11/16 - 2 Construction subject to change. Version: 01.12.2015 No return possible!
Open the catalog to page 2Wall Induction Diffuser Model DISA-W Description Wall induction diffusers combine the flow characteristics of air diffusers with the energetic advantages of load discharge via water-based heat exchangers, allowing them to remove high thermal loads from the room while keeping the hygienically required air exchange low. Its low mounting depth makes it suitable in particular for installation in walls and ceiling panelling, providing the advantage of low mounting and maintenance costs. The wall induction diffuser is available in 4 different nozzle configurations and in lengths from 900 to 3000 mm....
Open the catalog to page 3Wall Induction Diffuser Model DISA-W Model DISA-W-H DISA-W-HT DISA-W-BO DISA-W-...-KW DISA-...-LE DISA-...-LB DISA-...-SR DISA-...-SQ DISA-...-RE DISA-...-OB DISA-...-PA DISA-...-A DISA-...-B DISA-...-C DISA-...-D DISA-...- 900 DISA-...-1200 DISA-...-1500 DISA-...-1800 DISA-...-2100 DISA-...-2400 DISA-...-2700 DISA-...-3000 DISA-...-L DISA-...-M DISA-...-R DISA-...-2E DISA-...-EL DISA-...-ER DISA-...-OE DISA-...-A DISA-...-BA 2-pipe system (standard) 4-pipe system Without register With condensate pan With individually adjustable air deflection blades Blockwise adjustable air deflection blades...
Open the catalog to page 4Wall Induction Diffuser Model DISA-W Models and dimensions Dimensions and weights _LG*_ 15 15 (1) Standard unit: housing + slot + grille and heat exchanger (empty) Construction subject to change.
Open the catalog to page 5Wall Induction Diffuser Model DISA-WWater connection Arrangement of connecting pieces Connections seen in air flow direction - 1 connection pipe (standard) - centre back (-AS1) - 2 connection pipes - left and right back (-AS3/-AS2) Connections seen in air flow direction - with 2 water connections (2-pipe system, standard) - with 4 water connections (4-pipe system) - left back (-WS1) - right back (-WS2) with 1 connecting piece (-AS1) LG Construction subject to change.
Open the catalog to page 6Wall Induction Diffuser Model DISA-W End pieces Housing position End pieces seen in air flow direction - Model with two end pieces, standard (2E) - Model with left-hand end piece (EL) - Model with right-hand end piece (ER) - Model without end pieces (OE) Connections seen in air flow direction - Housing position - right (R) - left (L) - centred (M) 11/16 - 7 Construction subject to change. Version: 01.12.2015 No return possible!
Open the catalog to page 7Wall Induction Diffuser Model DISA-W Return air connecting piece arrangement A The adjusting angle of the air deflection blades /' \ must not be more than ± 45°, in order to guarantee its function. A At an adjusting angle of the air deflection blades outside the straight air throw of up to 45°, the cooling capacity of the heat exchanger is reduced by up to 5%, and the horizontal throw is reduced. Possible selection Construction subject to change.
Open the catalog to page 8Wall Induction Diffuser Model DISA-W Accessories Band design (-BA) Rubber lip seal (-GD) At the connection piece for better tightness. Flexible connection hoses (-FA) Flexible armoured hose with stainless steel braid, oxygen diffusion layer to DIN 4726, one-sided by means of plug-in fitting 90° with stainless steel claw, support ring, 2 sealing rings (operating pressure 20 bar, test pressure 60 bar, temperature -40° to +80°) and lock washer, other side 1/2" spigot nut with flat seal. L= 500, 800 and 1200 mm. Other lengths on request. External thread flat-sealing Water connections 1/2" external...
Open the catalog to page 9Wall Induction Diffuser Model DISA-WTechnical data Performance data DISA-W-H -...-A -Cooling- NL (mm) Construction subject to change.
Open the catalog to page 10Wall Induction Diffuser Model DISA-WDISA-W-HT -...-A -Cooling- NL (mm) Construction subject to change.
Open the catalog to page 11Wall Induction Diffuser Model DISA-WDISA-W-H -...-B -Cooling- NL (mm) Construction subject to change.
Open the catalog to page 12Wall Induction Diffuser Model DISA-WDISA-W-HT -...-B -Cooling- NL (mm)
Open the catalog to page 13Wall Induction Diffuser Model DISA-WDISA-W-H -...-C -Cooling- NL (mm)
Open the catalog to page 14Wall Induction Diffuser Model DISA-WDISA-W-HT -...-C -Cooling- NL (mm)
Open the catalog to page 15Wall Induction Diffuser Model DISA-WDISA-W-H -...-D -Cooling- NL (mm) Construction subject to change.
Open the catalog to page 16Wall Induction Diffuser Model DISA-WDISA-W-HT -...-D -Cooling- NL (mm)
Open the catalog to page 17Wall Induction Diffuser Model DISA-WDISA-W-H -...-A -Heating- NL (mm) Construction subject to change.
Open the catalog to page 18Wall Induction Diffuser Model DISA-WDISA-W-HT -...-A -Heating- NL (mm)
Open the catalog to page 19Wall Induction Diffuser Model DISA-WDISA-W-H -...-B -Heating- NL (mm) Construction subject to change.
Open the catalog to page 20Wall Induction Diffuser Model DISA-WDISA-W-HT -...-B -Heating- NL (mm) Construction subject to change.
Open the catalog to page 21Wall Induction Diffuser Model DISA-WDISA-W-H -...-C -Heating- NL (mm) Construction subject to change.
Open the catalog to page 22Wall Induction Diffuser Model DISA-WDISA-W-HT -...-C -Heating- NL (mm)
Open the catalog to page 23Wall Induction Diffuser Model DISA-WDISA-W-H -...-D -Heating- NL (mm)
Open the catalog to page 24Wall Induction Diffuser Model DISA-WDISA-W-HT -...-D -Heating- NL (mm)
Open the catalog to page 25Wall Induction Diffuser Model DISA-WSound level NL (mm) Construction subject to change.
Open the catalog to page 26Construction subject to change.
Open the catalog to page 27Wall Induction Diffuser Model DISA-W Maximum end velocity of jet (isothermal) with coanda effect Flow data Model DISA-W-...-A-... Critical throw vmittel _ vmax x Length correction factors for air volumes V x KF Correction factors for the critical throw Construction subject to change.
Open the catalog to page 28Wall Induction Diffuser Model DISA-W Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Length correction factors for air volumes V x KF NL 900 1200 1500 1800 2100 2400 2700 3000 11/16 - 29 Construction subject to change. Version: 01.12.2015 No return possible!
Open the catalog to page 29Maximum end velocity of jet (isothermal) with coanda effect Construction subject to change.
Open the catalog to page 30Wall Induction Diffuser Model DISA-W Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Length correction factors for air volumes V x KF NL 900 1200 1500 1800 2100 2400 2700 3000 11/16 - 31 Construction subject to change. Version: 01.12.2015 No return possible!
Open the catalog to page 3132 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
34 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages