11/15 - 2 Construction subject to change. Version: 14.12.2015 No return possible!
Open the catalog to page 2Induction diffuser DISA-H Description Induction diffusers combine the flow characteristics of air diffusers with the energetic advantages of load discharge via water-based heat exchangers, allowing them to remove high thermal loads from the room while keeping the hygienically required air exchange low. Its low installation depth and horizontal air flow makes it suitable in particular for installation in suspended entrance halls and in suspended ceiling panellings, such as in hotels, hospitals and offices. The primary air (1) supplied from the plenum box induces secondary air in the room (2),...
Open the catalog to page 3Model DISA-H DISA-H-H DISA-H-HT DISA-...-D DISA-...-E DISA-...-F DISA-...- 900 DISA-...-1200 DISA-...-1500 Induction diffuser DISA-H Description of the equipment Construction Housing and nozzle plate - Galvanised sheet steel, with 1 or 2 connection pipes 098, 0123 (standard) or 0148 mm. Painted housing RAL 9005 (optional) - Connection pipe position: - horizontal (-H) - Arrangement of connecting pieces - 1 central connecting piece (-AS1) - 2 central connecting pieces and at the same distance (-AS2/AS3) Heat exchanger - 2-pipe system (cooling or heating) or optionally 4-pipe system (cooling and...
Open the catalog to page 4ICHAK#Induction diffuser DISA-H Models and dimensions Dimensions and weights 1 Housing 2 Heat exchanger 3 Supply air inlet L (mm) = Length (900 ,1200 and 1500) 4 Water connection 0D (mm) = diameter of the connection pipes (98, 123 and 148) 1) Standard unit: housing + heat exchanger (empty) Construction subject to change.
Open the catalog to page 5ICHAKOInduction diffuser DISA-H Arrangement of the connection pieces and water connection Number of connecting pieces with 1 connecting piece (-AS1) Number/position of the connection pipes - 1 connection pipe (standard) - centre back (-AS1) - 2 connection pipes - left and right back (-AS3/-AS2) Number/position of the water connections - with 2 water connections (2-pipe system, standard) - with 4 water connections (4-pipe system) - left back (-WS1) - right back (-WS2) Hydraulic connections DISA-H-H (2-pipe) with 2 connecting pieces (-AS2/AS3) Hydraulic connections DISA-H-HT (4-pipe) Construction...
Open the catalog to page 6The grilles are mounted with concealed mounting VM11. Accessories Rubber lip seal (-GD) At the connection piece for better tightness. Volumetric flow measuring tube (-MR) The supplied primary volumetric flow can be simply checked by checking the static pressure with a Pa meter. The measurement is taken in the supply air area. Flexible connection hoses (-FA) Flexible armoured hose with stainless steel braid, oxygen diffusion layer to DIN 4726, one-sided by means of plug-in fitting 90° with stainless steel prong, support ring, 2 sealing rings (operating pressure 20 bar, test pressure 60 bar, temperature...
Open the catalog to page 7Induction diffuser DISA-HTechnical data Performance data DISA-H-H -...-D -Cooling- L (mm)
Open the catalog to page 8Induction diffuser DISA-HDISA-H-H -...-E -Cooling- L (mm)
Open the catalog to page 9Induction diffuser DISA-HDISA-H-H -...-F -Cooling- L (mm) Construction subject to change.
Open the catalog to page 10Induction diffuser DISA-HDISA-H-H -...-D -Heating- L (mm) Construction subject to change.
Open the catalog to page 11Induction diffuser DISA-HDISA-H-H -...-E -Heating- L (mm) Construction subject to change.
Open the catalog to page 12Induction diffuser DISA-HDISA-H-H -...-F -Heating- L (mm) Construction subject to change.
Open the catalog to page 13Induction diffuser DISA-H Sound level Sound pressure level (room damping -8 dB)11/15 - 14 Version: 14.12.2015 L (mm) Construction subject to change.
Open the catalog to page 14“HAk#Induction diffuser DISA-HFlow data DISA-H-D (with grille) Critical throw Maximum end velocity of jet (isotherm) with coanda effect Correction factors for the critical throw Length correction factors for air volumes Critical jet path - Correction factors for PA grille Maximum end velocity of jet - Correction factors for PA grille PA-1 Blade position straight PA-1 Blade position straight Critical jet path - Correction factors for IB grille Maximum end velocity of jet - Correction factors for IB grille IB-1 Blade position straight IB-1 Blade position straight Version: 14.12.2015 Construction...
Open the catalog to page 15Induction diffuser DISA-H Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Correction factors for temperature ratios TV and Induction ratio Length correction factors for air volumes Maximum end velocity of jet - Correction factors for PA grille Induction ratios and temperature ratios -Correction factors for PA grille PA-1 Blade position straight Maximum end velocity of jet - Correction factors for IB grille PA-1 Blade position straight IB-1 Blade position straight Induction ratios and temperature ratios -Correction factors...
Open the catalog to page 16“HAk#Induction diffuser DISA-HDISA-H-D (without grille) Critical throw Length correction factors for air volumes VZU x KF Correction factors for the critical throw Construction subject to change.
Open the catalog to page 17Induction diffuser DISA-H Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Length correction factors for air volumes VZU x KF NL 11/15 - 18 Construction subject to change. Version: 14.12.2015 No return possible!
Open the catalog to page 18“HAk#Induction diffuser DISA-HDISA-H-E (with grille) Critical throw Maximum end velocity of jet (isotherm) with coanda effect Correction factors for the critical throw Length correction factors for air volumes VZU x KF Critical jet path - Correction factors for PA grille Maximum end velocity of jet - Correction factors for PA grille IB-1 Blade position straight Construction subject to change.
Open the catalog to page 19Maximum end velocity of jet (isothermal) at floor level Temperature ratio / induction ratio secondary slot - primary air only Correction factors for temperature ratios TV and Induction ratio Length correction factor for air volumes Maximum end velocity of jet - Correction factors for PA grille Induction ratios and temperature ratios -Correction factors for PA grille PA-1 Blade position straight PA-1 Blade position straight Maximum end velocity of jet - Correction factors for IB grille IB-1 Blade position straight Induction ratios and temperature ratios -Correction factors for IB grille IB-1 Blade...
Open the catalog to page 2032 Pages
28 Pages
9 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
18 Pages
6 Pages
23 Pages
23 Pages
43 Pages
17 Pages
16 Pages
18 Pages
6 Pages
6 Pages
11 Pages
29 Pages
18 Pages
15 Pages
9 Pages
79 Pages
15 Pages
25 Pages
26 Pages
17 Pages
18 Pages
11 Pages
22 Pages
26 Pages
37 Pages
10 Pages
46 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
38 Pages
6 Pages
16 Pages
23 Pages
19 Pages
20 Pages
15 Pages
31 Pages
29 Pages
5 Pages
27 Pages
8 Pages
23 Pages
7 Pages
34 Pages
13 Pages
4 Pages
16 Pages
16 Pages
13 Pages
11 Pages
14 Pages
38 Pages
34 Pages
32 Pages
51 Pages
29 Pages
40 Pages
35 Pages
17 Pages
16 Pages
38 Pages
20 Pages
43 Pages
24 Pages
11 Pages
33 Pages
19 Pages
18 Pages
13 Pages
16 Pages
16 Pages
21 Pages
23 Pages
17 Pages
15 Pages
12 Pages
10 Pages
17 Pages
17 Pages
18 Pages
11 Pages
11 Pages
15 Pages
7 Pages
30 Pages
23 Pages
12 Pages
25 Pages
23 Pages
20 Pages
13 Pages
25 Pages
7 Pages
13 Pages
32 Pages
19 Pages
19 Pages
21 Pages
15 Pages
12 Pages
32 Pages
6 Pages
17 Pages
11 Pages
7 Pages
29 Pages
4 Pages
4 Pages
4 Pages
10 Pages
5 Pages
6 Pages
52 Pages
6 Pages
27 Pages
27 Pages
26 Pages
19 Pages
26 Pages
20 Pages
52 Pages
15 Pages
7 Pages
15 Pages
24 Pages
4 Pages
11 Pages
5 Pages
31 Pages
10 Pages
7 Pages
41 Pages
6 Pages
10 Pages
38 Pages
24 Pages
15 Pages
16 Pages
16 Pages
13 Pages
7 Pages
9 Pages
8 Pages
35 Pages
60 Pages
40 Pages
6 Pages
14 Pages