Pages
-
WDA
32 Pages
-
KGRR
17 Pages
-
DBBRR
11 Pages
-
WGARR
7 Pages
-
WGA
29 Pages
-
DKAPPs
6 Pages
-
EBE/EBP
52 Pages
-
VRAPPs
20 Pages
-
VRAR
52 Pages
-
MAK
15 Pages
-
DISA-Family
4 Pages
-
RMS
11 Pages
-
EasyBus
24 Pages
-
TSR
5 Pages
-
RS-F
7 Pages
-
RS
15 Pages
-
VLV
31 Pages
-
VARS
26 Pages
-
VAQS
19 Pages
-
VAS
26 Pages
-
PIANO
27 Pages
-
MBM
10 Pages
-
MBE/MBP
27 Pages
-
DKG
6 Pages
-
ALAS-P
5 Pages
-
ALAS-F 125
6 Pages
-
ALAS
10 Pages
-
ALA-SO
4 Pages
-
ALA-R
4 Pages
-
ALA
4 Pages
-
LL
7 Pages
-
RR-Complete
41 Pages
-
DBBR
6 Pages
-
PA
32 Pages
-
LK
12 Pages
-
IB-R
15 Pages
-
IB-Q
21 Pages
-
KG
19 Pages
-
BSG
19 Pages
-
DSX-XXL-W
25 Pages
-
AUDIX®-AW
20 Pages
-
DSX
25 Pages
-
MINODSX
6 Pages
-
MINODSA
6 Pages
-
DSA
15 Pages
-
COMBIPIL
11 Pages
-
COMBIDQJ
11 Pages
-
MINOPAB
6 Pages
-
BDA
11 Pages
-
SPB
10 Pages
-
CULTRA-Studioline
24 Pages
-
DISA-H
34 Pages
-
DISA-360
32 Pages
-
DISA-300
51 Pages
-
AQUARIS SILENT
38 Pages
-
NBS
24 Pages
-
CNV
29 Pages
-
CNVA
32 Pages
-
JK-LP/JK-LU
15 Pages
-
HKP / HKU
16 Pages
-
FKW
16 Pages
-
FLARE
13 Pages
-
RF
7 Pages
-
KGF
9 Pages
-
SVA-FF
8 Pages
-
BKA-Ü
35 Pages
-
BSK-RPR
60 Pages
-
BKP-EN
40 Pages
-
BAK-240
6 Pages
-
BAK-250
14 Pages
-
KF
4 Pages