
Ceiling swirl diffuserDQJSL Ferdinand Schad KG SteigstraBe 25-27 D-78600 Kolbingen Telefon 0 74 63 - 980 - 0 Telefax 0 74 63 - 980 - 200 [email protected] www.schako.de
Open the catalog to page 105/05 - 2 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 2Ceiling swirl diffuser DQJSL Description The ceiling swirl diffuser DQJSL-... is suitable in particular for use in rooms up to a height of 4 m. The blades can be adjusted to achieve a horizontal as well as a vertical throw pattern. This swirl diffusers ensure optimal air distribution in heating and cooling. Individual areas can be shielded by setting the blades to a certain position. This may become necessary if obstacles obstruct the air flow. The adjustable blades have the shape of support profiles. The air guiding blades are aerodynamic thus giving the diffuser its low noise qualities and...
Open the catalog to page 3Ceiling swirl diffuser DQJSL Construction Faceplate - Sheet steel painted to RAL 9010 (white) - Sheet steel painted to a different RAL colour (at an extra charge) Blades - Plastic, similar to RAL colour 9010 (white (-LW9010)) or RAL 9005 (black (-LS9005)) - Aluminium painted to the RAL colour of the faceplate (subsequent adjustment of blades not possible (-ALxxxx)) Accessories Plenum box (SK-R-13-...) - Galvanised sheet steel, with integrated perforated straight-ener (supply air model only) and fixing lugs. Damper (-DK1) - Damper made of galvanised sheet steel - Damper fastening made of plastic...
Open the catalog to page 4Ceiling swirl diffuser DQJSL Models and dimensions Air throw pattern Blade setting options "increased" horizontal multi-directional throw (-A) - all blades in position 2 "high-induction" horizontal multi-directional throw (-B) - blades in positions 1+2 preset as standard vertical air throw (-V) - all blades in position 1. Highly inductive throw is preset in the factory. DQJSL-...-125-... only available with vertical or increased horizontal multi-directional throw. 05/05 - 5 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 5Ceiling swirl diffuser DQJSL Dimensions DQJSL-Z-... mit SK-R-13-Z-... (for supply air) Available sizes Spigot position KHS= standard height of plenum box Special height of plenum box = 0D + 137 mm, but at least 235 mm Construction subject to change.
Open the catalog to page 6Ceiling swirl diffuser DQJSL Dimensions of accessories at an extra charge: Volumetric flow meter (-VME1) Panelled cover plate (-PA...) Cylinder screw M6x40 DIN EN ISO 4762 with indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 (on site) with indentation for slotted shallowraised countersunkhead tapping screw DIN ISO 7051 pitch 4.8 (on-site) Rubber lip seal (-GD1) Detail X Available sizes Damper (-DK1) with cable adjustment (-DK2) 05/05 - 7 Construction subject to change. Version: 20.09.2019 No return possibl
Open the catalog to page 7Ceiling swirl diffuser DQJSL Technical data Pressure loss and noise level DQJSL-... with SK-R-13-Z-..., damper "CLOSED" 05/05 - 8 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 8Ceiling swirl diffuser DQJSL Maximum end velocity of jet increased horizontal multi-directional throw Vmax increased = Vmax high ind x 1.5 high-induction horizontal multi-directional throw (isothermal), increased horizontal multi-directional throw DQJSL-Z-125-... (isothermal), high-induction horizontal multi-directional throw DQJSL-Z-160-... 05/05 - 9 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 9Ceiling swirl diffuser DQJSL (isothermal), high-induction horizontal multi-directional throw DQJSL-Z-200-... (isothermal), high-induction horizontal multi-directional throw DQJSL-Z-250-... (isothermal), high-induction horizontal multi-directional throw DQJSL-Z-315-... 05/05 - 10 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 10Ceiling swirl diffuser DQJSL Critical throw (Cooling mode) high-induction horizontal multi-directional throw increased horizontal multi-directional throw = diagram value x 1.25 05/05 - 11 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 11Ceiling swirl diffuser DQJSL Maximum penetration Heating mode 05/05 - 12 Construction subject to change. Version: 20.09.2019 No return possible!
Open the catalog to page 12Temperature difference between supply air temperature and room temperature vmax Supply air temperature Room temperature Apt horizontal + vertical throw NW total air jet volume at point x total air jet volume at point x (m) = Maximum penetration in heating mode (v = 0.5 x vmax) (Pa) = Pressure loss [dB(A)] = A-weighted sound power level (kg/m3) = Density (K) = Temperature difference at point x Construction subject to change.
Open the catalog to page 13Ceiling swirl diffuser DQJSL Order code DQJSL 01 Sample DQJSL-Z-160-SB-9010-L9005-B-VM-PA000 Ceiling swirl diffuser type DQJSL with round faceplate I supply air I NW160 I faceplate made of sheet steel I faceplate painted to RAL9010 I blade colour similar to RAL9005 black I air throw pattern B I concealed mounting I without panelled cover plate I without damper Order details 01 - Type DQJSL = Ceiling swirl diffuser with round faceplate 02 - Air throw Z = Supply air 03 - Nominal size 125 = NW125 160 = NW160 200 = NW200 250 = NW250 315 = NW315 04 - Material SB = Sheet steel (standard) 05 - Paint...
Open the catalog to page 14Ceiling swirl diffuser DQJSL Order code SK 01 Plenum box, square design I for round air diffusers with round diffuser support I air diffuser DQJSLI I supply air I NW160 I with concealed mounting I galvanised sheet steel I with damper with cable I with rubber lip seal I with volumetric flow meter I without ROB model I without box insulation I standard height of plenum box I standard spigot diameter I 1 lateral spigot Order details 01 - Plenum box SK = Plenum box, square design 02 - Model R = for round air diffusers with round diffuser support 03 - Air diffuser (must be ordered separately) 13 =...
Open the catalog to page 15Ceiling swirl diffuser DQJSL 14 - Spigot diameter SDS = Standard spigot diameter xxx = Spigot diameter in mm 15 - Spigot position SO = Spigot from above S1 = 1 lateral spigot on the box (standard) S2 = 2 spigots offset by 90° S3 = 2 spigots offset by 180° S5 = 2 spigots arranged next to each other Construction subject to change.
Open the catalog to page 1632 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages