Technical documentation SCHAKO | Ferdinand Schad KG Steigstrasse 25-27 D-78600 Kolbingen
Open the catalog to page 1DSCP TECHNICAL DOCUMENTATION Function and use I Models FUNCTION AND USE The curved ceiling slot diffuser type DSCP is suitable for use in rooms with a height between 2.6 m and 4 m for direct installation in plasterboard ceilings or ceiling cavities (pressure ceilings). The special shape of the frame profile allows good installation in the plasterboard ceiling. Frame profiles are fitted with bores to allow them to be connected to the plasterboard ceiling using screws. The air deflection blades adjustable from below allow a variety of throw adjustment options. In cooling mode, a one- or twoway...
Open the catalog to page 2DSCP TECHNICAL DOCUMENTATION Blade position for air jet I Processing BLADE POSITION FOR AIR JET Blade position (-V) with vertical throw Blade position (-B) with horizontal two-way throw Blade position (-L) with horizontal one-way throw toward the inside Blade position (-R) with horizontal one-way throw toward the outside With the blade positions (-L) and (-B), the concentric air throw toward the inside may result in greater velocities and turbulence. Schematic diagram of a curved shape With blade positions (-L) and (-B), the concentric air throw toward the inside may result in greater velocities...
Open the catalog to page 3DSCP TECHNICAL DOCUMENTATION Accessories I ACCESSORIES Dummy piece (-BS0 / -BS1) -- Without dummy piece (-BS0). -- With dummy piece (-BS1): - Made of sheet steel painted to RAL 9005 (black). - Only possible without plenum box and hit-and-miss damper. Plenum box (-AKCP) -- Model (number of slots): - 1-slot (-1) - 2-slot(-2) -- Single / band design: - Single design (-N, curved length of box max. 1540 mm) - Band design (-B, curved length distribution according to SCHAKO standard lengths for band design) -- Curved length: - 1000 mm (-01000) - 1500 mm (-01500) - Length in mm, can be freely selected...
Open the catalog to page 4TECHNICAL DOCUMENTATION Dimensions I The radius R is always specified in the centre of the slot diffuser. R ≥ 2,000 (1- / 2-slot). Installation opening Curved length distribution for slot diffuser Single design (-N) - Curved length BoL= 1000 mm (-01000-N) (Curved length of box KBoL=1040 mm) (-01000-N) - Curved length BoL= 1500 mm (-01500-N) (Curved length of box KBoL=1540 mm) - Curved length in mm, can be freely selected (-xxxxx-N) (Curved length of box KBoL = BoL + 40 mm), curved length BoL <1000 mm to ≥400 mm can be fitted with plenum box) Band design (-B) - Curved length in mm, can be freely...
Open the catalog to page 5TECHNICAL DOCUMENTATION Dimensions of accessories I End piece (-EB) DIMENSIONS OF ACCESSORIES End piece Plenum box (-AKCP) Spigot position S0 = spigot from above S1 = inner lateral spigot (standard) S2 = outer lateral spigot End piece End pieces are mounted ex works on the slot diffuser, as plastering edge for elegant filling. In the single design, the end pieces are fixed to the left and right front side of the slot diffuser. In the band design, the end piece is mounted to the left side of the section and to the right side of the difference length as a standard. Plasterboard ceiling For models...
Open the catalog to page 6PLENUM BOX IN SINGLE DESIGN DSCP TECHNICAL DOCUMENTATION Dimensions of accessories I End piece (-EB) With outer lateral spigot (-S2) DSCP-...-AKCP-...-S2 Mounting of box without diffuser mounting (-OM) With spigot from above (-S0) DSCP-...-AKCP-...-S0 N) Available sizes for plenum box The plenum box AKCP is manufactured as standard in the plenum curved lengths KBoL = 1,040 mm or 1,540 mm. The radius R is always specified in the centre of the slot diffuser or of the plenum box. R > 2000 (1- / 2-slot). Minimum height of box KHS = spigot diameter + 65 mm. Intermediate curved lengths and other spigot...
Open the catalog to page 7Plenum box mounting View X DSCP TECHNICAL DOCUMENTATION Dimensions of accessories I End piece (-EB) with cable-operated adjustment As-delivered condition with fitted fixing lues On-site with bent fixing lugs Fastening details For mounting, the plenum box is provided with fixing holes. A permanent connection to the plasterboard ceiling via 0 3.2 bores is also possible. In this case, the plenum box must be additionally decoupled from the plasterboard ceiling using vibration dampening material. A suitable filling compound must be provided on site. Insulation (-Ia), for AKCP 1.) Fastening on site...
Open the catalog to page 8TECHNICAL DOCUMENTATION Dimensions of accessories I End piece (-EB) Dummy piece (-BS0 / -BS1) Only possible without plenum box. Models: -BS0: without dummy piece. -BS1: with dummy piece made of sheet steel painted to RAL 9005 (black). Dummy piece 1.) Dummy piece EÖB = installation opening width BoL = curved length of diffuser Construction subject to change No return possible
Open the catalog to page 9DSCP TECHNICAL DOCUMENTATION Plenum box in band design I PLENUM BOX IN BAND DESIGN Plenum box suspension for band design Plenum box (-AKCP-...-N-...) Mounting of box without diffuser mounting (-OM) When the plenum box is designed as a band (BoL= >1500 mm), the total curved length of the box BKBoL is divided into standard curved lengths KBoL=1000 mm and into a difference in curved length DKBoL <1000 mm. A difference in curved length <120 mm is not possible. Box section and box front side fastening as well as a connecting angle must be provided on site. The curved length refers to the middle of...
Open the catalog to page 10TECHNICAL DOCUMENTATION Fastening methods I Assembly detail FASTENING METHODS ASSEMBLY DETAIL Screw mounting (-SM, standard) With mounting bracket: Arrangement, number and size of the bores are the same for 1- and 2-slot models. For fastening with screw mounting (-SM, standard) Mounting bracket 1.) Indentation ISO 15065-4 2.) Dry wall screw 3.5x35, use according to DIN EN 14566 on site 3.) Mounting bracket BoL= 1,000 / with 8 indentations for SM mounting Number of mounting brackets (mounting help) 4 Mounting brackets: BoL = ≤500 6 Mounting brackets: BoL = >500 to ≤750 8 Mounting brackets: BoL...
Open the catalog to page 11DSCP TECHNICAL DOCUMENTATION Installation instructions I Legend INSTALLATION INSTRUCTIONS KBoL DKBoL BKBoL R KHS GH KB EOB T S 0D TS ES BoL DBoL EOBoL BBoL EOBBoL The installation of the slot diffusers DSCP / DSCPL / DSCXL is identical (see installation instructions "DSCP / DSCPL / DSCXL installation in plasterboard ceilings") See video on YouTube: https://www.youtube.com/icFsmPI0D18 radius height of plenum box total height width of box installation opening width depth of plasterboard ceiling thickness of filling compound diameter section end piece curved length of diffuser difference in curved...
Open the catalog to page 1232 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages